Honeywell LYNXR Series, LYNXR-EN Trouble Conditions, Fault and Battery Displays, Other Displays

Page 52

System Operation

Trouble Conditions

The word “FAULT” on the keypad’s display, accompanied by a rapid “beeping” at the keypad, indicates that there is a trouble condition in the system. Pressing any key can silence the audible warning sound. Instruct users to call for service immediately upon seeing any of the following messages.

“Fault” and “Battery” Displays

“FAULT” and one or more zone numbers indicates that a problem exists with the displayed zone(s) and requires attention. After correcting the problem, the display can be cleared by entering the security code plus the OFF key twice.

The fault condition may also be caused by some change in the environment that prevents the built-in receiver from receiving signals from a particular wireless sensor.

“LOW BAT” with no zone number indicates that the system’s backup battery is weak.

“LOW BAT” with a zone number and a once-per-45 seconds “beeping” at the keypad indicates that a low battery condition exists in the wireless sensor displayed (zone “00” indicates a wireless button/keypad). If the battery is not replaced within 30 days, a “FAULT” display may occur.

Fault Zone 93”, along with a flashing “AC” and a once per 45-seconds “beeping” at the keypad indicates a loss of AC power to the 5842 Wireless Dialer (if this feature is supported by the Wireless Dialer being installed).

Fault Zone 93”, along with a single beep indicates that setup information from the 5842 Wireless Dialer has not been properly received.

Power Failure

If there is no display at all, and both indicators are not lit, operating power for the system has stopped and the system is inoperative.

If the display is lit and the AC display is off, the system is operating on battery power only.

During an AC power loss, the backlighting will turn off and the indicators will flicker slightly to minimize deep discharge of the battery.

Other Displays

dI = Busy-Standby: Displayed upon power-up. After approximately 1 minute* the green “READY” LED should light. If the “dI” remains displayed for more than 1 minute, the system is disabled.

*To bypass the 1-minute delay, press [#] + [0]. Important: Do not try to bypass 1 minute delay before “dI” is displayed!

CC= Modem Comm: The system is communicating with the central station for change of function or status verification.

FC = Comm. Failure: A communication failure has occurred. This message clears only when the system is subsequently armed.

90 = RF Jam: The system has detected an RF jamming condition or excessive interference.

93 = Wireless Dialer: Tamper (alarm or trouble), phone line cut, loss of supervision, low battery, or AC power loss*.

*If supported by the 5842 Wire Dialer that is installed.

PH = Speaker Phone Mode: The system is in Speaker Phone mode.

PC = Phone Control: The remote Phone Control feature is active.

--Displayed when entering programming mode if a 5842 Wireless Dialer is enabled.

–52–

Image 52
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents System Features Hardwire zoneHour backup Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Overview Wiring ConnectionsWiring Connections Full Line Seizure Connections This System AC Power and Backup Battery AC Power and Rechargeable Backup Battery75 to 150 feet 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionInstalling Wireless Zones General InformationHouse Identification Transmitter SupervisionTransmitter Battery Life Using the Transmitter Sniffer ModeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Loading Factory Defaults Exiting Program ModeMechanics of Programming General Programming InformationZone Response Type Definitions TypeZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Follow Me Reminder Phone Number Phone System SelectReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Enabling the Wireless Dialer Enhanced Zone Programming ModeDevice Programming Menu Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable the wireless dialer Enable trouble reportsEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone number Zone typeReport code Input typeDelete zone parameters Enroll modeConfirmation Voice descriptor Serial numberDescriptor Device Programming Menu Mode Programming Options DefinedStart by Event Start by Zone Type or System OperationProgramming Powerline Carrier Devices Upon Restore of a Zone ListStop Upon a Zone Type or System OperationPowerline Carrier Device ProgrammingDevice number Device actionZone List Menu Mode 00 = exit Sequential mode Enhanced Sequential ModeEnter the 2-digit zone number IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexAssign custom voice descriptors Record Custom Voice DescriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsSecond Central Station Account Number Front Basement Back SlidingPatio ToenrollPendant Type To Enter Expert Programming Mode TemplateRemote Programming Information Remote Programming/Control DownloadingEquipment required to download to a system at the premises Remote Programming Advisory Notes Security Codes System OperationPanic Keys Volume Control Keypad FunctionsMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Operator Commands Alarm Audio Verification Two-Way Voice FeatureActivation Follow Me System Announcement Feature Powerline Carrier Devices e.g. X-10 devicesExit Error Alarm Displays If programmedTrouble Conditions Fault and Battery DisplaysOther Displays Test Mode Testing the SystemArmed System Test System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemSpecifications LYNXR-Series Security ControlsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Start Stop Device NumberEvent System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.