Bradford-White Corp BWCV, BWCH, Copper Brute II Hydronic Boiler warranty Electrical Components

Page 57

Item

Description

Size

Size

Size

Size

Size

Size

Size

 

 

500

750

1000

1250

1500

1750

2000

 

Relief Valve, BWCV, 125 PSI

RA0001200

RA0001200

RA0001200

RA0001200

A0064400

A0064400

A0066400

50

 

 

 

 

 

 

 

 

Tee, Adapter, Outlet, Cast Iron

20130001

20130001

20130001

20130002

20130002

20130002

20130002

 

 

 

 

 

 

 

 

 

 

Tee, Adapter, Outlet, Bronze

20150301

20150301

20150301

20150301

20150301

20150301

20150303

51

 

 

 

 

 

 

 

 

Flow Switch

RE0013000

RE0013000

RE0013000

RE0013000

RE0013000

RE0013000

RE0013000

52

 

 

 

 

 

 

 

 

Gauge, Temperature/Pressure

RA0079000

RA0079000

RA0079000

RA0079000

RA0079000

RA0079000

RA0079000

54

 

 

 

 

 

 

 

 

Low Water Cutoff

R0021901

R0021901

R0021901

R0021901

R0021901

R0021901

R0021901

55

 

 

 

 

 

 

 

 

Pump Housing, Glass-lined, Cast Iron

R20607600

R20607600

R20607600

R20607600

R20607600

R20607600

R20607600

 

 

 

 

 

 

 

 

 

 

Pump Housing, Bronze

10483300

10483300

10483300

10483300

10483300

10483300

10483300

56

 

 

 

 

 

 

 

 

Gasket, Pump Adapter

S0024600

S0024600

S0024600

S0024600

S0024600

S0024600

S0024600

57

 

 

 

 

 

 

 

 

Pump Adapter, Glass-lined Cast Iron

10364200

10364200

10364200

10364200

10364200

10364200

10364200

 

 

 

 

 

 

 

 

 

 

Pump Adapter, Bronze

10364201

10364201

10364201

10364201

10364201

10364201

10364201

58

 

 

 

 

 

 

 

 

Baffle, Diffuser, Pump Inlet

10338400

10338400

10338400

10338400

10338400

10338400

10338400

59

 

 

 

 

 

 

 

 

Pressure Switch

RE0240900

RE0240900

RE0240900

RE0240900

RE0240900

RE0240900

RE0240900

 

 

(2)

(2)

(2)

(3)

(3)

(3)

(3)

60

 

 

 

 

 

 

 

 

Blower

A2111900

A2111900

A2111900

A2111900

A2111900

A2111900

A2111900

 

 

(1)

(1)

(1)

(2)

(2)

(2)

(2)

61

 

 

 

 

 

 

 

 

Weldment, Blower Mount

5C5300

5C5300

5C5300

5C5300

5C5300

5C5300

5C5300

 

 

(1)

(1)

(1)

(2)

(2)

(2)

(2)

62

 

 

 

 

 

 

 

 

Damper, Duct Assembly, Blower

 

 

 

15C5400

15C5400

15C5400

15C5400

 

 

 

 

 

(2)

(2)

(2)

(2)

 

 

 

 

 

 

 

 

 

 

Electrical Components

 

 

 

 

 

 

 

 

See Figure 36

 

 

 

 

 

 

 

64

 

 

 

 

 

 

 

 

Bracket, Control Panel Mounting

5C7103

5C7103

5C7103

5C7103

5C7103

5C7103

5C7103

65

 

 

 

 

 

 

 

 

Terminal Board, Field Wiring

E2307400

E2307401

E2307402

E2307403

E2307404

E2307405

E2307406

66

 

 

 

 

 

 

 

 

Ignition Control, Single Trial

E2107300

E2107300

E2107300

E2107300

E2107300

E2107300

E2107300

 

 

(1)

(1)

(2)

(2)

(2)

(2)

(2)

 

 

 

 

 

 

 

 

 

 

Igniltion Control, Three Trial

E2313900

E2313900

E2313900

E2313900

E2313900

E2313900

E2313900

 

 

(1)

(1)

(2)

(2)

(2)

(2)

(2)

67

 

 

 

 

 

 

 

 

Diagnostic Board

E2105500

E2105500

E2105500

E2105500

E2105500

E2105500

E2105500

68

 

 

 

 

 

 

 

 

Indicator Light Panel Board

E2105600

E2105600

E2105600

E2105600

E2105600

E2105600

E2105600

69

 

 

 

 

 

 

 

 

Temperature Control

E2106900

E2106900

E2106800

E2106800

E2106800

E2106800

E2106800

70

 

 

 

 

 

 

 

 

High Limit, Auto Reset, BWCH

RE0014400

RE0014400

RE0014400

RE0014400

RE0014400

RE0014400

RE0014400

 

 

 

 

 

 

 

 

 

 

High Limit, Auto Reset, BWCV, 210F Max.

