Baxi Potterton Gold FSB 30 HE To it Fig, Remove the gas injector pipe from the gas valve, Base

Page 41

Flue Sampling Point

Fig. 41a

Injector Pipe

Injector Pipe Retaining

Screw

14.0Servicing the Boiler

14.2Annual Servicing - Inspection (Cont)

7.To clean the heat exchanger and burner proceed as follows:

a)Disconnect the electrical leads to the fan component protection sensor (Fig. 42).

b)Loosen the screw retaining the gas injector pipe at the venturi (Fig. 42).

c)Undo the two wing nuts to disconnect the fan

(Fig. 42).

d) Remove the fan and disconnect the electrical supply

to it (Fig. 42).

e) Remove the gas injector pipe from the gas valve

(push-fit) (Fig. 42).

f) Remove the condensate trap drain plug and place a

vessel underneath to catch the condensate (care should

be taken as this could be hot). The condensate drain

pipe may be removed to increase access.

Protection

Sensor Leads

Securing Nut

Fan

Sensor

Leads

Electrical Supply

g) Undo the condensate trap securing nut, lock nut and

the condensate drain pipe. Remove the condensate trap

and disconnect the sensor leads (Fig. 43). Clean the trap

and refit the drain plug.

h) Remove the two screws securing the burner and

remove the burner. Visually inspect the internal burner

baffle for obstruction, check seal around baffle for

cracks/damage. Clean with a soft brush.

 

 

Condensate

Fig. 42

Wing Nuts

Trap

 

 

Lock Nut

Service Drain

Plug

Central Insulation Panel

Trap to Condensate

Pump Inlet Pipe

 

Fig. 43

Burner

Combustion

Box Base

Heat Exchanger

Support Bracket

Combustion Box Base

i) Loosen the two screws retaining the heat exchanger

support bracket and slide to the left to remove

(Fig. 44).

j) Remove the four screws securing the heat

exchanger/combustion box base and withdraw the

base.

k) Lower the central insulation panel and check

condition (Fig. 44). Replace the lower insulation pad if

necessary.

l) Ensure the heat exchanger fins are clear of any

obstruction.

m) Check condition of all seals. Important: Pay

particular attention to the condition of the

combustion box door seals.

n) Reassemble in reverse order and check for leaks.

8.

Check the operation of the condensate pump and

drain pipework (see Section 10.1)

9.

Check CO/CO2 ratio at flue sampling point (Fig.41a).

See section 4.0.

