LIMITED LIFETIME WARRANTY

Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.

WARRANTY COVERAGE:

HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo- nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.

WARRANTY PERIOD:

Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table.

The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.

Warranty Period

 

HHT Manufactured Appliances and Venting

Parts

Labor

Gas

Wood

Pellet

EPA

Coal

Electric

Venting

Wood

 

 

 

 

 

 

 

 

Components Covered

1 Year

X

X

X

X

X

 

 

 

 

 

X

X

All parts and material except as

covered by Conditions,

Exclusions, and Limitations

listed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

 

 

 

Igniters, electronic components,

 

 

 

2 years

 

 

 

 

 

and glass

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

X

X

 

 

 

Factory-installed blowers

 

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

Molded refractory panels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 years

 

 

X

 

 

 

 

 

Firepots and burnpots

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 years

1 year

 

 

X

X

 

 

 

 

Castings and baffles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 years

3 years

 

X

X

X

 

 

 

 

Manifold tubes,

 

 

 

 

 

 

 

HHT chimney and termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

1 year

X

 

 

 

 

 

 

 

Burners, logs and refractory

 

 

years

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limited

3 years

X

X

X

X

X

 

 

 

Firebox and heat exchanger

 

 

Lifetime

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 Days

X

X

X

X

X

X

 

X

All replacement parts

 

 

 

beyond warranty period

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See conditions, exclusions, and limitations on next page.

4021-645C 12-29-10

 

 

 

 

 

 

 

 

Page 1 of 2

 

 

 

 

 

 

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

 

5

Image 5
Contents Models Installation and OperationHomeowner Reference Information CongratulationsTable of Contents Reference Materials Limited Lifetime Warranty  B. Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Clear Space Fixed Glass AssemblyDecorative Doors and Fronts Operation of the LUX60System Operation Before Lighting FireplaceMatching Security Codes IntelliFire Ignition System IPI Lighting Instructions For Your Safety Read Before LightingAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Venting Remote ControlDoors, Surrounds, Fronts Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianFirebox Control Compartment and Firebox TopLED Light Bar Replacement Light Glass Replacement/CleaningBack Clean Porcelain PanelsRemove Screws Typical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Assemble Steel Stud Kit Framing and ClearancesSelect Appliance Location Clearances Construct the Appliance ChaseClearances to Combustibles Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Approved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Three Elbows Two 45 Elbows replacing One 90 ElbowTwo Elbows Top Vent Vertical TerminationNo Elbow Pipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationCeiling firestop Must be used between floors and at- tics Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Secure and Level the Appliance Appliance PreparationAttach Pipe to the Firebox Assembly Install Vent PipeAssemble Vent Sections Assemble Pipe SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Metal Roof Flashing13 Assembling the Storm Collar Assemble and Install Storm CollarHeat Shield Requirements for Horizontal Termination Install Vertical Termination Cap16 Venting through the wall Install Horizontal Termination CapHHT Shrouds ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHWRoofed Style Shroud may be used with DVP-TV, DVP-TVHW Mailbox Style Shroud may be used with DVP-TV, DVP-TVHWGas Connection Gas InformationGas Pressure Setting Flame Height/Manifold Pressure Install Flame SolenoidElectrical Information Wiring RequirementsElectrical Service and Repair Junction Box Detail Junction Box InstallationStandard 1/2 in mm Sheetrock Wall FinishingAdditional Decorative Finishing over 1 in mm Thick Additional Decorative Finishing up to 1 in mm ThickRemove Glass Assembly Appliance SetupAir Shutter Access & Adjustment Clean the ApplianceCenter Burner Tube Air Shutter Outside Burner Tube Air Shutter AdjustmentInstall Glass Rock Install Glass RockIntelliFire IPI Ignition System TroubleshootingIntelliFire IPI Ignition System Reference Materials Appliance Dimension DiagramDVP45 Vent Components DiagramsDVP-TRAPFL DVP-TVHW DVP-TRAP Optional Components Do not Discard this Manual Contact Information