Burnham ES2 manual Whats in the crate?

Page 3

Congratulations on your purchase of a new Burnham® boiler—designed and constructed to provide you with years of reliable service.

ENERGY STAR™ efficiency – friendly on the environment and your wallet.

Cast iron heat exchanger – for reliability and durability, nothing beats a cast iron heat exchanger. Ours is made proudly by our foundry in Zanesville, Ohio.

IQ Control™ – the most advanced and easiest to use control available.

System-friendlybuilt-in protection from condensation and thermal shock.

 

What's in the crate?

5. q Instruction Envelope (102625-01)

1.

q

ES2Boiler

q Instruction & Operation Manual

 

(102538-01)

2.

q

Vent Damper w/ Carton

q

Hydronics Institute Instructions

 

4” Damper ES23 (102284-01)

 

(81460061)

 

q Boiler Warranty Sheet (102198-01)

 

5” Damper ES24 (102284-02)

 

q

Equipment List (102620-01)

 

6” Damper ES25 & ES26 (102284-03)

 

 

 

7” Damper ES27 & ES28 (102284-04)

8” Damper ES29 (102284-05)

3. q Circulator & Gasket Kit

Taco 007-2 (8056170)

Grundfos UP-15 (8056173)

B & G NRF-22 (8056174)

5

4.

q Miscellaneous Parts Bag (102627-01)

1

 

q Temperature/Pressure Gage; ¼” NPT (100282-01)

qCirculator Mounting Hardware Kit, 1-

1/4” NPT (6056007)

q Circulator Wiring Harness (6130701)

 

 

q

Drain Valve; ¾” NPT (806603012)

 

 

q

Pressure Relief Valve; 30 psi

4

2

 

(81660363)

 

 

 

 

q Water Manifold for Pressure Relief/ Temp. Gage (80607001)

3

Image 3
Contents ES2 Page Whats in the crate? ES2 Series SpecificationsSpecifications Installation Boiler Quick-StartAppendices Position the Boiler Unpack the CrateConnect Venting Provide Combustion AirConnect Venting ES2 Vent Connector Horizontal Length Restrictions ftConnect Boiler Water Piping Connect Gas PipingDescription Burnham Part Number Connect Boiler Water Piping Connect Electrical WiringStatus Code Displayed in STA Mode Using IQ Boiler Control DisplayViewing the Operating Mode Options Operating Mode OptionsAdjustment Mode Options Changing the Adjustable ParametersMore Information about Adjustable Parameters Using the IQ Option PanelCheck for Gas and Water Leaks Using the Optional LCD Display KitBoiler restarts Perform Startup Checks and AdjustmentsAnnual Maintenance Checklist IQ Boiler Control Status Codes when Err is not displayed TroubleshootingIQ Boiler Control Error Codes when Err is flashing TroubleshootingDisplay Status Boiler / Control Actions IQ Option Panel Display Shows ERRRepair Parts List Repair Parts List Burner Orifices LP Gas 1.20mm IQ Boiler Control Jacket Vestibule Panel Supply Water Manifold Figure IW-1 Wiring Diagram Internal WiringFigure IW-2 Wiring Schematic Internal WiringFigure IW-3 Single Zone System with Domestic Hot Water Tank Figure IW-5 Multiple Zone System with Zone Valves Figure IW-7 Multiple Zone System with Zone Valve Panel Combined appliance Input BTU/hr Appendix a Combustion AirAppendix B Venting Figure B-1 Typical Atmospheric Vent Installation This page Intentionally Left Blank Length W.c. Pressure Drop Feet Appendix C Gas PipingAppendix D System Piping Appendix C Gas PipingHot Water Boilers, Non-Condensing Appendix D System PipingFigure D-0 Piping Schematic Symbols Figure D-W1 Water Boiler, Series Loop Figure D-W3 Water Boiler, Tankless Coil, Two or More Zones Figure D-W5 Water Boiler, Indirect Water Heater Confirm that the boiler and system have no water leaks Appendix E Filling the System and Checking for LeaksNatural Gas Boilers Appendix F Adjusting Gas Input RateTable F-1 Gas Flow Rate in Cu. Ft. / Hr Appendix F Adjusting Gas Input RateLP/Propane Gas Boilers Leak Test Gas PipingAppendix G Checking Draft and Combustion IQ Option Panel Appendix H iq control systemIQ Control System Overview IQ Boiler ControlAppendix H IQ Control System EnviraCOM Thermostats IQ Display KitOptional Components Appendix H IQ Control System System Parts ListAdditional Information List Factory Mounted ComponentsService Record Limited Warranty