Heat & Glo LifeStyle LUX60 owner manual Minimum Clearances for Termination

Page 26

D

E

V

LB

 

 

 

 

 

H

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

N

 

 

C

 

 

 

 

V

 

 

 

 

 

B

V

 

 

 

Fixed

V

 

 

 

V

Openable

Fixed

 

 

 

Closed

 

 

 

 

 

 

 

F V

 

 

 

Closed

 

 

 

 

 

 

 

B

 

 

 

 

 

V

 

 

 

B

 

B

J

X

M

V K X

 

 

 

 

 

 

I

 

 

 

A

GAS METER

 

 

 

 

 

 

 

 

 

 

V TERMINATION CAP

X AIR SUPPLY INLET

RESTRICTION ZONE

 

 

 

 

 

 

(TERMINATION NOT

 

 

 

 

 

 

ALLOWED)

 

G

V

V

A

Measure vertical clearances

 

 

 

 

V

 

 

from this surface

Q

P

 

 

 

 

 

 

 

 

 

 

 

V

 

 

W

 

 

 

 

 

 

 

 

 

 

R

 

V

U

Electrical

U

V

 

T

 

 

Service

 

 

 

 

 

 

 

 

 

S

 

 

D*

 

 

 

 

 

 

 

 

 

 

Covered Alcove

 

 

V

 

 

Measure horizontal clearances

Clearances to Electrical Service

Applications

from this surface.

 

 

 

 

 

 

 

 

 

 

 

 

Dimension Descriptions

AClearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm) minimum. *

BClearance to window or door that may be opened – 10,000 BTUs or less, 6 in. (15 cm) minimum; 10,000-50,000 BTUs, 9 in. (23 cm) minimum; over 50,000 BTUs, 12 in. (30 cm) minimum. *

CClearance to permanently closed window – 12 in. (30 cm) minimum - recommended to prevent condensation on window.

DVertical clearance to ventilated soffit located above the termination within a horizontal distance of 2 ft (60 cm) from the centerline of the termination

– 18 in. (46 cm) minimum. **

EVertical clearance to unventilated soffit - 12 in. (30 cm) minimum. **

FClearance to outside corner - 6 in. (15 cm) minimum.

GClearance to inside corner - 6 in. (15 cm) minimum.

HNot to be installed above a meter/regulator assembly within 3 ft (90 cm) horizontally* from the center line of the regulator (Canada only)

IClearance to service regulator vent outlet – 3 ft (.91 m) U.S. minimum and 3 ft (.91 m) Canada minimum. *

JClearance to non-mechanical air supply inlet into building or the combustion air inlet to any other appliance – 9” (23 cm) U.S. minimum and 12 in. (30 cm) Canada minimum. *

KClearance to mechanical air supply inlet - 3 ft (.91 m) U.S. minimum and 6 ft (1.8 m) Canada minimum. *

LClearance above a paved sidewalk or paved driveway located on public property - 7 ft (2.1 m) minimum.

A vent may not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

MClearance under veranda, porch, deck or balcony - 12 in. (30 cm) minimum. * Recommended 30 in. (76 cm) for vinyl or plastic.

Only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor. *

NVertical clearance between two horizontal termination caps – 12 in. (30 cm) minimum.

OHorizontal clearance between two horizontal termination caps – 12 in. (30 cm) minimum.

Figure 6.3 Minimum Clearances for Termination

P6” - Non-vinyl sidewalls 12” – Vinyl sidewalls

Q18” – Non-vinyl soffit and overhang 42” – Vinyl soffit and overhang

R8 ft.

 

 

S min

T max

1 cap

 

3 ft

2 x S actual

2 caps

 

6 ft

1 x S actual

3 caps

 

9 ft

2/3 x S actual

4 caps

 

12 ft

1/2 x S actual

S min = # term caps x 3

T max = (2/# term caps) x S (actual)

U6” min. – Clearance from sides of electrical service. W 12” min. – Clearance above electrical service.

* As specified in CGA B149 Installation Codes

Note: Local codes or regulations may require different clearances. ** Clearance required to vinyl soffit material – 30 in. (76 cm) minimum.

Note: Location of the vent termination must not interfere with access to the electrical service.

WARNING!

In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must follow all side wall, overhang and ground clearances as stated in the instructions.

Hearth & Home Technologies assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

26

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

Image 26
Contents Installation and Operation ModelsCongratulations Homeowner Reference InformationTable of Contents Reference Materials  B. Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Decorative Doors and Fronts Fixed Glass AssemblyClear Space Operation of the LUX60System Operation Before Lighting FireplaceMatching Security Codes For Your Safety Read Before Lighting IntelliFire Ignition System IPI Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Venting Remote ControlDoors, Surrounds, Fronts Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection Control Compartment and Firebox TopLight Glass Replacement/Cleaning LED Light Bar ReplacementClean Porcelain Panels BackRemove Screws Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Assemble Steel Stud Kit Framing and ClearancesSelect Appliance Location Construct the Appliance Chase ClearancesClearances to Combustibles Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Three ElbowsTwo Elbows Top Vent Vertical TerminationNo Elbow Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and at- ticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceAssemble Vent Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsInstall Metal Roof Flashing Disassemble Vent SectionsAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 16 Venting through the wallField Constructed Shrouds ShroudsHHT Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHWMailbox Style Shroud may be used with DVP-TV, DVP-TVHW Roofed Style Shroud may be used with DVP-TV, DVP-TVHWGas Connection Gas InformationGas Pressure Install Flame Solenoid Setting Flame Height/Manifold PressureElectrical Information Wiring RequirementsElectrical Service and Repair Junction Box Installation Junction Box DetailWall Finishing Standard 1/2 in mm SheetrockAdditional Decorative Finishing up to 1 in mm Thick Additional Decorative Finishing over 1 in mm ThickAir Shutter Access & Adjustment Appliance SetupRemove Glass Assembly Clean the ApplianceOutside Burner Tube Air Shutter Adjustment Center Burner Tube Air ShutterInstall Glass Rock Install Glass RockTroubleshooting IntelliFire IPI Ignition SystemIntelliFire IPI Ignition System Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Optional Components Contact Information Do not Discard this Manual