Crown Boiler 24-04, 24-11, 24-10, 24-08, 24-12, 24-06, 24-05, 24-09, 24-03, 24-07 Boiler

Page 68

 

BUSHING BLK 1/4-1 X 1/2-1

047-95

 

 

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSHING BLK 1 X 1/2-1

950185

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSHING BLK 3/4 X 1/2-1

096-95

1

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

214-13 CONBRACO

950525

 

 

 

 

 

 

1

1

1

1

 

 

VALVE, SAFETY PSI 15

 

 

 

 

 

 

 

 

 

 

 

 

 

213-13 CONBRACO

950520

 

 

1

1

1

1

 

 

 

 

 

 

VALVE, SAFETY PSI 15

 

 

 

 

 

 

 

 

 

 

 

 

 

202-13 CONBRACO

950515

 

1

 

 

 

 

 

 

 

 

 

 

VALVE, SAFETY PSI 15

 

 

 

 

 

 

 

 

 

 

 

 

 

211-13 CONBRACO

950510

1

 

 

 

 

 

 

 

 

 

1

(BECKETT)

VALVE, SAFETY PSI 15

 

 

 

 

 

 

 

 

 

 

 

 

PLUG BLACK 4"

950274

1

1

11

11

1

1

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSHING 1 X 1/4 1

950192

 

 

 

 

 

 

 

 

 

 

 

ASSY

 

 

 

 

 

 

 

 

 

 

 

 

 

BUSHING 3/4 X 1/4 1

950098

1

1

1

 

1

 

 

1

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CARTON

INSTRUCTIONS NOZZLE

980419

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOZZLE 00/45P.8 HAGO

130190

 

 

 

 

1

 

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILER

NOZZLE 00/45P.5 HAGO

074-13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOZZLE 50/45P.4 HAGO

130185

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STEAM

SCREWS

212-90

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

1 2

METAL SHEET 1/2" X #10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLATE LEVEL

980150

 

 

 

 

 

 

 

 

 

 

 

 

WATER SAFE MINIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAUGE NIPPLE

980920

1

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY

980418

1

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL INSTALLATION

980417

1

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLATE RATING

111-98

1

1

1

1

1

1

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESCRIPTION

CROWN PART #

24-03SO

24-04SO

24-05SO

24-06SO

24-07SO

24-08SO

24-09SO

24-10SO

24-11SO

24-12SO

24-03SG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1 1 1

1

1 1

1 1 1 1

1

1

1 1

 

1 1 1 1

1

 

24-04SG 1 1 1 1 1 2 24-05SG 1 1 1 1 1 2 24-06SG 1 1 1 1 1 2 24-07SG 1 1 1 1 1 2 24-08SG 1 1 1 1 1 2 24-09SG 1 1 1 1 1 2 24-10SG 1 1 1 1 1 2

68

Image 68
Contents Series Page Important Information Read Carefully Page Page Table of Contents Table of Contents Section I General Information Boiler RATINGS/DATA Section I General Information Locate the UnitBoiler Foundation Chimney or VentVents Faults & Suggestions Section II Cast Iron Block Assembly Assembly of Sections Manual DRAW- UPNipple Gauge Series 24 Section Arrangement Draw-Up Rods Alternating Pattern Manual Draw-up Center Section Channel Block Position Partial Block Draw-Up Hydraulic Draw-Up of Sections Section III Installation Instructions Canopy with Rear Flue Outlet Damper AssemblyBare Boiler Assembly Avoid Breathing Fiber Particulates and Dust Left Side Canopy Intermediate Bracket Mount Rear Observation Port Cover Refer to Figure Inspect ALL Boiler SealsSeries 24 Jacket Assembly Boiler Models 24-03 thru Burner Mounting Plate Refer to Figures 16 Mount Burner Adapter Plate to Burner Mounting PlatePurpose of Tappings Steam Boilers Steam Trim Steam Boilers Install Steam Trim This Is Intentionally Left Blank Purpose of Tappings Water Boilers Water Trim Boiler Piping Heating Applications Water Boilers Install Water TrimBurner Installation Page Parallel Piping Conversion Recommendation 1 Use when Recommendation 2 Use when Recommendation 3 Use when Page Page Page BMounting Elevations M&M 150, 64 Float Low Water Cut-offs Schematic Tankless Heater Piping 24-08 24-09 Return Temperature Control and Components CCW Open to SystemWater Boiler Pressure Relief Valve Hook-Up Typical Boiler Wiring with RTC Front Typical Boiler with RTC Return Sensor Rear Always Inspect Installation Before Section IV Operating InstructionsStarting Burner Fill Heating System with WaterFlame Failure Boil MIN Delay Test Controls Check Operation of High Limit ControlBoiler and System Cleaning Steam Boiler Boiler and System Cleaning Water Boilers Frequent Water Addition Oxygen CorrosionSection V Service Instructions Clean the Boiler FluewaysMaintenance of LOW Water Cutoff Devices General Maintenance Considerations OperationSection VI Burner Specifications OIL BurnersSection VII Repair Parts & Carton Contents Series 24 Master Parts List Section VII Repair Parts Jacket Carton Bare Boiler Assembly Section Joiner Carton Assy Rear Target Wall Carton Standard Steam Trim Carton Assy RTC Carton with Outdoor Reset Tankless Coil Components Boiler Water Section Viii Appendix Page Mechanical Page Mechanical Electrical Page Page Page Page Page Page Page Page Series 24 Boiler Circulator Selection Taco 20F Differential Boiler Recirculation Grundfos Circulating Pump Way Boiler Recirculation Bell and Gossett Circulating Pump Way Boiler Recirculation Armstrong Circulating Pump Way Appendix C Valve and Actuator Mounting Instructions ApplicationService Record PN 980417 S24 12/05