Heat & Glo LifeStyle LUX60 Install Flame Solenoid, Setting Flame Height/Manifold Pressure

Page 44

Note: The flame solenoid is assembled and preset from the factory. Should it become necessary to reinstall the flame solenoid, refer to the follwing sections (12.D & 12.E) for proper reinstallation.

D. Install Flame Solenoid

Remove the screw and knob from the variable regulator and discard.

Remove the nut from the regulator and discard.

Remove the bag containing a washer and blue and red plungers from the side of the flame control solenoid.

Place washer on flame control solenoid.

Insert the correct plunger (blue - natural gas, red - propane) into the flame control solenoid.

Thread the flame control solenoid with correct plunger into the threaded hole in the variable regulator. Turn into valve approximately two full turns. Do not tighten or damage may occur.

Connect orange wires from control box to the flame control solenoid.

E. Setting Flame Height/Manifold Pressure

(To be done by a qualified service technician.) Upon initial power-up of this device, valve pressure must be set for flame adjustment.

Loosen output pressure tap on valve and connect with pressure manometer.

Press flame button once; fireplace will light with flames on high.

Turn solenoid clockwise to increase pressure, counterclockwise to decrease pressure until manifold pressure on high is 3.5 in. water column for natural gas (NG), 10.0 in. water column for propane (LP).

Once pressure is achieved spin jam nut on solenoid tight against regulator face to prevent rotation. Do not overtighten.

Press flame button twice to turn fireplace off.

Remove manometer tube and tighten or close pressure tap. Use a commercially available, noncorrosive leak check solution to carefully check the pressure tap for leaks. Be sure to rinse off all leak check solution following testing.

Gas Control

 

Valve

Knob

 

Screw

Washer

Nut

 

Variable

Regulator Washer

Variable

 

 

 

Regulator

 

 

Solenoid

 

 

 

Flame Control

Variable

Plunger

Jam Nut

Solenoid

Regulator

 

 

 

Figure 12.1 Install the Flame Solenoid

44

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

Image 44
Contents Installation and Operation ModelsCongratulations Homeowner Reference InformationTable of Contents Reference Materials  B. Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Clear SpaceDecorative Doors and Fronts Operation of the LUX60System Operation Before Lighting FireplaceMatching Security Codes For Your Safety Read Before Lighting IntelliFire Ignition System IPI Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Venting Remote ControlDoors, Surrounds, Fronts Maintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionFirebox Control Compartment and Firebox TopLight Glass Replacement/Cleaning LED Light Bar ReplacementClean Porcelain Panels BackRemove Screws Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Assemble Steel Stud Kit Framing and ClearancesSelect Appliance Location Construct the Appliance Chase ClearancesClearances to Combustibles Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Three ElbowsTwo Elbows Top Vent Vertical TerminationNo Elbow Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and at- ticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsInstall Metal Roof Flashing Disassemble Vent SectionsAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 16 Venting through the wallShrouds HHT ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHWMailbox Style Shroud may be used with DVP-TV, DVP-TVHW Roofed Style Shroud may be used with DVP-TV, DVP-TVHWGas Connection Gas InformationGas Pressure Install Flame Solenoid Setting Flame Height/Manifold PressureElectrical Information Wiring RequirementsElectrical Service and Repair Junction Box Installation Junction Box DetailWall Finishing Standard 1/2 in mm SheetrockAdditional Decorative Finishing up to 1 in mm Thick Additional Decorative Finishing over 1 in mm ThickAppliance Setup Remove Glass AssemblyAir Shutter Access & Adjustment Clean the ApplianceOutside Burner Tube Air Shutter Adjustment Center Burner Tube Air ShutterInstall Glass Rock Install Glass RockTroubleshooting IntelliFire IPI Ignition SystemIntelliFire IPI Ignition System Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Optional Components Contact Information Do not Discard this Manual