TABLE I
BOILER RATINGS/DATA
(1) |
|
|
| (2) |
|
|
|
|
| (3) | (4) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Net I=B=R Rating | Burner | Heating | Net | Pressure | Water | Boiler Weight |
| ||||||
|
| Gross | Surface | Content | w/ Water | Vent | ||||||||||
Boiler | Horse- |
|
|
| Input | (Sq. Ft.) | Firebox | in | (Gal.) | (Lbs.) | ||||||
Model | Power | Output |
|
|
|
|
|
|
| Volume | Firebox |
|
|
|
| Dia. |
|
| (MBH) | Sq. Ft. | MBH | MBH | Oil | Gas | Steam | Water | (Cu.Ft.) | ("W.C.) | Steam | Water | Steam | Water | (In.) |
|
|
| Steam | Steam | Water | (GPH) | (MBH) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10.2 | 342 | 1071 | 257 | 297 | 3.05 | 438 | 34.2 | 37.0 | 3.2 | .33 | 44.5 | 66.0 | 1439 | 1618 | 7 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14.1 | 471 | 1471 | 353 | 410 | 4.10 | 594 | 48.6 | 54.3 | 4.8 | .38 | 53.0 | 75.0 | 1811 | 1995 | 7 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18.9 | 634 | 1983 | 476 | 551 | 5.50 | 792 | 63.0 | 71.5 | 6.4 | .31 | 61.5 | 84.0 | 2184 | 2372 | 8 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
23.8 | 797 | 2492 | 598 | 693 | 6.90 | 990 | 77.5 | 88.8 | 7.9 | .38 | 70.0 | 93.0 | 2557 | 2749 | 8 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
28.0 | 937 | 2929 | 703 | 815 | 8.10 | 1174 | 91.9 | 106.0 | 9.5 | .36 | 78.5 | 102.0 | 2930 | 3126 | 8 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
32.5 | 1087 | 3396 | 815 | 945 | 9.40 | 1358 | 106.3 | 123.3 | 11.0 | .35 | 87.0 | 111.0 | 3303 | 3503 | 10 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
39.3 | 1316 | 4146 | 995 | 1148 | 11.40 | 1641 | 120.7 | 140.5 | 12.6 | .35 | 95.5 | 120.0 | 3676 | 3880 | 10 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
45.0 | 1505 | 4788 | 1149 | 1309 | 13.00 | 1867 | 135.1 | 157.8 | 14.2 | .40 | 104.0 | 129.0 | 4048 | 4257 | 10 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50.5 | 1690 | 5429 | 1303 | 1470 | 14.60 | 2093 | 149.5 | 175.0 | 15.7 | .45 | 112.5 | 138.0 | 4421 | 4634 | 12 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
55.3 | 1852 | 5983 | 1436 | 1610 | 16.00 | 2320 | 164.0 | 192.3 | 17.3 | .49 | 121.0 | 147.0 | 4794 | 5011 | 12 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1)Trim Suffix: S = Steam Boiler, W = Water Boiler
Fuel Suffix: N = Natural Gas, P = LP Gas, O = Oil
(2)I=B=R net ratings shown are based on piping and
(3)Firebox volume does not include added volume of 8” extended burner mounting plate (BMP). If 8” BMP is specified (refer to Figure 1), add 0.7 cu. ft. to volume listed above.
(4)Boiler ratings are based on 12.5% CO2 (oil) and 9.7% CO2 (natural gas), + .10” (inches) water column pressure at boiler flue outlet. Ratings shown above apply at altitudes up to 1000 feet on oil and 2000 feet on gas.
For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Maximum Allowable Working Pressure: Steam Boiler - 15 PSI, Water Boiler - 50 PSI
Standard Safety (Relief) Valve Set Pressure: Steam Boiler - 15 PSI, Water Boiler - 30 PSI
9