8. Be sure the 6” (15.2 cm) diameter elbow is centered around the 3” | 11. Slide the 6” (15.2 cm) telescoping vent section apart to expose the |
(7.6 cm) diameter flue, secure using two sheet metal screws at the | beads. Use the supplied tube of caulking and fill the exposed beads. |
connection of the elbow and the 6”(15.2 cm) vertical extension. |
|
FIGURE 82.
12. Insert the 6” (15.2 cm) telescoping vent section into the wall.
FIGURE79.
9. Slide the vent collar(to be installed later)over the 6” (15.2cm) vent elbow.
FIGURE 83.
13. The remaining vent parts will be installed from the outside. Apply ample amount of sealant to the inside surface of the collar assembly that will contact the exterior wall. Also, apply sealant to the bead around the outside edge at the end of the 6” (15.2 cm) diameter vent
FIGURE80.collar.
10. Move the water heater into position at the vent opening.
FIGURE 84.
14. Install the vent collar assembly through the wall, connecting to the 6” (15.2 cm) telescoping extension. Remember, the extension is not connected and may be necessary to return indoors to push the extension back against the interior wall for a tight fit to the collar.
FIGURE81. | FIGURE85. |
21