Buttons and LED’s

Buttons and LED’s

Manual – This button is used to toggle between auto and manual filtration mode. A corresponding LED is lit when in Manual mode. When pressed, a message will be sent to all vats, indicating the mode has changed.

The following buttons are inoperable in auto mode:

Select - This button is used to scroll through available vats, choosing one to be manually filtered.

Drain – This button is used to open and close the drain on the vat indicated on the display. It’s embedded LED indicates the following activity:

Blink: Actuator is moving or awaiting a response from the AIF board.

Constant Illumination: Drain open.

No Illumination: Drain closed.

Return – This button is used to open and close the return valve on the vat indicated on the display. When pressed and held, it also turns on and off the pump. It’s embedded LED indicates the following activity:

Blink: Actuator is moving or awaiting a response from the AIF board.

Constant Illumination: Return valve open.

No Illumination: Return valve closed.

1.11.1 Manually Draining, Refilling or Filtering using the MIB board

Press the manual/auto switch to set to manual. The LED on the manual key will illuminate and a vat number is displayed (see Figure 8).

Figure 8

Press the vat selector switch to change vats (see

Figure 9).

Figure 9

Pressing the drain or the return switch illuminates and activates the drain or return valve for the vat indicated. Pressing and holding the return switch while the return is open activates the filter motor and pump (see Figure 10).

Figure 10

Pressing the manual/auto switch will return to automatic mode.

