KitchenAid LI3ZBC/W10331009C Range Hood USE, Complete Installation and Check Operation

Page 14

2.Secure the lower chimney covers to the range hood canopy using 4 - 4.2 x 8 mm screws.

A. Lower chimney covers

B. Range hood canopy

C. 4 - 4.2 x 8 mm screws

A

G

F

A. Halogen lights

B. Blower control switches C. Halogen light switch D. Heat lamp switch

B

C

D

E

E. Heat lamps F. Grease filter

G. Grease filter handles

Complete Installation and Check Operation

1.Install grease filters. See “Range Hood Care” section.

2.Check operation of the range hood blower and lights. See “Range Hood Use” section.

3.If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power supply and check that the wiring is correct.

NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section.

RANGE HOOD USE

The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the range hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen.

The range hood controls are located on the underside of the range hood.

ABC

A. Light control

B. Blower control

C. Fan speed control

Range Hood Controls

Operating the light

1.Move the light switch to the “1” position to turn range hood light to night light setting.

2.Move the light switch to the “2” position to turn range hood light to full light setting.

3.Move the light switch to the “Off” position to turn range hood light OFF.

Operating the fan

1.Move the fan switch to the “On” position to turn the fan ON. The fan will begin operating at the speed set on the fan speed switch.

2.Move the fan switch to the “Off” position to turn the fan OFF.

Auto On Fan

The range hood is equipped with a sensor to automatically turn on the fan when excessive heat is detected in the control area. When the fan switch is in the “Off” position, this sensor will turn the fan to high speed when necessary. When the heat decreases, the fan will turn off.

When the fan switch is in the “On” position, the heat sensor is not active and the range hood functions normally.

Adjusting the fan

The fan has 3 speed controls. Move the fan speed switch to “1” position for low speed, “2” position for medium speed, or “3” position for high speed.

Thermal Protector

The range hood is equipped with a thermal protector to avoid overheating conditions. If the range hood shuts off while in use, move fan slider switch to Off to turn off the range hood. Wait approximately 60 minutes, then move slider to On to restart the range hood.

Operating the heat lamp

The heat lamps are designed to keep food warm prior to serving. The cooktop surface is too far away from the heat lamp to be used as a shelf.

For best results, install a metal shelf to hold the food closer to the lamps. The optimum distance between the shelf and the range hood is 12" (30.5 cm) to 15" (38.1 cm).

14

Image 14
Contents COMMERCIAL-STYLE WALL-MOUNT Canopy Range Hood Table DES Matières Table of ContentsRange Hood Safety Important Safety Instructions Location Requirements Installation RequirementsTools and Parts Venting Requirements Installation DimensionsCold Weather Installations For the Most Efficient and Quiet OperationCalculating Vent System Length Typical In-line Blower Motor System Venting InstallationsElectrical Requirements Example Vent SystemChimney Support Bracket Installation Installation InstructionsRange Hood Mounting Screws Installation Prepare LocationPrepare the Internal Blower System Install Range HoodInstall Range Hood Internal Blower Motor Dual Blower Motor Assembly Install Range Hood Internal Blower MotorSingle Blower Motor Assembly Prepare the In-line Blower System Install Range Hood In-Line External Type Blower MotorPrepare for Mounting the In-Line Blower System Inlet Side Install In-line Blower System Outlet SideMake Electrical Connections for In-Line Blower Motor System Electrical Connection Inside In-line Blower SystemComplete Preparation in the Prepare Location section TogetherInstall Lower Chimney Cover Install Chimney CoversInstall Upper Chimney Cover Range HoodRange Hood Controls Complete Installation and Check OperationRange Hood USE Cleaning Range Hood CareMotor Resistance Ohms U.S.A Assistance or ServiceAccessories CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences d’emplacement Exigences concernant lévacuation Dimensions à respecter lors de l’installationInstallations pour régions à climat froid Air dappointCalcul de la longueur effective du circuit dévacuation Spécifications électriquesExemple de système de décharge Décharge à travers le toit Décharge à travers le murInstallation des vis de montage de la hotte Instructions D’INSTALLATIONPréparation de l’emplacement Installation de la bride de support de la cheminéeAchever la préparation Installation de la hotteInstallation du moteur du ventilateur interne De la hotte Préparer le système de ventilation interneEnsemble à deux moteurs-ventilateurs Installation du moteur du ventilateur interne de la hotteEnsemble à un seul moteur-ventilateur Avertissement Côté entrée Installation du système de ventilation en ligneCôté sortie Une fois la hotte montée voir la section Instructions Installation du cache-cheminée Homologation ULInstallation de la section inférieure du cache-cheminée Achever linstallation et vérifier le FonctionnementInstallation de la section supérieure du cache-cheminée Utilisation DE LA HotteCommandes de la hotte de cuisinière Entretien DE LA Hotte NettoyageRésistance du moteur ohms Au Canada Assistance OU ServiceAccessoires W10331009C Garantie DU Système DE Ventilation KitchenaidLa présente garantie limitée ne couvre pas