1.14.3 Service Required Errors

A SERVICE REQUIRED error alternating with YES displays on the computer. After YES is pressed the alarm is silenced. The computer displays an error message from the list below three times with the location of the error. Then the computer displays SYSTEM ERROR FIXED? YES/NO. If yes is chosen, enter code 1111. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error until issue is fixed.

Pressing the MIB reset button during any filter function will generate a “SERVICE REQUIRED” error.

This is a list of the service required errors and causes.

ERROR MESSAGE

EXPLANATION

PUMP NOT FILLING

Oil not returning to

vat quickly. Possible

 

problems: dirty pad, bad or missing O-rings,

 

tripped or defective filter pump, actuators or

 

linkage.

 

DRAIN VALVE NOT OPEN

Drain valve failed to open; the valve’s

 

position is unknown.

 

DRAIN VALVE NOT CLOSED

Drain valve failed to close; the valve’s

 

position is unknown.

 

RETURN VALVE NOT OPEN

Return valve failed to open; the valve’s

 

position is unknown.

 

RETURN VALVE NOT CLOSED

Return valve failed to close; the valve’s

 

position is unknown.

 

MIB BOARD

Problem with CAN communications; Check

 

for loose CAN connections between

 

computer and MIB board. MIB board failure

AIF BOARD

MIB detects AIF missing; AIF board failure

ATO BOARD

MIB detects ATO board connection lost;

 

ATO board failure

 

HIGH LIMIT FAILURE

High limit circuit has an issue

AIF PROBE

AIF RTD reading out of range

ATO PROBE

ATO RTD reading out of range

TEMP PROBE FAILURE

TEMP Probe reading out of range

MIB SOFTWARE

Internal MIB software error

INVALID CODE LOCATION

SD card removed during update

MISCONFIGURED ENERGY TYPE

Energy type in fryer setup is incorrect. (ie.

 

Set proper energy type gas or electric)

 

Press 1234 to enter setup to properly

 

configure fryer.

 

RTC INVALID DATE

The date is invalid.

Press 1234 to enter

 

setup to properly configure fryer and set

 

proper date.

 

