Bradford-White Corp Copper Brute II Hydronic Boiler Burner Manifold Assy, 4 Burners, Left, LP

Page 59

Item

Description

Model

Model

Model

Model

Model

Model

Model

 

 

500

750

1000

1250

1500

1750

2000

 

Burner Manifold Assy, 4 Burners, Left, LP

 

 

10C6520

 

10C6500

10C6520

10C6520

 

 

 

 

(2)

 

(2)

(2)

(4)

78

 

 

 

 

 

 

 

 

Valve, Gas, Combination

V2017600

V2017600

V2017600

V2017600

V2017600

V2017600

V2017600

 

 

(2)

(3)

(3)

(5)

(5)

(6)

(6)

79

 

 

 

 

 

 

 

 

Valve, Manual Shutoff

V2000200

V2000200

V2000200

V2000200

V2000200

V2000200

V2000200

 

 

(2)

(3)

(3)

(5)

(5)

(6)

(6)

80

 

 

 

 

 

 

 

 

Orifice, Gas, Natural

L2013000

L2013000

L2013000

L2013000

L2013000

L2013000

L2013000

 

 

(6)

(9)

(12)

(15)

(18)

(21)

(24)

 

 

 

 

 

 

 

 

 

 

Orifice, Gas, Propane

L2012400

L2012400

L2012400

L2012400

L2012400

L2012400

L2012400

 

 

(6)

(9)

(12)

(15)

(18)

(21)

(24)

81

 

 

 

 

 

 

 

 

Burner Manifold, 3 Burners, Right

L2012900

L2012900

 

L2012900

L2012900

L2012900

 

 

 

(1)

(1)

 

(2)

(1)

(1)

 

 

 

 

 

 

 

 

 

 

 

Burner Manifold, 3 Burners, Left

L2012800

L2012800

 

L2012800

L2012800

L2012800

 

 

 

(1)

(1)

 

(3)

(1)

(2)

 

 

 

 

 

 

 

 

 

 

 

Burner Manifold, 4 Burners, Right

 

 

L2012700

 

L2012700

L2012700

L2012700

 

 

 

 

(1)

 

(1)

(1)

(2)

 

 

 

 

 

 

 

 

 

 

Burner Manifold, 4 Burners, Left

 

 

L2012600

 

L2012600

L2012600

L2012600

 

 

 

 

(2)

 

(2)

(2)

(4)

82

 

 

 

 

 

 

 

 

Burner Tray, 3 Burners

L2012200

L2012200

 

L2012200

L2012200

L20122000

 

 

 

(2)

(3)

 

(5)

(2)

(3)

 

 

 

 

 

 

 

 

 

 

 

Burner Tray, 4 Burners

 

 

L2012500

 

L2012500

L2012500

L2012500

 

 

 

 

(3)

 

(3)

(3)

(6)

82A

 

 

 

 

 

 

 

 

Gasket, Burner Tray, 3 Burner

S2012700

S2012700

 

S2012700

S2012700

S2012700

 

 

 

(2)

(3)

 

(5)

(2)

(3)

 

 

 

 

 

 

 

 

 

 

 

Gasket, Burner Tray, 4 Burner

 

 

S2012500

 

S2012500

S2012500

S2012500

 

 

 

 

(3)

 

(3)

(3)

(6)

 

 

 

 

 

 

 

 

 

 

Gasket Tape, RR, Base (43')

R2014500

R2014500

R2014500

R2014500

R2014500

R2014500

R2014500

 

 

 

 

 

 

 

 

 

 

Gasket Tape, Ft Air Chamber (63')

R2014600

R2014600

R2014600

R2014600

R2014600

R2014600

R2014600

 

 

 

 

 

 

 

 

 

COPPER BRUTE II (500 - 2000)

Page 59

Image 59
Contents Copper Brute Table of Contents Operating Instructions MaintenanceTrouble Shooting Replacement PartsModel Identification General InformationIntroduction Locating the Appliance WarrantyDimensions Dimensional Data Inches 91cm horizontally Intake Combustion Air Venting and Combustion AirCombustion Air Combustion Air From RoomCommon Venting Systems VentingVent Categories Category I VentCombustion Air and Vent Through Side Wall Side Wall Combustion Air Terminal Locating Vent & Combustion Air TerminalsCategory III Vent Side Wall Vent TerminalVertical Combustion Air Terminal Common Vent Test BoilersVent Terminals for Outdoor Units Vertical Vent Terminal61-91m Gas Supply and Piping4A.3 Water Flow Requirements Boiler Water Connections Copper Brute II Boiler4A.1 Heating System Piping Hot Supply Connections Boiler 4A.2 Cold Water Make-Up BoilerHydronic Piping Multiple Boilers, Primary Secondary System Hydronic Piping Multiple Boilers, Low Temperature System Hydronic Piping One Boiler, Multi-Temperature System Hydronic Piping Primary-Secondary, Reverse-Return Boiler CIRC. Pump Sized for Flow Through Boiler 4B.3 Water Flow Requirements Water Heater Water Connections Copper Brute II Water Heater4B.1 Water System Piping Water Heater 4B.2 Hot Water Supply Piping Water HeaterSupply 4B.5 Freeze Protection Water HeaterWater Heater Piping Multiple Heaters, One Tank Water Heater Piping Multiple Heaters, Multiple Tanks Electrical Connections Main PowerTemperature Control Field Wiring Panel Avertissement External Staging Control WiringCopper Brute II 500 750 Ladder Diagram Copper Brute II 1000 Ladder Diagram Copper Brute II 1250 2000 Ladder Diagram Copper Brute II 500 1000 Wiring Schematic Copper Brute II 1250 1500 Wiring Schematic Copper Brute II 1750 2000 Wiring Schematic Terminal designations are as indicated Field Wiring for Modes 1 Avertissement Filling the Boiler System Operating InstructionsSequence of Operation Parallel Piping Programming the Temperature ControlChoosing the Mode System Piping Primary Secondary PipingFor ALL Other Modes Hydronic Primary/Secondary Mode Mechanical aquastat in a domestic hot water storage tank Choosing the Mode for your ApplicationMode 5 Primary secondary piping with outdoor reset Differential Staging ModeAdvanced Topics Pump Operation Boiler Target TemperatureBoiler Minimum Boil MIN Boiler Maximum Boil MAXDedicated Domestic Hot Water Outdoor Reset OperationSetpoint Operation Typical Gas Train Configuration External Boiler Operation Operating the Burner and Set UpAdvanced Programming Mode Set Up for 0 to 2500 Feet AltitudeTo Restart the Copper Brute High Altitude Adjustment and Set UpShutting Down the Copper Brute Appliance Maintenance Component Description MaintenanceSystem Maintenance Ignitors Temperature ControlFlow Switch Ignition ControlsBradford White Corp Trouble Shooting Troubleshooting Copper Brute Controls Troubleshooting the Temperature ControlCopper Brute II 500 Troubleshooting Error Codes Parts List Replacement PartsSee Figures 35 Heat Exchanger Components Electrical Components Gas Train Components Burner Manifold Assy, 4 Burners, Left, LP For reference Internal Components Copper Brute II Hydronic Electrical Components H2214401F