Although having a security system might make you eligible for reduced insurance premiums, the system is no substitute for insurance. Warning devices cannot compensate you for loss of life or property.

Fire Safety and Evacuation

Residential fire is a leading cause of accidental death. Most fire related deaths occur at night when occupants suffocate in their sleep from smoke and toxic gases, rather than from burns. To help reduce this risk, the following program should be implemented:

1.Minimize fire hazards. Smoking in bed, cleaning with flammable liquids such as gasoline, leaving children home alone, and using unsafe holiday decorations are some of the common causes of household fire.

2.Install a fire alarm system. The primary purpose of this system is to protect lives by giving the earliest possible warning of danger.

3.A smoke detector should be provided to protect each sleeping area in a home (Figure 2 and Figure 3).

Figure 2: Smoke Detector Locations (Plan View)

 

2

4

 

5

3

 

 

 

 

1

 

 

 

 

 

 

1

 

6

 

3

 

3

 

 

 

 

1 -

Smoke Detector

 

4 -

Dining Room

2 -

TV Room

 

5 -

Kitchen

 

3 -

Bedroom

 

6 -

Living Room

Figure 3: Smoke Detector Locations (Elevation

 

View)

 

 

 

 

 

2

 

1

 

2

1

 

2

 

 

 

1 -

Smoke Detector

 

2 -

Bedroom

4.Practice an escape plan. Because there might be very little time between detection of a fire and the time it becomes deadly, it is important that every member of the family understand how to quickly evacuate according to the plan.

5.Plan both primary and alternate escape routes. Since stairwells and hallways might be blocked during a fire, exiting through a bedroom window must be a part of the escape plan. If the sleeping area is above the ground floor, install a means of safely descending outside the building if one will not already exist.

6.As a part of this plan, all family members should arrange to meet at a location away from the house (such as a neighbor’s house) so you know that everyone is accounted for.

Figure 4: Escape Route

 

 

 

 

 

 

 

 

2

 

5

4

 

3

3

 

 

7

 

 

 

 

6

1

 

 

3

 

 

 

 

 

1 -

Fire

 

5 -

Dining Room

2 -

Escape Routes

6 -

Living Room

3 -

Bedroom

 

7 -

Smoke Detector

4 -

Kitchen

 

 

 

 

7.If it is determined that the alarm was accidentally sounded, the bell should be silenced, the detectors reset, and your security company notified immediately that there is no emergency situation.

Bosch Security Systems, Inc. 9/10 F01U169130-02

85

Image 85
Contents D1265 Page Contents Bosch Security Systems, Inc /10 F01U169130-02 Figures Your Keypad IntroductionCommand Enter buttons Using the keypadPoints Non-Fire Points Fire PointsYour Custom Display To Scroll Faulted or Bypassed Points View Faulted or Bypassed PointsKeypad Quiets for Button presses Priority of EventsSilencing Fire Alarms Fire AlarmsSilencing Burglary Alarms Burglary AlarmsFire Trouble and Fire Supervisory Events Silencing Fire Trouble and Fire Supervisory conditionsNon-Fire Trouble and Supervisory Events Silencing an AlarmSpecial System Trouble Display How Your System Reports Alarms Part II System Commands Turning the System On Arming Passcode Protected Commands and FunctionsTurning the System Off Disarming To Turn Your Security System On ArmTurning On the System Arming With Doors or Windows Open Turning On the System Arming With a Duress PasscodeBosch Security Systems, Inc /10 F01U169130-02 Master Arm CMD + Using Master ArmDescription Master Arming all Areas Using Perimeter Instant Turn On the Perimeter With No Delays DescriptionMaster Arm Instant CMD + 1 + Perimeter Instant CMD +Turn On the Perimeter With Delays Description Perimeter Delay CMD +Using Perimeter Delay Using CMD View Alarm Memory CMD + 4 +Using View Alarm Memory Silence Trouble Sound/Clear Trouble Display CMD +Walk Test CMD + 4 + Using Walk TestUsing Reset Sensors Reset Sensors CMD + 4 +Using Watch Mode Watch Mode CMD +Entering Watch Mode Perimeter Partial CMD + Using Perimeter PartialPartially Turn On the Perimeter Description Special Alerts CMD + 7 and CMD + Using Command Terms Used in This Section Advanced CommandsBypass a Point CMD + Using Bypass a PointBosch Security Systems, Inc /10 F01U169130-02 Unbypass a Point CMD + 0 + Using Unbypass a PointSend Report CMD + 4+1 or 4+2 Using Send ReportFor systems without a phone number Remote Program CMD + 4 +For systems with a network connection For systems with a phone number configuredChange Time/Date CMD + 4 + Set Date button disappears when the first digit is entered Door Control CMD + 4 + Using Door ControlCycle Door Door StatusSecure Door Unlock DoorAccess Level Extend Closing CMD + 5 + Change Display CMD + 4 +Show Continuous Time/Date Bosch Security Systems, Inc /10 F01U169130-02 Chg Skeds CMD + 5 + Using Chg SkedsSked Table Delete User CMD + 5 + Change Relay CMD + 5 + Using Change PasscodeChange Passcode CMD + 5 + Add/Change User CMD + 5 + Page User 3 is used here as an example Add/Change PasscodeBosch Security Systems, Inc /10 F01U169130-02 Add/Change Level Adding/Changing a User’s Name Add/Change Card Add/Change Sub-User ID Using Fire Test Default Text CMD + 5 +Fire Test CMD + 5 + Bosch Security Systems, Inc /10 F01U169130-02 Display Rev CMD + 5 + Service Menu 9 + 9 + EnterUsing Print Log Using View LogUsing Display Revision Using Default Text Keypad Setup MenuView Area Status Working with Multiple Areas from a Single KeypadScreen Area Definitions View Point StatusTurning On the System Move To Area CMD + 5 +Turning on Selected Areas Turning on Multiple Areas with a Passcode Faulted Points in Other AreasTurning on All or Selected Areas Turn On the Entire System Without DelaysTurning Off Multiple Areas with a Passcode Turning Off the SystemTurning Off Multiple Areas with Disarm All Turning Off Selected Areas User Authority Levels Supplementary Information for Adding PasscodesPasscode Worksheet User InterfaceAuthority Levels User Passcode Worksheet User 000 to ### User Passcode Worksheet User 039 to Bosch Security Systems, Inc /10 F01U169130-02 User Area Authority ### Passcode Group User Name Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 115 Site Card Data User Area Authority ### Passcode Group Bosch Security Systems, Inc /10 F01U169130-02 Bosch Security Systems, Inc /10 F01U169130-02 Master ID ###-0 Sub-User ###-1 Sub-User ###-2 Sub-User ###-3 User Area Authority ### Passcode Group Bosch Security Systems, Inc /10 F01U169130-02 User Passcode Worksheet Blank User Token Worksheet Blank Security System LimitationsView Fire Safety and EvacuationStandard Displays System Trouble Displays Service D9210 Service PrinterService Zonex Bus 1 or Hour Point BypassSecurity System Glossary How to Clean the Keypad Maintenance and ServiceYour Alarm Company Bosch Security Systems, Inc /10 F01U169130-02 Bosch Security Systems, Inc Perinton Parkway Fairport, NY