Standard Displays

Your keypad uses standard and custom displays to show the status of the security system. Many standard displays are described below. Your system might not use all of them. Descriptions of your custom text follow.

*System Command*

Shows when you press the CMD button. The system is waiting for you to enter a one or two digit number to complete the command.

Entry Delay/Enter Passcode to Disarm

When the system is turned on, entering through a delay door starts entry delay time.

The keypad emits a tweedle tone and alternates between Enter Passcode and press the ENTER button to disarm and AREA # AREA TEXT is in entry delay.

**No Authority**

The system will not recognize the passcode entered.

Perimeter On Delayed

Indicates that the perimeter is armed (turned on) with entry/exit delay time and shows Perimeter On Delayed. (Refer to Perimeter Delay (CMD + 3) on page 22).

Perimeter Instant

Indicates that the perimeter is armed (turned on) without entry/exit delay time and shows Perimeter On Instant. (Refer to Turn On the Perimeter With No Delays on page 21.).

You must turn off the system before entry delay time expires to avoid creating an alarm event.

Exit Now

Arming your system starts exit delay time. The keypad emits a repeating beep tone and shows Exit Now!.

Area must be disarmed first

Indicates that the function requested can only be performed when the area is disarmed. Disarm the area to perform the function.

86

Bosch Security Systems, Inc. 9/10 F01U169130-02

Image 86
Contents D1265 Page Contents Bosch Security Systems, Inc /10 F01U169130-02 Figures Introduction Your KeypadPoints Using the keypadCommand Enter buttons Fire Points Non-Fire PointsYour Custom Display Keypad Quiets for Button presses View Faulted or Bypassed PointsTo Scroll Faulted or Bypassed Points Priority of EventsFire Alarms Silencing Fire AlarmsFire Trouble and Fire Supervisory Events Burglary AlarmsSilencing Burglary Alarms Silencing Fire Trouble and Fire Supervisory conditionsSpecial System Trouble Display Silencing an AlarmNon-Fire Trouble and Supervisory Events How Your System Reports Alarms Part II System Commands Turning the System Off Disarming Passcode Protected Commands and FunctionsTurning the System On Arming To Turn Your Security System On ArmTurning On the System Arming With a Duress Passcode Turning On the System Arming With Doors or Windows OpenBosch Security Systems, Inc /10 F01U169130-02 Description Using Master ArmMaster Arm CMD + Master Arming all Areas Master Arm Instant CMD + 1 + Turn On the Perimeter With No Delays DescriptionUsing Perimeter Instant Perimeter Instant CMD +Using Perimeter Delay Perimeter Delay CMD +Turn On the Perimeter With Delays Description Using View Alarm Memory View Alarm Memory CMD + 4 +Using CMD Silence Trouble Sound/Clear Trouble Display CMD +Using Walk Test Walk Test CMD + 4 +Reset Sensors CMD + 4 + Using Reset SensorsEntering Watch Mode Watch Mode CMD +Using Watch Mode Partially Turn On the Perimeter Description Using Perimeter PartialPerimeter Partial CMD + Special Alerts CMD + 7 and CMD + Using Command Advanced Commands Terms Used in This SectionUsing Bypass a Point Bypass a Point CMD +Bosch Security Systems, Inc /10 F01U169130-02 Using Unbypass a Point Unbypass a Point CMD + 0 +Using Send Report Send Report CMD + 4+1 or 4+2Remote Program CMD + 4 + For systems without a phone numberFor systems with a phone number configured For systems with a network connectionChange Time/Date CMD + 4 + Set Date button disappears when the first digit is entered Cycle Door Using Door ControlDoor Control CMD + 4 + Door StatusUnlock Door Secure DoorAccess Level Show Continuous Time/Date Change Display CMD + 4 +Extend Closing CMD + 5 + Bosch Security Systems, Inc /10 F01U169130-02 Using Chg Skeds Chg Skeds CMD + 5 +Sked Table Delete User CMD + 5 + Change Passcode CMD + 5 + Using Change PasscodeChange Relay CMD + 5 + Add/Change User CMD + 5 + Page Add/Change Passcode User 3 is used here as an exampleBosch Security Systems, Inc /10 F01U169130-02 Add/Change Level Adding/Changing a User’s Name Add/Change Card Add/Change Sub-User ID Fire Test CMD + 5 + Default Text CMD + 5 +Using Fire Test Bosch Security Systems, Inc /10 F01U169130-02 Service Menu 9 + 9 + Enter Display Rev CMD + 5 +Using Display Revision Using View LogUsing Print Log Keypad Setup Menu Using Default TextWorking with Multiple Areas from a Single Keypad View Area StatusView Point Status Screen Area DefinitionsTurning on Selected Areas Move To Area CMD + 5 +Turning On the System Faulted Points in Other Areas Turning on Multiple Areas with a PasscodeTurn On the Entire System Without Delays Turning on All or Selected AreasTurning Off Multiple Areas with Disarm All Turning Off the SystemTurning Off Multiple Areas with a Passcode Turning Off Selected Areas Passcode Worksheet Supplementary Information for Adding PasscodesUser Authority Levels User InterfaceAuthority Levels User Passcode Worksheet User 000 to ### User Passcode Worksheet User 039 to Bosch Security Systems, Inc /10 F01U169130-02 User Area Authority ### Passcode Group User Name Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 115 Site Card Data User Area Authority ### Passcode Group Bosch Security Systems, Inc /10 F01U169130-02 Bosch Security Systems, Inc /10 F01U169130-02 Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 User Area Authority ### Passcode Group Bosch Security Systems, Inc /10 F01U169130-02 User Passcode Worksheet Blank Security System Limitations User Token Worksheet BlankFire Safety and Evacuation ViewStandard Displays System Trouble Displays Service Zonex Bus 1 or Service PrinterService D9210 Hour Point BypassSecurity System Glossary Your Alarm Company Maintenance and ServiceHow to Clean the Keypad Bosch Security Systems, Inc /10 F01U169130-02 Bosch Security Systems, Inc Perinton Parkway Fairport, NY