State Industries Green Choice instruction manual

Page 12

4.First remove the 3” (76 mm) horizontal extension from the elbow. Start- ing with the long end (with four securing holes), place the 6” (152 mm) diameter vent elbow over the 3” (76 mm) diameter elbow. Bend the round end “oval” to fit the flared oval end of the jacket top.

FIGURE18.

5.Making sure the 6” (152 mm) diameter elbow is centered around the 3” (76 mm) diameter flue, secure the 6” (152 mm) diameter vent pipe using four sheet metal screws at the connection of the jacket top.

FIGURE 19 .

6.The standard vent kit includes a 6” (152 mm) diameter extension pipe which is used when “E” dimension is over 6 1/2” (165 mm).

FIGURE 20.

7. If “E” dimension is less than 6 1/2” (165 mm) move to next step.

If “E” dimension is over 6 1/2” (165 mm), assemble the 6” (152 mm) diameter extension pipe (crimped end) to the 6” (152 mm) diameter vent elbow and secure using two sheet metal screws.Apply an ample amount of sealant around the joint to ensure a good seal.

FIGURE21.

8.Slide the vent collar (to be installed later) over the 6” (152 mm) vent elbow.

FIGURE22.

9.Place the water heater at the opening in the wall, at the predetermined clearance.

FIGURE23.

10.Move outdoors with all the remaining vent parts. Using the tube of sealant supplied, run an ample amount on the inside surface of the collar assembly that will contact the exterior wall and also fill the bead on the end of the 6” ((152 mm) diameter vent collar.

FIGURE24.

12

Image 12
Contents Residential Direct Vent GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installation GET to Know Your Water Heater GAS ModelsMixing Valve Usage Locating the NEW Water Heater Facts to Consider about the LocationCombustion Air and Ventilation Venting Clearances Optional Wire Grill Flue ExtensionsChart #1 Chart #2Vertical Height Extension Kit Horizontal Extension KitALL Installations Standard Vent Kit Installation #1Cutting The Opening Through The Outside Wall Water Heater AttitudePage Page Chart #3 GAL CAP BTU’s in 1000’s NAT./L.PPage Page Optional Horizontal Vent Kit Installation #3 Page Optional Vertical and Horizontal Vent Kit Installation #4 Through The Outside Wall. SeeChart #4 GAL CAP Collar Optional Vent Cap Porcelain-Enameled Page Page Installing the NEW Water Heater Water PipingTEMPERATURE-PRESSURE Relief Valve Valve and Pipe InsulationFilling the Water Heater GAS Piping GAS Piping with Flexible Connector Sediment TrapsGAS Piping with ALL Black Iron Pipe to GAS Control Installation Checklist Before Lighting the PilotPage Temperature Regulation For Your InformationStart UP Conditions CondensateOperational Conditions Periodic Maintenance Burner CleaningGAS Control Valve & Burner Assembly Venting System InspectionTEMPERATURE-PRESSURE Relief Valve Operation HousekeepingAnode ROD Inspection DrainingDrain Valve Washer Replacement Leakage CheckpointsRepair Parts List Parts GAL. CAP KEY # Description BTU’s in 1000’s NAT/L.P 36/36 38/38 40/40 48/44 55 NATRepair Parts List This is a Repair Parts LIST, not a Packing List BTU’s in 1000’s NAT/L.P 36/36 38/38 40/40 48/44Troubleshooting Guidelines Page Page