Heat & Glo LifeStyle LUX60 owner manual Dvp-Trapfl

Page 56

B. Vent Components Diagrams (continued)

 

 

 

 

31 in.

 

 

 

 

(787 mm)

13-1/4 in.

 

 

24-5/8 in.

 

 

 

 

(625 mm)

 

 

(367 mm)

 

 

 

 

 

 

 

 

 

24-5/8 in.

27-1/2 in.

 

 

13-1/4 in.

(625 mm)

(698 mm)

 

 

 

 

(367 mm)

 

 

 

 

 

RF6M

 

 

 

RF12M

 

Roof Flashing Multi-pak

 

Roof Flashing Multi-pak

13-3/4 in.

 

5 in.

 

11-7/8 in.

5 in.

(349 mm)

 

(127 mm)

 

(302 mm)

(127 mm)

13-3/4 in.

 

 

13-7/8 in.

 

 

(349 mm)

 

 

(352 mm)

 

 

BEK

 

 

 

DVP-BEK2

Trap Cap Brick Extension

 

DVP-HPC Cap Brick Extension

 

 

 

11-5/8 in.

 

 

 

 

 

(295 mm)

 

 

 

 

 

7-1/8 in.

12-1/8 in.

 

 

 

(308 mm)

 

 

 

(181 mm)

 

 

 

 

 

 

 

 

5-3/4 in.

 

 

 

 

 

(146 mm)

 

 

 

 

 

 

COOL-ADD

DVP-TRAPFL

 

 

 

Cap Shield

 

 

 

 

 

Flashing

 

 

 

 

 

 

 

 

13-7/8 in.

9-1/2 in.

26 in.

 

 

(352 mm)

(241 mm)

 

 

 

 

 

(660 mm)

 

 

 

 

 

 

 

 

14 in.

 

 

 

 

 

(356 mm)

 

 

DVP-HSM-B

 

 

 

DRC-RADIUS

Extended Heat Shield

 

 

 

 

 

 

Cap Shield

 

 

 

 

Figure 17.3 DVP Vent Components

 

 

 

 

 

56

 

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

 

 

Image 56
Contents Installation and Operation ModelsCongratulations Homeowner Reference InformationTable of Contents Reference Materials  B. Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Fixed Glass Assembly Clear SpaceDecorative Doors and Fronts Operation of the LUX60System Operation Before Lighting FireplaceMatching Security Codes For Your Safety Read Before Lighting IntelliFire Ignition System IPI Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Venting Remote ControlDoors, Surrounds, Fronts Maintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionFirebox Control Compartment and Firebox TopLight Glass Replacement/Cleaning LED Light Bar ReplacementClean Porcelain Panels BackRemove Screws Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Assemble Steel Stud Kit Framing and ClearancesSelect Appliance Location Construct the Appliance Chase ClearancesClearances to Combustibles Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Three ElbowsTwo Elbows Top Vent Vertical TerminationNo Elbow Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and at- ticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsInstall Metal Roof Flashing Disassemble Vent SectionsAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 16 Venting through the wallShrouds HHT ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHWMailbox Style Shroud may be used with DVP-TV, DVP-TVHW Roofed Style Shroud may be used with DVP-TV, DVP-TVHWGas Connection Gas InformationGas Pressure Install Flame Solenoid Setting Flame Height/Manifold PressureElectrical Information Wiring RequirementsElectrical Service and Repair Junction Box Installation Junction Box DetailWall Finishing Standard 1/2 in mm SheetrockAdditional Decorative Finishing up to 1 in mm Thick Additional Decorative Finishing over 1 in mm ThickAppliance Setup Remove Glass AssemblyAir Shutter Access & Adjustment Clean the ApplianceOutside Burner Tube Air Shutter Adjustment Center Burner Tube Air ShutterInstall Glass Rock Install Glass RockTroubleshooting IntelliFire IPI Ignition SystemIntelliFire IPI Ignition System Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Optional Components Contact Information Do not Discard this Manual