Bosch Appliances D1265 Perimeter Partial CMD +, Partially Turn On the Perimeter Description

Page 27

D1265 Owner's Manual Part II: System Commands

If you prefer, you might use the function list in place of Steps 2 and 3 to initiate this function.

Press the Menu button to enter the function list.

Press the Next button repeatedly.

When you reach the Watch Mode button, press it.

4.The display briefly shows Watch Mode is now off.

The display returns to show idle text.

Perimeter Partial (CMD + 8)

Partially Turn On the Perimeter

Description

This function is used to turn on the perimeter of your building while selected portions of the perimeter remain turned off. Perimeter points that are not secure (faulted) when this function is entered are automatically bypassed and are not included in the system. This function will not turn on the interior of your building. Entry/exit delays are provided with this arming command.

Use this function in residential systems to turn on the front of your house while the interior and the rear perimeter doors are left turned off, giving you freedom of movement between the house and patio.

In commercial systems, when you need access to the large overhead doors to receive deliveries, using this function allows you to keep the rest of the building perimeter armed.

Using Perimeter Partial

1.Ensure the display shows disarmed idle text.

2.Press the CMD button. The display shows *System Command*

.

3.Press the 6 button.

If you prefer, you might use the function list in place of Steps 2 and 3 to initiate this function.

Press the Menu button to enter the function list.

Press the Next button repeatedly.

When you reach the Perimeter Arm Part button, press it.

Bosch Security Systems, Inc. 9/10 F01U169130-02

27

Image 27
Contents D1265 Page Contents Bosch Security Systems, Inc /10 F01U169130-02 Figures Your Keypad IntroductionUsing the keypad Command Enter buttonsPoints Non-Fire Points Fire PointsYour Custom Display Priority of Events View Faulted or Bypassed PointsTo Scroll Faulted or Bypassed Points Keypad Quiets for Button pressesSilencing Fire Alarms Fire AlarmsSilencing Fire Trouble and Fire Supervisory conditions Burglary AlarmsSilencing Burglary Alarms Fire Trouble and Fire Supervisory EventsSilencing an Alarm Non-Fire Trouble and Supervisory EventsSpecial System Trouble Display How Your System Reports Alarms Part II System Commands To Turn Your Security System On Arm Passcode Protected Commands and FunctionsTurning the System On Arming Turning the System Off DisarmingTurning On the System Arming With Doors or Windows Open Turning On the System Arming With a Duress PasscodeBosch Security Systems, Inc /10 F01U169130-02 Using Master Arm Master Arm CMD +Description Master Arming all Areas Perimeter Instant CMD + Turn On the Perimeter With No Delays DescriptionUsing Perimeter Instant Master Arm Instant CMD + 1 +Perimeter Delay CMD + Turn On the Perimeter With Delays DescriptionUsing Perimeter Delay Silence Trouble Sound/Clear Trouble Display CMD + View Alarm Memory CMD + 4 +Using CMD Using View Alarm Memory Walk Test CMD + 4 + Using Walk TestUsing Reset Sensors Reset Sensors CMD + 4 +Watch Mode CMD + Using Watch ModeEntering Watch Mode Using Perimeter Partial Perimeter Partial CMD +Partially Turn On the Perimeter Description Special Alerts CMD + 7 and CMD + Using Command Terms Used in This Section Advanced CommandsBypass a Point CMD + Using Bypass a PointBosch Security Systems, Inc /10 F01U169130-02 Unbypass a Point CMD + 0 + Using Unbypass a PointSend Report CMD + 4+1 or 4+2 Using Send ReportFor systems without a phone number Remote Program CMD + 4 +For systems with a network connection For systems with a phone number configuredChange Time/Date CMD + 4 + Set Date button disappears when the first digit is entered Door Status Using Door ControlDoor Control CMD + 4 + Cycle DoorSecure Door Unlock DoorAccess Level Change Display CMD + 4 + Extend Closing CMD + 5 +Show Continuous Time/Date Bosch Security Systems, Inc /10 F01U169130-02 Chg Skeds CMD + 5 + Using Chg SkedsSked Table Delete User CMD + 5 + Using Change Passcode Change Relay CMD + 5 +Change Passcode CMD + 5 + Add/Change User CMD + 5 + Page User 3 is used here as an example Add/Change PasscodeBosch Security Systems, Inc /10 F01U169130-02 Add/Change Level Adding/Changing a User’s Name Add/Change Card Add/Change Sub-User ID Default Text CMD + 5 + Using Fire TestFire Test CMD + 5 + Bosch Security Systems, Inc /10 F01U169130-02 Display Rev CMD + 5 + Service Menu 9 + 9 + EnterUsing View Log Using Print LogUsing Display Revision Using Default Text Keypad Setup MenuView Area Status Working with Multiple Areas from a Single KeypadScreen Area Definitions View Point StatusMove To Area CMD + 5 + Turning On the SystemTurning on Selected Areas Turning on Multiple Areas with a Passcode Faulted Points in Other AreasTurning on All or Selected Areas Turn On the Entire System Without DelaysTurning Off the System Turning Off Multiple Areas with a PasscodeTurning Off Multiple Areas with Disarm All Turning Off Selected Areas User Interface Supplementary Information for Adding PasscodesUser Authority Levels Passcode WorksheetAuthority Levels User Passcode Worksheet User 000 to ### User Passcode Worksheet User 039 to Bosch Security Systems, Inc /10 F01U169130-02 User Area Authority ### Passcode Group User Name Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 115 Site Card Data User Area Authority ### Passcode Group Bosch Security Systems, Inc /10 F01U169130-02 Bosch Security Systems, Inc /10 F01U169130-02 Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 User Area Authority ### Passcode Group Bosch Security Systems, Inc /10 F01U169130-02 User Passcode Worksheet Blank User Token Worksheet Blank Security System LimitationsView Fire Safety and EvacuationStandard Displays System Trouble Displays Hour Point Bypass Service PrinterService D9210 Service Zonex Bus 1 orSecurity System Glossary Maintenance and Service How to Clean the KeypadYour Alarm Company Bosch Security Systems, Inc /10 F01U169130-02 Bosch Security Systems, Inc Perinton Parkway Fairport, NY