KitchenAid LI3ZBC/W10331009C Complete Preparation in the Prepare Location section, Together

Page 12

B

A

C

D

E

F

G

H

I

Electrical Connection Inside Range Hood Between In-line Blower System and Range Hood

1.

With the range hood mounted (see the “Install Range Hood”

 

section), locate the wiring cable connector inside the range

 

hood.

2.

Connect the 6-wire connector assembly supplied with the

 

in-line blower motor system to the mating cable connector

 

from the range hood.

3.

Locate the terminal box inside the range hood and install a

 

¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see

 

“Complete Preparation” in the “Prepare Location” section).

A. UL listed or CSA approved ¹⁄₂" F. Blue wires

(1.3 cm) wiring conduit

G. Gray wires

B. UL listed wire connectors

H. Green (or yellow/green)

C. Black wires

and green/yellow wires

D. White wires

I. Motor electrical plug cable

E. Red wires

 

3.

Use UL listed wire connectors and connect the black wires

 

(C) together.

4.

Use UL listed wire connectors and connect the white wires

 

(D) together.

5.

Use UL listed wire connectors and connect the red wires (E)

 

together.

6.

Use UL listed wire connectors and connect the blue wires (F)

 

together.

4.

Run the wire ends from the 6-wire connector assembly

 

through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire

 

length to make the wiring connections. Tighten the strain

 

relief screws.

5.

Connect the wires from the 6-wire connector assembly to the

 

wires from the wiring conduit inside the range hood terminal

 

box.

6.

Connect the same color wires to each other (black to black,

 

white to white, etc.) using UL listed wire connectors.

 

NOTE: Connect the green (or green/yellow) ground wire from

 

the wiring conduit to the green (or bare) ground wire from the

 

home power supply using UL listed wire connectors (see the

 

“Make Electrical Power Supply Connection to Range Hood”

 

section).

7. Use UL listed wire connectors and connect the gray wires (G)

together.

WARNING

Electrical Shock Hazard

B

A

C

D

E

F

G

H

Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

8.Connect the green (or yellow/green) ground wire to the green/yellow ground wire (H) in the terminal box using UL listed wire connectors.

9.Reinstall the in-line blower terminal box cover and screw.

10.Reinstall the front cover of the in-line blower housing and secure it with 10 mounting screws.

 

I

A. UL listed or CSA approved

E. Red wires

¹⁄₂" (1.3 cm) wiring conduit

F. Blue wires

B. UL listed wire connectors

G. Gray wires

C. Black wires

H. Green (or green/yellow) wire

D. White wires

I. 6-wire connector assembly

7.Go to “Make Electrical Power Supply Connection to Range Hood” section.

12

Image 12
Contents COMMERCIAL-STYLE WALL-MOUNT Canopy Range Hood Table of Contents Range Hood SafetyTable DES Matières Important Safety Instructions Installation Requirements Tools and PartsLocation Requirements Installation Dimensions Cold Weather InstallationsVenting Requirements For the Most Efficient and Quiet OperationTypical In-line Blower Motor System Venting Installations Electrical RequirementsCalculating Vent System Length Example Vent SystemInstallation Instructions Range Hood Mounting Screws InstallationChimney Support Bracket Installation Prepare LocationInstall Range Hood Install Range Hood Internal Blower MotorPrepare the Internal Blower System Install Range Hood Internal Blower Motor Single Blower Motor AssemblyDual Blower Motor Assembly Install Range Hood In-Line External Type Blower Motor Prepare for Mounting the In-Line Blower SystemPrepare the In-line Blower System Install In-line Blower System Outlet Side Make Electrical Connections for In-Line Blower Motor SystemInlet Side Electrical Connection Inside In-line Blower SystemComplete Preparation in the Prepare Location section TogetherInstall Chimney Covers Install Upper Chimney CoverInstall Lower Chimney Cover Range HoodComplete Installation and Check Operation Range Hood USERange Hood Controls Cleaning Range Hood CareMotor Resistance Ohms Assistance or Service AccessoriesU.S.A CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences Dinstallation Exigences d’emplacementOutils et pièces Dimensions à respecter lors de l’installation Installations pour régions à climat froidExigences concernant lévacuation Air dappointSpécifications électriques Exemple de système de déchargeCalcul de la longueur effective du circuit dévacuation Décharge à travers le toit Décharge à travers le murInstructions D’INSTALLATION Préparation de l’emplacementInstallation des vis de montage de la hotte Installation de la bride de support de la cheminéeInstallation de la hotte Installation du moteur du ventilateur interne De la hotteAchever la préparation Préparer le système de ventilation interneInstallation du moteur du ventilateur interne de la hotte Ensemble à un seul moteur-ventilateurEnsemble à deux moteurs-ventilateurs Avertissement Installation du système de ventilation en ligne Côté sortieCôté entrée Une fois la hotte montée voir la section Instructions Installation du cache-cheminée Homologation ULAchever linstallation et vérifier le Fonctionnement Installation de la section supérieure du cache-cheminéeInstallation de la section inférieure du cache-cheminée Utilisation DE LA HotteCommandes de la hotte de cuisinière Entretien DE LA Hotte NettoyageRésistance du moteur ohms Assistance OU Service AccessoiresAu Canada Garantie DU Système DE Ventilation Kitchenaid La présente garantie limitée ne couvre pasW10331009C