Regency P42-LP3 Standard Flush Door, Flush Louvers, Double Screen Door, Not under the gas line

Page 25

INSTALLATION

STANDARD

FLUSH DOOR

The standard flush door comes with a black frame. To install the frame, simply hook the top door flange onto the top of the unit and swing the door towards the unit, diagram 1.

FLUSH LOUVERS

1)Install the top louver by sliding the two bracket clips into the brackets located un- derneath the top of the firebox. Diagram 1.

2)Attach the 2 bottom louver hinges to the bottom flange on the firebox using 2 screws per hinge. Diagram 1.

DOUBLE SCREEN

DOOR

1)Pull out the top louver.

2)Center the screen door and hook over the flush door.

Diagram 1

Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. Diagram 2.

Diagram 2

Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd and 3rd spring. See diagram 3.

Diagram 3

NOTE: Springs must always be OVER

not under the gas line.

To remove the flush door, reverse the above steps.

Diagram 1

Note: Top and bottom louvers are different.

3)Attach the bottom louver to the 2 hinges using 2 screws per hinge. Diagram 2.

Diagram 2

3)Open the screen door(s) and secure the screen door to the flush door front with 2 clips on the bottom left and right side.

Clip locations

Clip installed on right side.

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

25

Image 25
Contents P42 Gas Fireplace To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelGeneral Safety Information InstallationInstallation Checklist Save These InstructionsManufactured Mobile Home Additional Requirements Unit Specifications Locating Your GAS StoveOptional Duct System Optional Heat ReleaseMantel LEG Clearances Clearances MantelsFraming Finishing TOP Assembly Nailing StripsVenting Introduction Vent RestrictorExterior Vent Termination Regency Direct Vent System Flex Horizontal Terminations Only Venting4DT-AJB Rigid Pipe Venting Components ListAlternate Rigid Pipe VentingHorizontal TerminationVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal TerminationsFor All Horizontal Terminations Propane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Required Parts Vertical Termination With CO-LINEAR Flex SystemDescription Alternate Approved CapsInstallation Below Grade Installation Horizontal InstallationsSnorkel Terminations Continue to assemble pipe lengths Vertical TerminationOffset Chart Installation ProceduresFor Regency Direct Vent System Flex GAS Pipe Pressure Testing GAS Line InstallationHigh Elevation Aeration Brick Panels Adjustment Natural GAS LOG SET InstallationPropane Burner tray without front logs in placeFlush Louvers Standard Flush DoorDouble Screen Door Not under the gas lineBAY Louvers Optional BAY DoorOptional Bay Trim Full Screen Front Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door To Thermocouple T Valve Wiring DiagramDo not cut the ground terminal off under any circumstances Optional Wall Switch Remote ControlLighting Procedure Operating InstructionsClean. See installation Temperatures keep children, clothingCopy of the Lighting Plate Instructions Maintenance MaintenanceShutdown Procedure First FireLOG Replacement Glass ReplacementGOLD-PLATED Louvers Thermopile ThermocoupleRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information