7.Place the waterheater at the opening in the wall at the predetermined clearance.

FIGURE58.

8.Slide the 6” (152 mm) telescoping vent section apart to expose the beads. Use the supplied tube of sealant and fill the exposed beads.

FIGURE59.

9.Insert the 6” (152 mm) telescoping vent section into the opening in the wall.

FIGURE60.

10.The remaining vent parts will be installed from the outside. Apply ample amount of sealant to the inside surface of the collar assembly that will contact the exterior wall. Also, apply sealant to the bead around the outside edge at the end of the 6” (152 mm) diameter vent collar.

FIGURE61.

11.Insert the vent collar assembly through the wall opening, connect- ing to the 6” (152 mm) telescoping extension. Remember, the vent extension has not been connected so it may be necessary to go back outdoors and push it back up into the wall opening for a tight fit to the collar.

FIGURE62.

12.Four wood screws were supplied to temporarily attach the collar to the exterior wall of the building. However, you may have to substi- tute other types of screws depending on the construction material of the exterior wall.

FIGURE 63.

13. Insert the vent cap into the vent collar assembly.

FIGURE 64.

14.The vent cap has four holes around the outer edge. Remove the four screws used to temporarily attach the collar to the exterior wall. Then secure the vent cap assembly with the vent collar assembly to the exterior wall using the same screws.

Note: Screws are supplied; however, substitution may be necessary depending on the exterior wall material.

FIGURE65.

15.The remainder of the installation will be indoors to complete the assembly process.

18

Image 18
Contents Residential Direct Vent GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionTypical Installation GET to Know Your Water Heater GAS ModelsMixing Valve Usage Locating the NEW Water Heater Facts to Consider about the LocationCombustion Air and Ventilation Venting ClearancesOptional Wire Grill Flue ExtensionsVertical Height Extension Kit Chart #1Chart #2 Horizontal Extension KitCutting The Opening Through The Outside Wall ALL InstallationsStandard Vent Kit Installation #1 Water Heater AttitudePage Page Chart #3 GAL CAP BTU’s in 1000’s NAT./L.PPage Page Optional Horizontal Vent Kit Installation #3 Page Optional Vertical and Horizontal Vent Kit Installation #4 Through The Outside Wall. SeeChart #4 GAL CAP Collar Optional Vent Cap Porcelain-Enameled Page Page Installing the NEW Water Heater Water PipingTEMPERATURE-PRESSURE Relief Valve Valve and Pipe InsulationFilling the Water Heater GAS Piping GAS Piping with Flexible Connector Sediment TrapsGAS Piping with ALL Black Iron Pipe to GAS Control Installation Checklist Before Lighting the PilotPage Start UP Conditions Temperature RegulationFor Your Information CondensateOperational Conditions GAS Control Valve & Burner Assembly Periodic MaintenanceBurner Cleaning Venting System InspectionAnode ROD Inspection TEMPERATURE-PRESSURE Relief Valve OperationHousekeeping DrainingDrain Valve Washer Replacement Leakage CheckpointsRepair Parts List Parts GAL. CAP KEY # Description BTU’s in 1000’s NAT/L.P 36/36 38/38 40/40 48/44 55 NATRepair Parts List This is a Repair Parts LIST, not a Packing List BTU’s in 1000’s NAT/L.P 36/36 38/38 40/40 48/44Troubleshooting Guidelines Page Page