Regency P42-NG3, P42-LP3 installation manual For All Horizontal Terminations

Page 14

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS

REGENCY DIRECT VENT SYSTEM (FLEX) - Propane & Natural Gas

The diagram below shows examples of horizontal termination arrangements using two 90o elbows.

Note:

1)

A maximum of two 90o elbows are permitted (two 45o elbows equal one 90o elbow).

 

2)

A minimum of 6 ft.(1.8m) vertical from base of unit is required if two 90o elbows are used.

 

3)

Minimum distance between elbows is 2 ft. (0.6m).

If length "B" is increased, length "A" must be decreased by a corresponding amount.

For All Horizontal Terminations

All Rigid Pipe Systems 4" inner diameter

6-5/8" outer diameter

Regency Flex Vent 4" inner diameter

6-7/8" outer diameter

A vent guard may be required, check local codes.

Maintain a 1-1/4" clearance to

combustibles for rigid pipe systems and 1-1/2" for Regency Flex Vent.

• Horizontalventmustbesupportedevery 3 feet

Firestops are required at each floor

level and whenever passing through a wall.

Note: Regency Direct Vent System (Flex) is only approved for horizontal termina- tions.

14

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

Image 14
Contents P42 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P42Installation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat ReleaseClearances Mantels Mantel LEG ClearancesVenting Introduction TOP Assembly Nailing StripsFraming Finishing Vent RestrictorExterior Vent Termination Venting Regency Direct Vent System Flex Horizontal Terminations OnlyRigid Pipe Venting Components List 4DT-AJBHorizontal Rigid Pipe VentingAlternate TerminationRigid Pipe Venting Arrangements Horizontal Terminations Vent guard may be required, check local codesFor All Horizontal Terminations Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasVent restrictor #6 must be used Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsInstallation Snorkel Terminations Horizontal InstallationsBelow Grade Installation Vertical Termination Continue to assemble pipe lengthsFor Regency Direct Vent System Flex Installation ProceduresOffset Chart High Elevation GAS Line InstallationGAS Pipe Pressure Testing Aeration Brick Panels Adjustment Propane LOG SET InstallationNatural GAS Burner tray without front logs in placeDouble Screen Door Standard Flush DoorFlush Louvers Not under the gas lineOptional Bay Trim Optional BAY DoorBAY Louvers Full Screen Door Frame Installation Full Screen FrontHinge Location Bottom Grill Hinge Screen Door Do not cut the ground terminal off under any circumstances Wiring DiagramTo Thermocouple T Valve Lighting Procedure Remote ControlOptional Wall Switch Operating InstructionsCopy of the Lighting Plate Instructions Temperatures keep children, clothingClean. See installation Shutdown Procedure MaintenanceMaintenance First FireGOLD-PLATED Louvers Glass ReplacementLOG Replacement Thermopile ThermocoupleShut the power off Removing the FAN Replacing the FANInstalling Valve Parts List P42 Main AssemblyP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information