A
B C
D
A. Front cover | C. Spring clip |
B. Blower mounting screws | D. Motor electrical plug |
Install In-line Blower System
NOTE: The blower motor housing can be mounted using 4 holes from either the outlet side or the inlet side of the blower.
Outlet Side:
AA
A
A
A. Mounting holes
Inlet Side:
A
A
A. Mounting holes
1.Position the
2.Drill 4 mounting pilot holes using a ³⁄₁₆" (0.48 cm) drill bit.
3.Attach the
4.If it is removed, reinstall the blower motor assembly and secure it with the screws previously removed.
5.If it is removed, reattach the motor electrical plug to the connector on the blower motor assembly.
Complete Preparation
1.Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall, do not damage electrical wiring or other hidden utilities.
2.Determine the location where the ¹⁄₂" (1.3 cm) wiring conduit will be routed through the ceiling or wall between the
3.Drill a 1¹⁄₄" (3.2 cm) hole at this location.
4.Locate the electrical terminal boxes in the
B
A
A. Electrical terminal box
B. Electrical knockout
5.Remove the electrical knockout from the
6.With the range hood mounted (see the “Install Range Hood” section), run the ¹⁄₂" (1.3 cm) wiring conduit between the in- line blower motor housing and the range hood. Pull enough ¹⁄₂" (1.3 cm) wiring conduit to allow for easy connection to the terminal boxes in the
7.Run the six 18 AWG wires through the ¹⁄₂" (1.3 cm) wiring conduit and conduit connectors and into the terminal boxes on the
8.Install the conduit connectors and conduit to the
9.Connect the vent system to the range hood and
Make Electrical Connections for In-Line
Blower Motor System
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Electrical Connection Inside In-line Blower System
1.Disconnect power.
2.Connect the wires from the wiring conduit to the wires from the motor electrical plug cable inside the