Burnham ES2 manual Burner Orifices LP Gas 1.20mm

Page 23

Repair Parts LIST (continued)

Key

No.

3A

3B

3C

3D

3E

3F

3G

Description

 

 

[Quantity] Part Number

 

 

ES23

ES24

ES25

ES26

ES27

ES28

ES29

 

Gas Valve (Natural Gas),

 

81660282

 

 

N/A

 

Honeywell VR8204P1171

 

 

 

 

 

 

 

 

 

 

 

Gas Valve (Natural Gas),

 

N/A

 

 

81660283

 

Honeywell VR8304P4496

 

 

 

 

 

 

 

 

 

 

 

Gas Valve (LP Gas), Honeywell

 

81660146

 

 

N/A

 

VR8204C3015

 

 

 

 

 

 

 

 

 

 

 

Gas Valve (LP Gas), Honeywell

 

N/A

 

 

81660160

 

VR8304P4314

 

 

 

 

 

 

 

 

 

 

 

½" Gas Manifold

82207031

82207041

82207051

82207061

 

N/A

 

¾" Gas Manifold

 

N/A

 

82207071

82207081

82207091

Burner Orifices - Natural Gas #47

[4]

[6]

[8]

[10]

[12]

[14]

[16]

822710

822710

822710

822710

822710

822710

822710

 

Burner Orifices - LP Gas 1.20mm

[4]

[6]

[8]

[10]

[12]

[14]

[16]

822792

822792

822792

822792

822792

822792

822792

 

Pilot Burner

 

 

 

100147-01

 

 

 

Pilot Assembly - Natural Gas

 

 

 

102592-01

 

 

 

Pilot Assembly - LP Gas

 

 

 

102593-01

 

 

 

Main Burner

[3]

[5]

[7]

[9]

[11]

[13]

[15]

100146-01

100146-01

100146-01

100146-01

100146-01

100146-01

100146-01

 

Pilot Tubing

 

 

 

8236122

 

 

 

23

Image 23
Contents ES2 Page Whats in the crate? ES2 Series SpecificationsSpecifications Appendices InstallationBoiler Quick-Start Position the Boiler Unpack the CrateConnect Venting Provide Combustion AirConnect Venting ES2 Vent Connector Horizontal Length Restrictions ftConnect Boiler Water Piping Connect Gas PipingDescription Burnham Part Number Connect Boiler Water Piping Connect Electrical WiringStatus Code Displayed in STA Mode Using IQ Boiler Control DisplayViewing the Operating Mode Options Operating Mode OptionsAdjustment Mode Options Changing the Adjustable ParametersMore Information about Adjustable Parameters Using the IQ Option PanelCheck for Gas and Water Leaks Using the Optional LCD Display KitBoiler restarts Perform Startup Checks and AdjustmentsAnnual Maintenance Checklist IQ Boiler Control Status Codes when Err is not displayed TroubleshootingIQ Boiler Control Error Codes when Err is flashing TroubleshootingDisplay Status Boiler / Control Actions IQ Option Panel Display Shows ERRRepair Parts List Repair Parts List Burner Orifices LP Gas 1.20mm IQ Boiler Control Jacket Vestibule Panel Supply Water Manifold Figure IW-1 Wiring Diagram Internal WiringFigure IW-2 Wiring Schematic Internal WiringFigure IW-3 Single Zone System with Domestic Hot Water Tank Figure IW-5 Multiple Zone System with Zone Valves Figure IW-7 Multiple Zone System with Zone Valve Panel Combined appliance Input BTU/hr Appendix a Combustion AirAppendix B Venting Figure B-1 Typical Atmospheric Vent Installation This page Intentionally Left Blank Length W.c. Pressure Drop Feet Appendix C Gas PipingAppendix D System Piping Appendix C Gas PipingHot Water Boilers, Non-Condensing Appendix D System PipingFigure D-0 Piping Schematic Symbols Figure D-W1 Water Boiler, Series Loop Figure D-W3 Water Boiler, Tankless Coil, Two or More Zones Figure D-W5 Water Boiler, Indirect Water Heater Confirm that the boiler and system have no water leaks Appendix E Filling the System and Checking for LeaksNatural Gas Boilers Appendix F Adjusting Gas Input RateTable F-1 Gas Flow Rate in Cu. Ft. / Hr Appendix F Adjusting Gas Input RateLP/Propane Gas Boilers Leak Test Gas PipingAppendix G Checking Draft and Combustion IQ Option Panel Appendix H iq control systemIQ Control System Overview IQ Boiler ControlAppendix H IQ Control System EnviraCOM Thermostats IQ Display KitOptional Components Appendix H IQ Control System System Parts ListAdditional Information List Factory Mounted ComponentsService Record Limited Warranty