Make Electrical Power Supply Connection to
Range Hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Locate terminal box on top of the range hood.
A
B
A. Knockout in back of terminal box
B. Top of terminal box
| E |
A |
|
B |
|
C |
|
D | F |
A. White wires | D. Green, bare or yellow/green wires |
B. Black wires | E. Home power supply |
C. UL listed wire | F. UL listed or CSA approved ¹⁄₂" (1.3 cm) |
connectors | strain relief |
3.Use UL listed wire connectors and connect black wires (B) together.
4.Use UL listed wire connectors and connect white wires (A) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
NOTE: When using an
5.Connect green (or bare) ground wire from home power supply to the green/yellow ground wire (D) in terminal box using UL listed wire connectors.
6.Install terminal box cover.
7.Check that all light bulbs are secure in their sockets.
8.Reconnect power.
Install Chimney Covers
1.Install damper on top of the exhaust opening. Check that the damper opens freely.
2.Connect the vent system and seal all connections with clamps.
Install Upper Chimney Cover
1.Slightly spread the sides of the cover apart and hook them behind the chimney mounting brackets.
2.Attach the cover to the brackets with 2 flat head screws.
3.Securely tighten screws.
A
A
A. 2 flat head screws
Install Lower Chimney Cover
1.Slightly spread the sides of the cover apart and hook them behind the upper chimney.
13