Regency P42-NG3, P42-LP3 installation manual Installing Valve

Page 36

MAINTENANCE

INSTALLING VALVE

1)Attach the valve bracket to the valve with the 4 (m5x8 metric) screws provided.

2)Reconnect the "gas out" 90o elbow flare fitting with an 11/16" wrench.

3)Reconnect the "gas out" flare nut with a 13/16" wrench.

4)Reconnect the quick drop out thermocouple nut with a 9mm wrench.

5)Reconnect the pilot tube nut with a 7/16" wrench.

6)Scrape off the old gasket from the floor of the firebox.

7)Install a new gasket and reinstall the valve assembly.

Note: Failure to install a new gasket may severely affect the appliance per- formance.

8)Reinstall the 12 hold down screws.

9)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.

10)Reinstall the burner grate. Put a dab of high temperature silicone over the 3 screw holes.

11)Install Burner tube.

12)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open flame for leak testing.)

13)Fire up the unit.

14)Check the manifold pressure.

15)Reinstall the vermiculite, embers, rock- wool and logs as needed.

16)Install and close the door and replace the louvers.

36

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

Image 36
Contents P42 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P42Installation General Safety InformationInstallation Checklist Save These InstructionsUnit Specifications Locating Your GAS Stove Manufactured Mobile Home Additional RequirementsOptional Duct System Optional Heat ReleaseClearances Mantels Mantel LEG ClearancesTOP Assembly Nailing Strips Framing FinishingVenting Introduction Vent RestrictorExterior Vent Termination Venting Regency Direct Vent System Flex Horizontal Terminations OnlyRigid Pipe Venting Components List 4DT-AJBRigid Pipe Venting AlternateHorizontal TerminationRigid Pipe Venting Arrangements Horizontal Terminations Vent guard may be required, check local codesFor All Horizontal Terminations Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasVent restrictor #6 must be used Vertical Termination With CO-LINEAR Flex System Required PartsDescription Alternate Approved CapsInstallation Horizontal Installations Below Grade InstallationSnorkel Terminations Vertical Termination Continue to assemble pipe lengthsInstallation Procedures Offset ChartFor Regency Direct Vent System Flex GAS Line Installation GAS Pipe Pressure TestingHigh Elevation Aeration Brick Panels Adjustment LOG SET Installation Natural GASPropane Burner tray without front logs in placeStandard Flush Door Flush LouversDouble Screen Door Not under the gas lineOptional BAY Door BAY LouversOptional Bay Trim Full Screen Door Frame Installation Full Screen FrontHinge Location Bottom Grill Hinge Screen Door Wiring Diagram To Thermocouple T ValveDo not cut the ground terminal off under any circumstances Remote Control Optional Wall SwitchLighting Procedure Operating InstructionsTemperatures keep children, clothing Clean. See installationCopy of the Lighting Plate Instructions Maintenance MaintenanceShutdown Procedure First FireGlass Replacement LOG ReplacementGOLD-PLATED Louvers Thermopile ThermocoupleShut the power off Removing the FAN Replacing the FANInstalling Valve Parts List P42 Main AssemblyP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information