Regency P42-LP3, P42-NG3 Operating Instructions, Remote Control, Optional Wall Switch

Page 31

OPERATING INSTRUCTIONS

OPTIONAL

OPTIONAL

OPERATING

REMOTE CONTROL

WALL THERMOSTAT

INSTRUCTIONS

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location. Use Thermostat Wire Table.

2)Connect the two wires to the gas valve. See diagram below.

CAUTION

Do not wire millivolt remote control wires to 120V wire.

3)Install 3 AAA alkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

OPTIONAL

WALL SWITCH

1)Run the supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire.

Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wire Table.

2)Connect the wire to the supplied wall switch and install into the receptacle box.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use table below to determine the maximum wire length.

Note: Preferable if the thermostat is in- stalled on an interior wall.

Regency offers an optional programmable ther- mostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not wire millivolt wall thermostat wires to 120V wire.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

14 GA.

50 Ft.

 

16 GA.

32 Ft.

 

18 GA.

20 Ft.

 

20 GA.

12 Ft.

 

22 GA.

9 Ft.

 

 

 

 

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the ap- pliance with the glass removed or with broken glass.

5)Verify that the venting and cap are unob- structed.

6)Ensure that the brick panels are installed.

7)Verify log placement. If the pilot cannot be seen when lighting the unit, the logs have been incorrectly positioned.

8)The unit should never be turned off, and on again without a minimum of a 60 second wait.

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot,

you must first release the

tension springs below the door.

Only when the pilot holds, without pressure being applied to the control knob, reapply the tension springs to the door. The unit must not be operated with the tension springs unattached.

IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Turn burner OFF using "ON/OFF" switch.

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

31

Image 31
Contents P42 Gas Fireplace To the New Owner Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Copy of Safety Decal for P42 Safety LabelSave These Instructions InstallationGeneral Safety Information Installation ChecklistOptional Heat Release Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Duct SystemMantel LEG Clearances Clearances MantelsVent Restrictor TOP Assembly Nailing StripsFraming Finishing Venting IntroductionExterior Vent Termination Regency Direct Vent System Flex Horizontal Terminations Only Venting4DT-AJB Rigid Pipe Venting Components ListTermination Rigid Pipe VentingAlternate HorizontalVent guard may be required, check local codes Rigid Pipe Venting Arrangements Horizontal TerminationsFor All Horizontal Terminations Propane & Natural Gas Rigid Pipe Venting Arrangements Vertical TerminationsVent restrictor #6 must be used Alternate Approved Caps Vertical Termination With CO-LINEAR Flex SystemRequired Parts DescriptionInstallation Below Grade Installation Horizontal InstallationsSnorkel Terminations Continue to assemble pipe lengths Vertical TerminationOffset Chart Installation ProceduresFor Regency Direct Vent System Flex GAS Pipe Pressure Testing GAS Line InstallationHigh Elevation Aeration Brick Panels Adjustment Burner tray without front logs in place LOG SET InstallationNatural GAS PropaneNot under the gas line Standard Flush DoorFlush Louvers Double Screen DoorBAY Louvers Optional BAY DoorOptional Bay Trim Full Screen Front Full Screen Door Frame InstallationHinge Location Bottom Grill Hinge Screen Door To Thermocouple T Valve Wiring DiagramDo not cut the ground terminal off under any circumstances Operating Instructions Remote ControlOptional Wall Switch Lighting ProcedureClean. See installation Temperatures keep children, clothingCopy of the Lighting Plate Instructions First Fire MaintenanceMaintenance Shutdown ProcedureThermopile Thermocouple Glass ReplacementLOG Replacement GOLD-PLATED LouversRemoving the FAN Replacing the FAN Shut the power offInstalling Valve P42 Main Assembly Parts ListP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information