11.Shall have a battery
12.Shall have
13.Shall include an
14.Software upgrades will be accomplished by either local or remote download. No software upgrades through chip replacements are allowed.
23 09 33 Electric and Electronic Control System for HVAC
23 09 33.13 Decentralized, Rooftop Units:
23 09 33.13.A. General:
1.Shall be complete with
2.Shall utilize
3.Shall include a central control terminal board to conveniently and safely provide connection points for vital con- trol functions such as: smoke detectors, phase monitor, gas controller, economizer, thermostat, DDC control op- tions, and low and high pressure switches.
4.The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. See heat exchanger section of this specification.
5.Unit shall include a minimum of one
23 09 33.23.B. Safeties:
1.Compressor
2.Low pressure switch.
a.Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pres- sure switches. They shall physically prevent the
b.Low pressure switch shall use different color wire than the high pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit.
3.High pressure switch.
a.Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pres- sure switches. They shall physically prevent the
b.High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit.
4.Automatic reset, motor thermal overload protector.
5.Heating section shall be provided with the following minimum protections:
a.High temperature limit switches.
b.Induced draft motor speed sensor.
c.Flame rollout switch.
d.Flame proving controls.
23 09 93 Sequence of Operations for HVAC Controls
23 09 93.13 Decentralized, Rooftop Units:
23 09 93.13 INSERT SEQUENCE OF OPERATION
23 40 13 Panel Air Filters
23 40 13.13 Decentralized, Rooftop Units:
23 40 13.13.A. Standard filter section
1.Shall consist of factory installed, low velocity, disposable
2.Unit shall use only one filter size. Multiple sizes are not acceptable.
3.Filters shall be accessible through an access panel with
23 81 19 Self-Contained Air Conditioners
23 81 19.13
23 81 19.13.A. General
1.Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll com- pressor(s) for cooling duty and gas combustion for heating duty.
580J