Bradford-White Corp BWCH, BWCV, Copper Brute II Hydronic Boiler warranty Gas Train Components

Page 58

Item

Description

Model

Model

Model

Model

Model

Model

Model

 

 

500

750

1000

1250

1500

1750

2000

71

High Limit, Manual Reset, BWCH

RE0015900

RE0015900

RE0015900

RE0015900

RE0015900

RE0015900

RE0015900

 

 

 

 

 

 

 

 

 

High Limit, Manual Reset, BWCV, 210F Max. E2217800

E2217800

E2217800

E2217800

E2217800

E2217800

E2217800

72

 

 

 

 

 

 

 

 

Relay, Pump (SPST)

E0098300

E0098300

E0098300

E0098300

E0098300

E0098300

E0098300

 

 

 

 

 

 

 

 

 

 

Relay, Fan (DPDT)

 

 

 

E0076600

E0076600

E0076600

E0076600

 

 

 

 

 

(2)

(2)

(2)

(2)

73

 

 

 

 

 

 

 

 

Terminal Bus (12 Position)

E2342600

E2342600

E2342600

E2342600

E2342600

E2342600

E2342600

74

 

 

 

 

 

 

 

 

Transformer

E2310400

E2310400

E2310400

E2312800

E2312800

E2312800

E2312800

 

 

 

 

 

(2)

(2)

(2)

(2)

75A

 

 

 

 

 

 

 

 

Circuit Breaker, non-CSD-1

E22106200

E22106200

E22106200

E2318800

E2318800

E2318900

E2318900

 

 

 

 

 

 

 

 

 

 

Circuit Breaker, CSD-1

E22106200

E2318800

E2318800

E2318900

E2318900

E2318900

E2318900

75B

 

 

 

 

 

 

 

 

Switch, Rocker, 30A 125VAC

E2343300

E2343300

E2343300

E2343300

E2343300

E2343300

E2343300

 

 

 

 

 

 

 

 

 

 

Sensor, Universal (shipped loose)

R2014800

R2014800

R2014800

R2014800

R2014800

R2014800

R2014800

 

 

 

 

 

 

 

 

 

 

Gas Train Components

 

 

 

 

 

 

 

 

See Figure 34

 

 

 

 

 

 

 

76

 

 

 

 

 

 

 

 

Manifold, Gas Supply

5C6700

7C6700

10C6700

12C6700

15C6700

17C6700

20C6700

77

 

 

 

 

 

 

 

 

Valve, Ball

V2003100

V2003100

V2003200

V2003300

V2003300

V2003300

V2003300

 

 

 

 

 

 

 

 

 

Burner Trays

Note: Burner Manifold Assemblies contain item numbers 78 through 81.

Burner Manifold Assy, 3 Burners, Right, Nat

5C6600

5C6600

5C6600

5C6600

5C6600

 

 

 

(1)

(1)

(2)

(1)

(1)

 

 

 

 

 

 

 

 

Burner Manifold Assy, 3 Burners, Left, Nat

5C6500

5C6500

5C6500

5C6500

5C6500

 

 

 

(1)

(2)

(3)

(1)

(2)

 

 

 

 

 

 

 

 

Burner Manifold Assy, 4 Burners, Right, Nat

 

10C6600

 

10C6600

10C6600

10C6600

 

 

 

(1)

 

(1)

(1)

(2)

 

 

 

 

 

 

 

 

Burner Manifold Assy, 4

Burners, Left, Nat

 

10C6500

 

10C6500

10C6500

10C6500

 

 

 

(2)

 

(2)

(2)

(4)

 

 

 

 

 

 

 

 

Burner Manifold Assy, 3

Burners, Right, LP

5C6620

5C6620

5C6620

5C6620

5C6600

 

 

 

(1)

(1)

(2)

(1)

(1)

 

 

 

 

 

 

 

 

 

Burner Manifold Assy, 3

Burners, Left, LP

5C6520

5C6520

5C6520

5C6520

5C6500

 

 

 

(1)

(1)

(3)

(1)

(2)

 

 

 

 

 

 

 

 

 

Burner Manifold Assy, 4

Burners, Right, LP

 

10C6620

 

10C6620

10C6620

10C6620

 

 

 

(1)

 

(1)

(1)

(2)

 

 

 

 

 

 

 

 

Page 58

BRADFORD WHITE CORP.

