Regency P42-NG3, P42-LP3 Venting, Regency Direct Vent System Flex Horizontal Terminations Only

Page 10

INSTALLATION

VENTING

Regency Direct Vent System (Flex) Horizontal Terminations Only

These venting systems, in combination with the P42 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. The location of the termi- nation cap must conform to the requirements in the Vent Terminal Locations diagram on page 9.

Regency Direct Vent (Flex) System Ter- mination Kit (Part # 946-515) includes all the parts needed to install the P42 with a maximum run of 4 feet.

1)6-7/8" dia. flexible liner (4 ft. length)

2)4" dia. flexible liner (4 ft. length)

3)spring spacers (4)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1/2" Drill Point, stainless steel

(4)

If longer runs are needed, the Regency Direct Vent system (Flex) # 946-516 in- cludes all the parts needed to install the P42 with a maximum 10' run.

1)6-7/8" dia. flexible liner (10 ft. length)

2)4" dia. flexible liner (10 ft. length)

3)spring spacers (7)

4)thimble (2)

5)AstroCap termination cap (1)

6)screws (12)

7)tube of Mill Pac (1)

8)plated screws (8)

9)screws #8 x 1/2" Drill Point, stainless steel

(4)

Note:

a)Liner sections should be continuous with- out any joints or seams.

b)Only Flex pipe purchased from Regency may be used for Flex Installations.

10

Regency P42-3 Zero Clearance Direct Vent Gas Fireplace

Image 10
Contents P42 Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale To the New OwnerTable of Contents Safety Label Copy of Safety Decal for P42Installation Checklist InstallationGeneral Safety Information Save These InstructionsOptional Duct System Unit Specifications Locating Your GAS StoveManufactured Mobile Home Additional Requirements Optional Heat ReleaseClearances Mantels Mantel LEG ClearancesVenting Introduction TOP Assembly Nailing StripsFraming Finishing Vent RestrictorExterior Vent Termination Venting Regency Direct Vent System Flex Horizontal Terminations OnlyRigid Pipe Venting Components List 4DT-AJBHorizontal Rigid Pipe VentingAlternate TerminationRigid Pipe Venting Arrangements Horizontal Terminations Vent guard may be required, check local codesFor All Horizontal Terminations Rigid Pipe Venting Arrangements Vertical Terminations Propane & Natural GasVent restrictor #6 must be used Description Vertical Termination With CO-LINEAR Flex SystemRequired Parts Alternate Approved CapsInstallation Below Grade Installation Horizontal InstallationsSnorkel Terminations Vertical Termination Continue to assemble pipe lengthsOffset Chart Installation ProceduresFor Regency Direct Vent System Flex GAS Pipe Pressure Testing GAS Line InstallationHigh Elevation Aeration Brick Panels Adjustment Propane LOG SET InstallationNatural GAS Burner tray without front logs in placeDouble Screen Door Standard Flush DoorFlush Louvers Not under the gas lineBAY Louvers Optional BAY DoorOptional Bay Trim Full Screen Door Frame Installation Full Screen FrontHinge Location Bottom Grill Hinge Screen Door To Thermocouple T Valve Wiring DiagramDo not cut the ground terminal off under any circumstances Lighting Procedure Remote ControlOptional Wall Switch Operating InstructionsClean. See installation Temperatures keep children, clothingCopy of the Lighting Plate Instructions Shutdown Procedure MaintenanceMaintenance First FireGOLD-PLATED Louvers Glass ReplacementLOG Replacement Thermopile ThermocoupleShut the power off Removing the FAN Replacing the FANInstalling Valve Parts List P42 Main AssemblyP42 Burner & LOG Assembly P42 Flush Door & Louvers P42 BAY Front & Louvers Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Regency P42-3 Zero Clearance Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information