1-17

Image 24
Contents SERVICE AND PARTS MANUAL FRYMASTER BIELA14 SERIES GEN LOV ELECTRIC FRYERemail: service@frymaster.com 8196446NOTICE NOTICENOTICE DANGERDo not use water jets to clean this equipment DANGERDANGERi DANGERA.WARRANTY PROVISIONS - FRYERS B.WARRANTY PROVISIONS - FRYPOTSD.WARRANTY EXCLUSIONS C.PARTS RETURNELECTRICAL POWER SPECIFICATIONS TABLE OF CONTENTS BIELA14 SERIES GEN II LOV ELECTRIC FRYERSCHAPTER 1: Service Procedures TABLE OF CONTENTS cont CHAPTER 2: Parts ListBIELA14 SERIES GEN II LOV ELECTRIC FRYERS CHAPTER 1: SERVICE PROCEDURES BIELA14 SERIES GEN II LOV ELECTRIC FRYERS1.1 General 1.2 Replacing a Computer3.Remove the two screws from the upper corners of the computer and allow the computer to swing down 1.4 Replacing a High-LimitThermostat DANGER1.5 Replacing a Temperature Probe 4.Locate the red or yellow and white wires of the temperature probe to be replaced. Note where the leads are connected prior to removing them from the connector. Unplug the 12-pinconnector C-6and using a pin-pusherpush the pins of the temperature probe out of the connector 1.6Replacing a Heating Element Full vat element wire routing Dual vat element wire routingElement grounding and wire routing 1.7Replacing Contactor Box Components 1.8 Replacing a Frypot DANGER17.Disconnect the oil return flexlines malfunction DANGER 1.9.3 Replacing the Transformer or Filter Relay 1.10 ATO Automatic Top-offService Procedures 1.10.1 ATO Automatic Top-offTroubleshootingProblem Probable Causes Problem SERVICE Probable Causes Corrective ActionWire 1.10.4 Replacing the ATO Pump Reset SwitchDrain Switch SwitchButtons and LED’s The following buttons are inoperable in auto modeConstant Illumination: Drain open No Illumination: Drain closed1.11.2 MIB Manual Interface Board Troubleshooting ProblemProbable Causes Corrective ActionProblem Probable CausesCorrective Action 1-19Connector Resetting DISPLAYEXPLANATION Drain1.11.7 Control Power Reset Switch 1.11.6 Replacing the MIB Board1.12RTI Service Issues 1.12.1 RTI MIB Tests TroubleshootingWaste full signal AC voltage measurements1.12.2 RTI LOV Wiring 1.12.4 RTI LOV TEST QUICK REFERENCE DISPOSE TO WASTE, REFILL VAT FROM BULKDISPOSE TO WASTE FILL VAT FROM BULKFILL JUG FROM BULK Problem 1.13.1 AIF TroubleshootingCorrective Action Probable CausesWire 1.13.4 Replacing a Linear Actuator 1.13.5 Replacing a Rotary Actuator ProblemRECOVERY FAULTProbable Causes ProblemMISCONFIGURED Corrective ActionProblem Probable CausesCorrective Action PASSWORDS 1.14.2 M3000 Useful CodesProblem •0469 – Reset FILTER STAT DATA1.14.3 Service Required Errors ERROR MESSAGEEXPLANATION 1-341.14.4 Error Log Codes ERROR MESSAGEEXPLANATION 1-351.14.5 Tech Mode 1.14.6 M3000 Filter Error Flowchart NORMAL ERRORSYSTEM ERROR FIXED? YES OPERATION RESUMES1.14.7 M3000 Menu Summary Tree Adding New Menu ItemsStoring Menu Items in Product Buttons Draining, Refilling, and Disposing of Oil1.14.8 M3000 Board Pin Positions and Harnesses 1.15Loading and Updating Software Procedures SETUP COMPLETE is displayedUNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 24.FILTER NOW YES/NO is displayed1.16 BIELA14 Series LOV Data Network Flowchart 1.17 Interface Board Diagnostic Chart Diagnostic LED LegendPN 826-2260 1-421.18 Probe Resistance Chart Probe Resistance ChartOHMS OHMS1.19 Wiring Diagrams 1.19.1 Component Wiring Domestic1.19.2 Component Wiring CE 1.19.3 Component Wiring CSA 1.19.4 Component Wiring Australia 1.19.5 Contactor Box – Delta Configuration 1.19.6 Contactor Box - WYE Configuration Page Page Page Page Page CHAPTER 2 PARTS LIST AccessoriesITEM PART #ITEM PART #COMPONENT Not illustrated2.3Drain System Components 2.3.1 Drain Tube Sections and Associated PartsPART# ITEM2.3.2.2 Rotary Actuator Drain Valves ITEMPART # COMPONENTPage 2.4.1 Component Boxes cont ITEM PART #boxes COMPONENT2.4.2Contactor Boxes PART # COMPONENT106-8658 2.4.3Heating Element Assemblies and Associated Parts 2.4.3.1 Element Assemblies and Hardware 2.4.3.1 Element Assemblies and Hardware cont WYE unitsITEM PART # COMPONENT2.4.3.2 Element Tube Assemblies FULL-VATELEMENT ASSEMBLYDUAL-VATELEMENT ASSEMBLY 2.4.3.2 Element Tube Assemblies contd 2.4.4Computers ITEM2.4.5Wiring COMPONENT Contactor Box Harness Assembly Dual VatPART # ITEM PART #106-8744 14/17 kW Mechanical ContactorITEM PART #2.4.5.5 Main Wiring Harnesses Filter Pump C2 to Component Box Wiring Harness PART #COMPONENT Full Vat Control Harness J4 to J2 Standard2.4.5.8 M3000, MIB, AIF and ATO Wiring Harnesses Reset Switch 4-5Battery onlyonly ITEMPage 2.5.1 Filtration Components contCOMPONENT ITEM2.5.2.2 Manual Interface Board Assembly ITEM PART #COMPONENT ITEM PART #2.5.2.3 AIF Board Assembly 2.5.2.4 LOV PCB/Computer Board MatrixITEM PART # COMPONENTSee Page 2-5for Drain Valve Assemblies PART #COMPONENT 2.6.2 Frypots with Rotary Actuators ITEMPART # COMPONENT2.7 Oil Return Manifolds 2.8 Return Valves and Associated PartsITEM PART #2.9.2 JIB Cap and Pick Up Assembly 2.8.2 Return Valve Rotary Actuators2.9Auto Top Off Components 2.9.1 JIB Basket PART #2.9.2 JIB Cap and Pick Up Assembly cont 2.9.3 Automatic Top Off Board Assemblyshipping ITEM2.9.4ATO Pump Assembly Domestic UnitsInternational Units ITEMITEM PART #COMPONENT 108-30412.10RTI 2.10.1 RTI Manifold and Accessories 2.10.1 RTI Manifold and Accessories cont ITEMPART # COMPONENT2.10.2RTI Dispose Waste Valve 2.10.3 RTI Test BoxMicroswitch, Gold Sealed Valve, ½” Ball Cover, DV Safety Switch Cover, DV Safety SwitchConnectors and Tools 2.12Fasteners ITEMPART # COMPONENTTHIS PAGE INTENTIONALLY LEFT BLANK SERVICE HOTLINE FAX PartsTech Support 1-800-551-8633