Burner Securing

Screws

Securing Screws

Fig. 44

10. Complete the relevant Service Interval Record

section of the Benchmark Commissioning Checklist at

the rear of this publication and then hand it back to the

© Baxi Heating UK Ltd 2011

user.41

Image 41
Contents FSB 30 HE Potterton Gold FSB 30 HE No 592 Natural GasScheme Members only Installer Notification GuidelinesGas Safety Installation & Use Regulations Important Installation, Commissioning, Service & RepairLegislation Codes of Practice, most recent version should be usedContents Important Information IntroductionDescription Position of Optional Integral Timer Wiring Flow Temperature Thermistor RedGeneral Layout Layout Figs , 4, 5All TRVs Shut Down ? Minute Anti-cycle Boiler OperationBoiler Operation Ipxx Technical DataCAT I 2H Dimensions and Fixings Treatment of Water Circulating Systems System DetailsWater Circulating Systems Air Vents Low Head InstallationPipework System Controls & Wiring Sealed Systems Fig Compartment Site RequirementsLocation Gas Supply Clearances Figs &16Electrical Supply 5mm Min 500mm Min For Servicing Purposes 390mmCondensate Disposal Condensate Drain GeneralSink Site Requirement± 10 from vertical Blockage or restriction of the pipe into the drainMIN FlueHorizontal Flue System Examples Flue OptionsHorizontal Flue Systems This bend is equivalent to 0.5 metreTwin & Vertical Flue Systems Vertical Flue System Examples Twin PipeTotal equivalent length 17.2 + 34.4 = 51.6 metresCDS Flue AccessoriesFlue Group B Flue Group PFor Twin Flues For Vertical Flues For Vertical Flue SystemsFor Twin Flue Systems For Roof Terminals Flue DimensionsTerminal Guard Fig Flue Deflector aPlume Displacement Kit P.D.K Plume DisplacementDetermining Permissible Lengths P.D.K This section of the flue Must be horizontal General Fitting Notes P.D.KMin metres Min .3 metres Fig. H Installation Flue Inner Flue Support Bracket Fitting the Standard FluePoints Inner Flue Support Bracket Flue Elbow Gasket Flue TrimConnection Making the Condensate DrainIntegral Programmer Making The Electrical ConnectionsCable Clamp Way Terminal Block Electrical Schematic Wiring DiagramGreen/Yellow Fuse 3.15 ATPCB Illustrated Wiring DiagramPriming the Condensate Pump Commissioning the BoilerCommissioning the Boiler Check the Operational Working Gas Inlet Pressure Completion 13.2 ‘Benchmark’ ChecklistFitting The Case Panels & Facia HandoverAnnual Servicing Servicing the BoilerAir Box Door Panel Spark Sleeve Annual Servicing InspectionEarth Combustion Box Door Panel InsulationCracks/damage. Clean with a soft brush Pipe may be removed to increase accessLock Nut Service Drain Plug Central Insulation Panel To it FigChanging Components & Preparation Flow Temperature Thermistor and Safety Thermostat FigChanging Components Clip Condensate Pump Complete aDrain the boiler see .1 paragraph 2 Check operation of the pump See SectionChanging Components Spark and Sensing Electrodes Fig Gas Valve Fig Injector Pipe FigCondensate Trap Fig Securing Nut Sensor Leads Condensate Trap Lock NutCombustion Box Door Panel Burner Support Bracket Heat Exchanger Manifold AssemblyHeat Exchanger Burner Securing Screws Key Description Short Parts ListShort Parts List Fault Finding 240V at B ? 240V at a ?240V at C ? 240V at D ?Viewed from Wire Entry end Replace Flow Switch Wires from inline Connector to PCB faultySystem full of water ? Pump running ?Rectify wiring Wiring from PCBReplace PCB Way Connector Lead from PCB to Gas Valve faulty Is there Gas at gas valve inlet ?Lights On Off Replace Stat Replace fan Lights Rectify wiring Viewed from Wire Entry end YES ‘C’ ‘D’ ‘B’‘A’ Condensing Boilers only Service Record Brooks House, Coventry Road, Warwick. CV34 4LL Comp No 6/11 Potterton

Gold FSB 30 HE specifications

The Baxi Potterton Gold FSB 30 HE is a high-efficiency system boiler designed to meet the demands of modern homes while providing exceptional performance and reliability. As part of the Baxi Potterton Gold range, this model combines advanced engineering with user-friendly features, making it a top choice for homeowners and installers alike.

One of the primary features of the Baxi Potterton Gold FSB 30 HE is its impressive efficiency rating. With an ErP rating of A for heat and a seasonal efficiency of up to 90%, this boiler not only reduces energy consumption but also helps in lowering utility bills. The high-efficiency design ensures that more of the fuel consumed is converted into usable heat, making it an environmentally friendly option.

The boiler utilizes a lightweight design, weighing in at just 30 kg, which makes it easy to transport and install. Its compact size allows for flexibility in siting, meaning it can fit comfortably in kitchen cupboards or utility rooms without taking up excessive space. The small footprint caters to property owners looking to save on installation areas while still having a powerful heating system.

In terms of technology, the Baxi Potterton Gold FSB 30 HE features an integral thermostat and a user-friendly LCD display for easy boiler operation and maintenance. This advanced control system provides homeowners with accurate temperature readings and the ability to adjust settings with ease. The built-in diagnostics feature simplifies fault-finding and allows for quick resolutions, minimizing downtime.

The boiler is also equipped with weather compensation technology, which adjusts the heating output based on the external temperature. This ensures optimal performance year-round, maintaining a comfortable environment inside the home and optimizing energy use.

Safety features are paramount in the design of the Baxi Potterton Gold FSB 30 HE. It includes a range of built-in safeguards, such as a frost protection mode and an overheat thermostat, giving users peace of mind. Moreover, it is compatible with various heating controls and can be linked to smart home systems, offering further convenience and energy-saving options.

Overall, the Baxi Potterton Gold FSB 30 HE stands out for its efficiency, compact design, and advanced technology, making it a reliable solution for domestic heating needs. With a solid reputation for quality and performance, the Gold FSB 30 HE continues to be a favored choice for those looking to invest in an effective system boiler.