System Operation

Keypad Functions

The keypad allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones. Zone and system conditions (alarm, trouble, bypass) are displayed in the display window. When an alarm occurs, keypad sounding and external sounding will occur, and the zone(s) in alarm will be displayed on the keypad. Pressing any key will silence the keypad sounder for 10 seconds (only once). Disarming the system will silence both keypad and external sounders. When the system is disarmed, any zones that were in an alarm condition during the armed period will be displayed (memory of alarm). To clear this display, simply repeat the disarm sequence (enter the security code and press the OFF key). The keypad also features chime annunciation, and 3 panic key pairs for silent, audible, fire or personal emergency alarms. These keys can notify the central station of an alarm condition, if that service is connected. A summary of system functions is provided below for more detailed information refer to the User’s Manual.

Security Functions (Empty boxes represent the user’s security code)

Checking system status:

 

 

 

(high level messages); press

 

 

 

again for secondary messages

STATUS

STATUS

To arm in STAY mode:

 

 

+

 

 

 

 

 

 

 

(or installer code + [3])

 

 

 

STAY

To restart exit delay:

 

 

(applies only if system is armed in Stay mode)

 

STAY

To arm in AWAY mode:

 

 

+

 

 

 

 

 

(or installer code + [2])

 

 

AWAY

To arm with NO DELAY:

 

 

+

 

 

 

 

 

or

 

 

+

 

 

 

 

 

 

AWAY

 

STAY

NO DELAY

To arm if Quick Arm is programmed:

 

 

 

 

 

or

 

 

 

(hold down for at least 2 seconds)

AWAY

 

 

STAY

To disarm the system and silence alarms:

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

To bypass a zone(s):

 

 

+

 

 

 

 

 

+ 2-digit zone number(s)

 

 

 

BYPASS

To turn Chime mode on or off:

 

 

+

 

 

 

 

FUNCTION

 

 

CHIME

Message Center

To record a message: FUNCTION + RECORD To stop recording before end of 20 seconds:

To play back a message:

 

 

 

+

 

 

 

 

FUNCTION

PLAY

To skip a message: []

 

 

 

 

 

 

 

To delete all messages:

 

 

+

 

 

FUNCTION

 

DELETE

Volume Control

 

 

NOTE

 

 

If a 5827 Wireless keypad has been installed, it cannot be used to

 

 

activate message playback/recording, programming the real time clock

OFF

 

 

or scheduling remotely. In this case, you must use the master keypad on

 

 

the control panel to perform these functions.

 

 

 

(during message replay)

To adjust message playback/system announcement volume:

 

 

 

 

+

 

 

FUNCTION

VOLUME

To mute system announcements:

 

+

 

 

 

+

 

 

 

 

FUNCTION

 

VOLUME

 

 

OFF

 

 

To restore/unmute announcement & volume:

 

+

 

 

+ [3] or [6]

FUNCTION

 

VOLUME

+ [3] or [6]

Other Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To set the time and date:

+

 

 

 

 

 

 

+ [63]

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

To set the scheduling:

+

 

 

 

 

 

 

+ [64]

 

 

 

 

 

 

 

 

 

 

FUNCTION

 

To activate or deactivate X-10 devices 1-6:

 

 

+

 

 

or

 

 

 

+ device number

FUNCTION

LIGHTS ON

LIGHTS OFF

To activate or deactivate X-10 devices 7 & 8:

 

 

 

 

+

 

+

 

or

 

 

 

 

 

FUNCTION

LIGHTS ON

LIGHTS OFF

To add a user code:

*+

 

+ user number + user’s code (*master code)

CODE

+ dev. No.

To delete a user code (except Master Code):

*+

 

+ user number (* master code)

CODE

To turn Test mode on:

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST

 

 

 

 

 

 

 

 

To turn Test mode off:

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

To use the defined AUX function: Press and hold

 

 

key 2 secs (4 beeps) +

 

AUX

 

To define AUX function:

+

 

 

 

+

 

 

+ action separated by +

 

terminated by +

 

FUNCTION

AUX

AUX

To send message to pager: Press and hold

 

key 2 seconds (4 beeps)

 

 

 

 

AUX

 

 

 

 

To program Follow Me Announcement telephone number:

+

 

+ [65]

FUNCTION

 

 

 

 

 

 

 

 

 

 

 

–48–

 

 

 

 