Image 58
Contents Copper Brute Table of Contents Replacement Parts MaintenanceTrouble Shooting Operating InstructionsIntroduction General InformationModel Identification Dimensions WarrantyLocating the Appliance Dimensional Data Inches 91cm horizontally Combustion Air From Room Venting and Combustion AirCombustion Air Intake Combustion AirCategory I Vent VentingVent Categories Common Venting SystemsCombustion Air and Vent Through Side Wall Side Wall Vent Terminal Locating Vent & Combustion Air TerminalsCategory III Vent Side Wall Combustion Air TerminalVertical Vent Terminal Common Vent Test BoilersVent Terminals for Outdoor Units Vertical Combustion Air TerminalGas Supply and Piping 61-91m4A.2 Cold Water Make-Up Boiler Water Connections Copper Brute II Boiler4A.1 Heating System Piping Hot Supply Connections Boiler 4A.3 Water Flow Requirements BoilerHydronic Piping Multiple Boilers, Primary Secondary System Hydronic Piping Multiple Boilers, Low Temperature System Hydronic Piping One Boiler, Multi-Temperature System Hydronic Piping Primary-Secondary, Reverse-Return Boiler CIRC. Pump Sized for Flow Through Boiler 4B.2 Hot Water Supply Piping Water Heater Water Connections Copper Brute II Water Heater4B.1 Water System Piping Water Heater 4B.3 Water Flow Requirements Water Heater4B.5 Freeze Protection Water Heater SupplyWater Heater Piping Multiple Heaters, One Tank Water Heater Piping Multiple Heaters, Multiple Tanks Temperature Control Main PowerElectrical Connections Field Wiring Panel External Staging Control Wiring AvertissementCopper Brute II 500 750 Ladder Diagram Copper Brute II 1000 Ladder Diagram Copper Brute II 1250 2000 Ladder Diagram Copper Brute II 500 1000 Wiring Schematic Copper Brute II 1250 1500 Wiring Schematic Copper Brute II 1750 2000 Wiring Schematic Terminal designations are as indicated Field Wiring for Modes 1 Avertissement Sequence of Operation Operating InstructionsFilling the Boiler System System Piping Primary Secondary Piping Programming the Temperature ControlChoosing the Mode Parallel PipingFor ALL Other Modes Hydronic Primary/Secondary Mode Choosing the Mode for your Application Mechanical aquastat in a domestic hot water storage tankMode 5 Primary secondary piping with outdoor reset Advanced Topics Staging ModeDifferential Boiler Maximum Boil MAX Boiler Target TemperatureBoiler Minimum Boil MIN Pump OperationSetpoint Operation Outdoor Reset OperationDedicated Domestic Hot Water Typical Gas Train Configuration Set Up for 0 to 2500 Feet Altitude Operating the Burner and Set UpAdvanced Programming Mode External Boiler OperationShutting Down the Copper Brute High Altitude Adjustment and Set UpTo Restart the Copper Brute System Maintenance MaintenanceAppliance Maintenance Component Description Ignition Controls Temperature ControlFlow Switch IgnitorsBradford White Corp Trouble Shooting Troubleshooting the Temperature Control Troubleshooting Copper Brute ControlsCopper Brute II 500 Troubleshooting Error Codes Replacement Parts Parts ListSee Figures 35 Heat Exchanger Components Electrical Components Gas Train Components Burner Manifold Assy, 4 Burners, Left, LP For reference Internal Components Copper Brute II Hydronic Electrical Components H2214401F