Regency P42-LP3, P42-NG3 Save These Instructions, Before YOU Start, Installation Checklist

Page 5

INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The P42-NG/P42-LP Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULDBEDONEBYANAUTHOR- IZED SERVICE PERSON. THE AP- PLIANCESHOULDBEINSPECTED BEFORE USE AND AT LEAST AN- NUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FRE- QUENT CLEANING MAY BE RE- QUIRED DUE TO EXCESSIVE LINT FROMCARPETING,BEDDINGMA- TERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPART- MENTS,BURNERSANDCIRCULAT- ING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LO- CATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERA- TURES, ESPECIALLY THE FIRE- PLACE GLASS, AND SHOULD STAYAWAYTOAVOIDBURNSOR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEYAREINTHESAMEROOMAS THE APPLIANCE.

CLOTHING OR OTHER FLAMMA- BLE MATERIAL SHOULD NOT BE PLACEDONORNEARTHEAPPLI- ANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes, with the current Canadian or Nation- al Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be elec- trically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/ NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specified vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fitted as per Venting instructions.

5)Inspect the venting system annually for blockage and any signs of deterioration.

6)Venting terminals shall not be recessed into a wall or siding.

7)Any safety glass removed for servicing must be replaced prior to operating the appliance.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Wear gloves and safety glasses for pro- tection while doing required maintenance.

10)Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination.

11)Under no circumstances should this appli- ance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

12)Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance

annually. Make it a practice to have all of your gas appliances checked annually.

13)Do not slam shut or strike the glass door.

14)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

15)The appliance area must be kept clear and free of combustible materials, (gases and other flammable vapours and liquids).

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSTALLATION

CHECKLIST

1)Locate appliance

a)Room location, page 6

b)Clearances to Combustibles, page 7

c)Mantle Clearances, page 7

d)Framing & Finishing Requirements, page 8

e)Venting Requirements, pages 8-18.

2)Assemble Top Facing Support and Side Nailing Strips, page 8. NOTE: must be done before installing unit into fire- place.

3)Install venting, pages 19-21.

4)Make gas and electrical connections. Test the pilot. Must be as per diagram. Page 22.

5)Test Gas Pressure. Page 22.

6)Install brick panels (optional), page 23.

7)Install Flush Door Front (Standard) and optional Flush Gold Trim, page 25. Install Optional Door Screen, page 25.

8)Install Optional Bay Front and optional Bay Gold Trim, page 26.

9)Install Louvers (Flush or Bay), pages 25- 26.

10)Install optional Wall Switch, Remote Con- trol, or Wall Thermostat, page 31.

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

5

Image 5
Contents P42 Gas Fireplace To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelGeneral Safety Information InstallationInstallation Checklist Save These InstructionsManufactured Mobile Home Additional Requirements Unit Specifications Locating Your GAS StoveOptional Duct System Optional Heat ReleaseMantel LEG Clearances Clearances MantelsFraming Finishing TOP Assembly Nailing StripsVenting Introduction Vent RestrictorExterior Vent Termination Regency Direct Vent System Flex Horizontal Terminations Only Venting4DT-AJB Rigid Pipe Venting Components ListAlternate Rigid Pipe VentingHorizontal TerminationVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal TerminationsFor All Horizontal Terminations Propane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsInstallation Snorkel Terminations Horizontal InstallationsBelow Grade Installation Continue to assemble pipe lengths Vertical TerminationFor Regency Direct Vent System Flex Installation ProceduresOffset Chart High Elevation GAS Line InstallationGAS Pipe Pressure Testing Aeration Brick Panels Adjustment Natural GAS LOG SET InstallationPropane Burner tray without front logs in placeFlush Louvers Standard Flush DoorDouble Screen Door Not under the gas lineOptional Bay Trim Optional BAY DoorBAY Louvers Full Screen Front Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door Do not cut the ground terminal off under any circumstances Wiring DiagramTo Thermocouple T Valve Optional Wall Switch Remote ControlLighting Procedure Operating InstructionsCopy of the Lighting Plate Instructions Temperatures keep children, clothingClean. See installation Maintenance MaintenanceShutdown Procedure First FireLOG Replacement Glass ReplacementGOLD-PLATED Louvers Thermopile ThermocoupleRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information