AUX

+

AUX

Image 48
Contents Ademco Lynxr Series Security Systems Recommendations for Smoke and Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents System Features Hardwire zoneHour backup Two-way voice communication Speaker phone operationMounting the Control Desktop MountingWiring Connections Wiring OverviewWiring Connections Full Line Seizure Connections This System AC Power and Backup Battery AC Power and Rechargeable Backup Battery75 to 150 feet 150 to 300 feetHours minimum Approximately 1-hour before battery depletion Hours minimum At least 1-hour before battery depletionInstalling Wireless Zones General InformationHouse Identification Transmitter SupervisionTransmitter Battery Life Using the Transmitter Sniffer ModeEnter Installer code 4112 + # + Go/No Go Test ModeSetting DIP Switches on the 5800RL and 5827 Transmitters Loading Factory Defaults Exiting Program ModeMechanics of Programming General Programming InformationZone Response Type Definitions TypeZone Not Used Type Entry/Exit Burglary #1 Type 02 Entry/Exit Burglary #25806/5807/5808 Defaults where applicable are Indicated in Text Data Field DescriptionsDialer Programming Fields 43Follow Me Reminder Phone Number Phone System SelectReport Format for Primary/Secondary Split/Dual ReportingSystem Status and Restore Report Codes Programming 59 76 Restore Report Codes System Status Report CodesRestore Report Codes Download Information 94 Enabling the Wireless Dialer Enhanced Zone Programming ModeDevice Programming Menu Mode Zone Lists for Menu ModeEnabling the 5842 Wireless Dialer Wireless Dialer SetupEnable the wireless dialer Enable trouble reportsEnable back-up reporting Response to phone line tamperEnhanced Zone Programming Mode Zone number Zone typeReport code Input typeEnroll mode Delete zone parametersConfirmation Serial number Voice descriptorDescriptor Device Programming Menu Mode Programming Options DefinedStart by Event Start by Zone Type or System OperationProgramming Powerline Carrier Devices Upon Restore of a Zone ListStop Upon a Zone Type or System OperationPowerline Carrier Device ProgrammingDevice number Device actionZone List Menu Mode Enhanced Sequential Mode 00 = exit Sequential modeEnter the 2-digit zone number IA LC = copy the previous serial number entry from the bufferDelete serial number Assign Zone Voice Descriptors Assign zone voice descriptorsAssign Zone Voice Descriptor Voice Vocabulary IndexRecord Custom Voice Descriptors Assign custom voice descriptorsCustom descriptor number Voice Prompt Programming Voice Prompt Programming Keypad FunctionsSecond Central Station Account Number Front Basement Back SlidingPatio ToenrollPendant Type To Enter Expert Programming Mode TemplateRemote Programming/Control Downloading Remote Programming InformationEquipment required to download to a system at the premises Remote Programming Advisory Notes System Operation Security CodesPanic Keys Volume Control Keypad FunctionsMessage Center Other FunctionsRemote Phone Control Feature Remote Phone Control FeatureSpeaker Phone Operation LYNXR-EN Only Alarm Audio Verification Two-Way Voice Feature Operator CommandsActivation Follow Me System Announcement Feature Powerline Carrier Devices e.g. X-10 devicesExit Error Alarm Displays If programmedFault and Battery Displays Trouble ConditionsOther Displays Testing the System Test ModeArmed System Test System Communication Communication OverviewContact ID Event Codes Report +1/4+1 Standard +1/4+1 ExpandedTroubleshooting Guide S T E M i n c l u d i n g W i r e l e s sN T R O L O K E D E T E C T O RPLEASE, before you call Technical Support, be sure you Read the InstructionsRegulatory Agency Statements UL Notice This is a Grade a residential systemSpecifications LYNXR-Series Security ControlsElectrical CommunicationLYNXR/LYNXR24 Programming Default Tables LYNXR-EN Programming Default Tables Zone ASSIGNMENT/ALARM Report Codes for Table Start Stop Device NumberEvent System OperationIndex 20, 61Exit Delay Serial Number Page Limitations of this Alarm System Limited Warranty Police With System‡K5963V3oŠ

LYNXR Series, LYNXR-EN specifications

The Honeywell LYNXR Series, particularly the LYNXR-EN model, represents a pinnacle of advanced security technology designed for residential and small business applications. This all-in-one wireless security system is lauded for its innovative features, ease of use, and powerful performance, making it a top choice among users seeking enhanced security solutions.

One of the standout features of the LYNXR-EN is its user-friendly touchscreen interface. The large, intuitive display allows for straightforward navigation, enabling users to arm or disarm the system, check status, and receive alerts with just a few taps. This ease of use is complemented by programmable quick access keys, which allow users to personalize their experience according to their security requirements.

Additionally, the LYNXR-EN is designed with flexibility in mind. It supports a wide range of wireless sensors and devices, facilitating comprehensive coverage for homes or small businesses. Users can integrate door and window contacts, motion detectors, glass break sensors, and more, ensuring that every entry point is monitored. The system can accommodate up to 48 wireless zones, allowing for extensive security applications without the clutter of wires.

Technologically, the LYNXR-EN leverages advanced RF technology, enhancing the reliability of communication between the panel and sensors. This feature minimizes the risk of interference and ensures consistent performance even in challenging environments. Along with this robust connectivity, the system offers dual-path communication capabilities, enabling both IP and cellular reporting. This redundancy ensures that alerts are promptly sent to the monitoring center and mobile devices, providing peace of mind to users.

Moreover, the LYNXR-EN can be easily integrated with smart home technology. It is compatible with various smart devices, allowing users to control lighting, thermostats, and other home automation features from a single platform. This integration not only enhances convenience but also optimizes energy efficiency.

The LYNXR-EN also includes a built-in battery backup, ensuring that the system remains operational during power outages. This is a crucial feature for maintaining security when it is needed most. Additionally, users can set up customizable alerts and notifications, allowing them to stay informed of any unusual activity in real-time.

In summary, the Honeywell LYNXR Series, especially the LYNXR-EN model, combines advanced technology with user-friendly design to deliver a versatile and robust security solution. Its wireless capabilities, comprehensive sensor support, smart home integration, and reliable communication make it a prominent choice in the ever-evolving realm of security systems.