E2217700

E2217700

E2217700

E2217700

E2217700

E2217700

E2217700

 

 

 

 

 

 

 

 

 

COPPER BRUTE II (500 - 2000)

Page 57

Image 57
Contents Copper Brute Table of Contents Trouble Shooting MaintenanceReplacement Parts Operating InstructionsGeneral Information IntroductionModel Identification Warranty DimensionsLocating the Appliance Dimensional Data Inches 91cm horizontally Combustion Air Venting and Combustion AirCombustion Air From Room Intake Combustion AirVent Categories VentingCategory I Vent Common Venting SystemsCombustion Air and Vent Through Side Wall Category III Vent Locating Vent & Combustion Air TerminalsSide Wall Vent Terminal Side Wall Combustion Air TerminalVent Terminals for Outdoor Units Common Vent Test BoilersVertical Vent Terminal Vertical Combustion Air Terminal61-91m Gas Supply and Piping4A.1 Heating System Piping Hot Supply Connections Boiler Water Connections Copper Brute II Boiler4A.2 Cold Water Make-Up Boiler 4A.3 Water Flow Requirements BoilerHydronic Piping Multiple Boilers, Primary Secondary System Hydronic Piping Multiple Boilers, Low Temperature System Hydronic Piping One Boiler, Multi-Temperature System Hydronic Piping Primary-Secondary, Reverse-Return Boiler CIRC. Pump Sized for Flow Through Boiler 4B.1 Water System Piping Water Heater Water Connections Copper Brute II Water Heater4B.2 Hot Water Supply Piping Water Heater 4B.3 Water Flow Requirements Water HeaterSupply 4B.5 Freeze Protection Water HeaterWater Heater Piping Multiple Heaters, One Tank Water Heater Piping Multiple Heaters, Multiple Tanks Main Power Temperature ControlElectrical Connections Field Wiring Panel Avertissement External Staging Control WiringCopper Brute II 500 750 Ladder Diagram Copper Brute II 1000 Ladder Diagram Copper Brute II 1250 2000 Ladder Diagram Copper Brute II 500 1000 Wiring Schematic Copper Brute II 1250 1500 Wiring Schematic Copper Brute II 1750 2000 Wiring Schematic Terminal designations are as indicated Field Wiring for Modes 1 Avertissement Operating Instructions Sequence of OperationFilling the Boiler System Choosing the Mode Programming the Temperature ControlSystem Piping Primary Secondary Piping Parallel PipingFor ALL Other Modes Hydronic Primary/Secondary Mode Mechanical aquastat in a domestic hot water storage tank Choosing the Mode for your ApplicationMode 5 Primary secondary piping with outdoor reset Staging Mode Advanced TopicsDifferential Boiler Minimum Boil MIN Boiler Target TemperatureBoiler Maximum Boil MAX Pump OperationOutdoor Reset Operation Setpoint OperationDedicated Domestic Hot Water Typical Gas Train Configuration Advanced Programming Mode Operating the Burner and Set UpSet Up for 0 to 2500 Feet Altitude External Boiler OperationHigh Altitude Adjustment and Set Up Shutting Down the Copper BruteTo Restart the Copper Brute Maintenance System MaintenanceAppliance Maintenance Component Description Flow Switch Temperature ControlIgnition Controls IgnitorsBradford White Corp Trouble Shooting Troubleshooting Copper Brute Controls Troubleshooting the Temperature ControlCopper Brute II 500 Troubleshooting Error Codes Parts List Replacement PartsSee Figures 35 Heat Exchanger Components Electrical Components Gas Train Components Burner Manifold Assy, 4 Burners, Left, LP For reference Internal Components Copper Brute II Hydronic Electrical Components H2214401F