1-34

Image 41
Contents FRYMASTER BIELA14 SERIES GEN LOV ELECTRIC FRYER SERVICE AND PARTS MANUALemail: service@frymaster.com 8196446NOTICE NOTICENOTICE DANGERDANGER Do not use water jets to clean this equipmentDANGERi DANGERB.WARRANTY PROVISIONS - FRYPOTS A.WARRANTY PROVISIONS - FRYERSD.WARRANTY EXCLUSIONS C.PARTS RETURNELECTRICAL POWER SPECIFICATIONS CHAPTER 1: Service Procedures TABLE OF CONTENTSBIELA14 SERIES GEN II LOV ELECTRIC FRYERS BIELA14 SERIES GEN II LOV ELECTRIC FRYERS TABLE OF CONTENTS contCHAPTER 2: Parts List BIELA14 SERIES GEN II LOV ELECTRIC FRYERS CHAPTER 1: SERVICE PROCEDURES1.1 General 1.2 Replacing a Computer3.Remove the two screws from the upper corners of the computer and allow the computer to swing down 1.5 Replacing a Temperature Probe 1.4 Replacing a High-LimitThermostatDANGER 4.Locate the red or yellow and white wires of the temperature probe to be replaced. Note where the leads are connected prior to removing them from the connector. Unplug the 12-pinconnector C-6and using a pin-pusherpush the pins of the temperature probe out of the connector 1.6Replacing a Heating Element Element grounding and wire routing Full vat element wire routingDual vat element wire routing 1.7Replacing Contactor Box Components DANGER 1.8 Replacing a Frypot17.Disconnect the oil return flexlines malfunction DANGER 1.9.3 Replacing the Transformer or Filter Relay 1.10.1 ATO Automatic Top-offTroubleshooting 1.10 ATO Automatic Top-offService ProceduresProblem Probable CausesSERVICE ProblemProbable Causes Corrective ActionWire Reset Switch 1.10.4 Replacing the ATO PumpDrain Switch SwitchThe following buttons are inoperable in auto mode Buttons and LED’sConstant Illumination: Drain open No Illumination: Drain closedProblem 1.11.2 MIB Manual Interface Board TroubleshootingProbable Causes Corrective ActionProbable Causes ProblemCorrective Action 1-19Connector DISPLAY ResettingEXPLANATION Drain1.11.6 Replacing the MIB Board 1.11.7 Control Power Reset SwitchTroubleshooting 1.12RTI Service Issues 1.12.1 RTI MIB TestsWaste full signal AC voltage measurements1.12.2 RTI LOV Wiring DISPOSE TO WASTE, REFILL VAT FROM BULK 1.12.4 RTI LOV TEST QUICK REFERENCEDISPOSE TO WASTE FILL VAT FROM BULKFILL JUG FROM BULK 1.13.1 AIF Troubleshooting ProblemCorrective Action Probable CausesWire 1.13.4 Replacing a Linear Actuator Problem 1.13.5 Replacing a Rotary ActuatorRECOVERY FAULT Problem Probable Causes MISCONFIGURED Corrective ActionCorrective Action ProblemProbable Causes 1.14.2 M3000 Useful Codes PASSWORDSProblem •0469 – Reset FILTER STAT DATAERROR MESSAGE 1.14.3 Service Required ErrorsEXPLANATION 1-34ERROR MESSAGE 1.14.4 Error Log CodesEXPLANATION 1-351.14.5 Tech Mode ERROR 1.14.6 M3000 Filter Error Flowchart NORMALSYSTEM ERROR FIXED? YES OPERATION RESUMESAdding New Menu Items 1.14.7 M3000 Menu Summary TreeStoring Menu Items in Product Buttons Draining, Refilling, and Disposing of Oil1.14.8 M3000 Board Pin Positions and Harnesses SETUP COMPLETE is displayed 1.15Loading and Updating Software ProceduresUNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 24.FILTER NOW YES/NO is displayed1.16 BIELA14 Series LOV Data Network Flowchart Diagnostic LED Legend 1.17 Interface Board Diagnostic ChartPN 826-2260 1-42Probe Resistance Chart 1.18 Probe Resistance ChartOHMS OHMS1.19.1 Component Wiring Domestic 1.19 Wiring Diagrams1.19.2 Component Wiring CE 1.19.3 Component Wiring CSA 1.19.4 Component Wiring Australia 1.19.5 Contactor Box – Delta Configuration 1.19.6 Contactor Box - WYE Configuration Page Page Page Page Page Accessories CHAPTER 2 PARTS LISTITEM PART #PART # ITEMCOMPONENT Not illustrated2.3.1 Drain Tube Sections and Associated Parts 2.3Drain System ComponentsPART# ITEMITEM 2.3.2.2 Rotary Actuator Drain ValvesPART # COMPONENTPage ITEM PART # 2.4.1 Component Boxes contboxes COMPONENT2.4.2Contactor Boxes 106-8658 PART #COMPONENT 2.4.3Heating Element Assemblies and Associated Parts 2.4.3.1 Element Assemblies and Hardware WYE units 2.4.3.1 Element Assemblies and Hardware contITEM PART # COMPONENTDUAL-VATELEMENT ASSEMBLY 2.4.3.2 Element Tube AssembliesFULL-VATELEMENT ASSEMBLY 2.4.4 2.4.3.2 Element Tube Assemblies contdComputers ITEMCOMPONENT Contactor Box Harness Assembly Dual Vat 2.4.5WiringPART # ITEM PART #14/17 kW Mechanical Contactor 106-8744ITEM PART #2.4.5.5 Main Wiring Harnesses PART # Filter Pump C2 to Component Box Wiring HarnessCOMPONENT Full Vat Control Harness J4 to J2 StandardReset Switch 4-5Battery only 2.4.5.8 M3000, MIB, AIF and ATO Wiring Harnessesonly ITEMPage Filtration Components cont 2.5.1COMPONENT ITEMITEM PART # 2.5.2.2 Manual Interface Board AssemblyCOMPONENT ITEM PART #2.5.2.4 LOV PCB/Computer Board Matrix 2.5.2.3 AIF Board AssemblyITEM PART # COMPONENTCOMPONENT See Page 2-5for Drain Valve AssembliesPART # ITEM 2.6.2 Frypots with Rotary ActuatorsPART # COMPONENT2.8 Return Valves and Associated Parts 2.7 Oil Return ManifoldsITEM PART #2.8.2 Return Valve Rotary Actuators 2.9.2 JIB Cap and Pick Up Assembly2.9Auto Top Off Components 2.9.1 JIB Basket PART #2.9.3 Automatic Top Off Board Assembly 2.9.2 JIB Cap and Pick Up Assembly contshipping ITEMDomestic Units 2.9.4ATO Pump AssemblyInternational Units ITEMPART # ITEMCOMPONENT 108-30412.10RTI 2.10.1 RTI Manifold and Accessories ITEM 2.10.1 RTI Manifold and Accessories contPART # COMPONENT2.10.3 RTI Test Box 2.10.2RTI Dispose Waste ValveMicroswitch, Gold Sealed Valve, ½” Ball Cover, DV Safety Switch Cover, DV Safety SwitchConnectors and Tools ITEM 2.12FastenersPART # COMPONENTTHIS PAGE INTENTIONALLY LEFT BLANK FAX Parts SERVICE HOTLINETech Support 1-800-551-8633