Burnham manual Connect Venting, ES2 Vent Connector Horizontal Length Restrictions ft

Page 9

4. Connect Venting (continued)

Table 4.1: ES2 Vent Connector - Horizontal Length Restrictions (ft)

Model

ES23

ES24

ES25

ES26

ES27

ES28

ES29

Input (MBH)

70

105

140

175

210

245

280

Minimum Vent

4

5

6

6

7

7

8

Diameter (in)

 

 

 

 

 

 

 

Vent Height (ft)

 

 

With B-Vent (double wall) Vent Connector

 

 

6

0

0

6

0

4

0

2

8

8

8

8

2

8

2

8

10

10

10

10

10

10

10

10

15

15

15

15

15

15

15

15

20

20

20

20

20

20

20

20

30

20

30

30

30

30

30

30

50

20

30

30

30

30

30

30

100

20

30

30

30

50

50

50



Image 9
Contents ES2 Page Whats in the crate? ES2 Series SpecificationsSpecifications Installation Boiler Quick-StartAppendices Position the Boiler Unpack the CrateConnect Venting Provide Combustion AirConnect Venting ES2 Vent Connector Horizontal Length Restrictions ftConnect Boiler Water Piping Connect Gas PipingDescription Burnham Part Number Connect Boiler Water Piping Connect Electrical WiringViewing the Operating Mode Options Using IQ Boiler Control DisplayOperating Mode Options Status Code Displayed in STA ModeMore Information about Adjustable Parameters Changing the Adjustable ParametersUsing the IQ Option Panel Adjustment Mode OptionsCheck for Gas and Water Leaks Using the Optional LCD Display KitBoiler restarts Perform Startup Checks and AdjustmentsAnnual Maintenance Checklist IQ Boiler Control Status Codes when Err is not displayed TroubleshootingIQ Boiler Control Error Codes when Err is flashing TroubleshootingDisplay Status Boiler / Control Actions IQ Option Panel Display Shows ERRRepair Parts List Repair Parts List Burner Orifices LP Gas 1.20mm IQ Boiler Control Jacket Vestibule Panel Supply Water Manifold Figure IW-1 Wiring Diagram Internal WiringFigure IW-2 Wiring Schematic Internal WiringFigure IW-3 Single Zone System with Domestic Hot Water Tank Figure IW-5 Multiple Zone System with Zone Valves Figure IW-7 Multiple Zone System with Zone Valve Panel Combined appliance Input BTU/hr Appendix a Combustion AirAppendix B Venting Figure B-1 Typical Atmospheric Vent Installation This page Intentionally Left Blank Length W.c. Pressure Drop Feet Appendix C Gas PipingAppendix D System Piping Appendix C Gas PipingHot Water Boilers, Non-Condensing Appendix D System PipingFigure D-0 Piping Schematic Symbols Figure D-W1 Water Boiler, Series Loop Figure D-W3 Water Boiler, Tankless Coil, Two or More Zones Figure D-W5 Water Boiler, Indirect Water Heater Confirm that the boiler and system have no water leaks Appendix E Filling the System and Checking for LeaksNatural Gas Boilers Appendix F Adjusting Gas Input RateLP/Propane Gas Boilers Appendix F Adjusting Gas Input RateLeak Test Gas Piping Table F-1 Gas Flow Rate in Cu. Ft. / HrAppendix G Checking Draft and Combustion IQ Control System Overview Appendix H iq control systemIQ Boiler Control IQ Option PanelAppendix H IQ Control System EnviraCOM Thermostats IQ Display KitAdditional Information List Appendix H IQ Control System System Parts ListFactory Mounted Components Optional ComponentsService Record Limited Warranty