Heat & Glo LifeStyle LUX60 owner manual Center Burner Tube Air Shutter

Page 50

-Remove three cover plates by removing two screws from each plate. See Figure 15.3.

Remove

Plates

Figure 15.3 Remove Three Plates

-Remove three outside burner tubes by removing two screws on each tube. See Figure 15.4.

Figure 15.4 Remove Outside Burner Tubes

-Outside burner tube air shutters may be adjusted as shown in Figure 15.5.

Figure 15.5 Outside Burner Tube Air Shutter Adjustment

Center Burner Tube Air Shutter

-Remove decorative steel log assembly by removing 3 screws, lifting up and out (Figure 15.6).

Figure 15.6 Remove Decorative Steel Log Assembly

-Center burner tube air shutter is now accessible with short phillips screw driver (see Figure 15.7).

Figure 15.7 Adjust Center Burner Tube Air Shutter

-Loosen phillips screw and turn air shutter for optimum flame appearance.

50

Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11

Image 50
Contents Installation and Operation ModelsCongratulations Homeowner Reference InformationTable of Contents Reference Materials  B. Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions Decorative Doors and Fronts Fixed Glass AssemblyClear Space Operation of the LUX60System Operation Before Lighting FireplaceMatching Security Codes For Your Safety Read Before Lighting IntelliFire Ignition System IPI Lighting InstructionsAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Venting Remote ControlDoors, Surrounds, Fronts Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection Control Compartment and Firebox TopLight Glass Replacement/Cleaning LED Light Bar ReplacementClean Porcelain Panels BackRemove Screws Getting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Assemble Steel Stud Kit Framing and ClearancesSelect Appliance Location Construct the Appliance Chase ClearancesClearances to Combustibles Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsOne Elbow Vent DiagramsTop Vent Horizontal Termination Two 45 Elbows replacing One 90 Elbow Three ElbowsTwo Elbows Top Vent Vertical TerminationNo Elbow Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and at- ticsVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Secure and Level the ApplianceAssemble Vent Sections Install Vent PipeAttach Pipe to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsInstall Metal Roof Flashing Disassemble Vent SectionsAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap 16 Venting through the wallField Constructed Shrouds ShroudsHHT Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHWMailbox Style Shroud may be used with DVP-TV, DVP-TVHW Roofed Style Shroud may be used with DVP-TV, DVP-TVHWGas Connection Gas InformationGas Pressure Install Flame Solenoid Setting Flame Height/Manifold PressureElectrical Information Wiring RequirementsElectrical Service and Repair Junction Box Installation Junction Box DetailWall Finishing Standard 1/2 in mm SheetrockAdditional Decorative Finishing up to 1 in mm Thick Additional Decorative Finishing over 1 in mm ThickAir Shutter Access & Adjustment Appliance SetupRemove Glass Assembly Clean the ApplianceOutside Burner Tube Air Shutter Adjustment Center Burner Tube Air ShutterInstall Glass Rock Install Glass RockTroubleshooting IntelliFire IPI Ignition SystemIntelliFire IPI Ignition System Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP Optional Components Contact Information Do not Discard this Manual