KitchenAid LI3ZBC/W10331009C Install Range Hood Internal Blower Motor, Dual Blower Motor Assembly

Page 9

Five 6 mm nuts are required for the dual motor system. Clip nuts into the small square notches, one located in the front of the square vent opening and the other four located at the left and right ends of the square vent opening.

A

A

A

B

A. Clip nut (6 mm) locations for dual motor assembly (quantity 5) B. Clip nut (6 mm) locations for single motor assembly (quantity 2)

5.Mount range hood. See the “Install Range Hood” section.

Install Range Hood Internal Blower Motor

1.Install the range hood blower motor assembly inside the range hood canopy with the wiring connection to the left for the single motor system and to the front or top for the dual motor system.

Single Blower Motor Assembly

A

A. Wiring connection

Dual Blower Motor Assembly

A

A. Wiring connection

2.Slide the left mounting plate flange under the motor mounting bracket.

AB

A.Motor mounting bracket

B.Mounting plate left flange

3.Run the power supply wires and connector from the range hood through the hole in the right end of the motor mounting plate.

A

B

A. Motor mounting plate hole

B. Power supply wires and connector

9

Image 9
Contents COMMERCIAL-STYLE WALL-MOUNT Canopy Range Hood Table of Contents Range Hood SafetyTable DES Matières Important Safety Instructions Installation Requirements Tools and PartsLocation Requirements Cold Weather Installations Installation DimensionsVenting Requirements For the Most Efficient and Quiet OperationElectrical Requirements Typical In-line Blower Motor System Venting InstallationsCalculating Vent System Length Example Vent SystemRange Hood Mounting Screws Installation Installation InstructionsChimney Support Bracket Installation Prepare LocationInstall Range Hood Install Range Hood Internal Blower MotorPrepare the Internal Blower System Install Range Hood Internal Blower Motor Single Blower Motor AssemblyDual Blower Motor Assembly Install Range Hood In-Line External Type Blower Motor Prepare for Mounting the In-Line Blower SystemPrepare the In-line Blower System Make Electrical Connections for In-Line Blower Motor System Install In-line Blower System Outlet SideInlet Side Electrical Connection Inside In-line Blower SystemTogether Complete Preparation in the Prepare Location sectionInstall Upper Chimney Cover Install Chimney CoversInstall Lower Chimney Cover Range HoodComplete Installation and Check Operation Range Hood USERange Hood Controls Range Hood Care CleaningMotor Resistance Ohms Accessories Assistance or ServiceU.S.A CanadaThis limited warranty does not cover Kitchenaid Ventilation WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreImportantes Instructions DE Sécurité Exigences Dinstallation Exigences d’emplacementOutils et pièces Installations pour régions à climat froid Dimensions à respecter lors de l’installationExigences concernant lévacuation Air dappointExemple de système de décharge Spécifications électriquesCalcul de la longueur effective du circuit dévacuation Décharge à travers le toit Décharge à travers le murPréparation de l’emplacement Instructions D’INSTALLATIONInstallation des vis de montage de la hotte Installation de la bride de support de la cheminéeInstallation du moteur du ventilateur interne De la hotte Installation de la hotteAchever la préparation Préparer le système de ventilation interneInstallation du moteur du ventilateur interne de la hotte Ensemble à un seul moteur-ventilateurEnsemble à deux moteurs-ventilateurs Avertissement Installation du système de ventilation en ligne Côté sortieCôté entrée Une fois la hotte montée voir la section Instructions Homologation UL Installation du cache-cheminéeInstallation de la section supérieure du cache-cheminée Achever linstallation et vérifier le FonctionnementInstallation de la section inférieure du cache-cheminée Utilisation DE LA HotteCommandes de la hotte de cuisinière Nettoyage Entretien DE LA HotteRésistance du moteur ohms Assistance OU Service AccessoiresAu Canada Garantie DU Système DE Ventilation Kitchenaid La présente garantie limitée ne couvre pasW10331009C