![Probable Causes](/images/new-backgrounds/59920/5992075x1.webp)
Problem | Probable Causes | |
M3000 display shows |
| |
ENERGY | Wrong energy type selected in setup. | |
MISCONFIGURED |
| |
M3000 display shows |
| |
EXCEPTION | An error has occurred. | |
ERROR with the | ||
description on the right. |
| |
M3000 displays |
| |
SERVICE | An error has occurred. | |
REQUIRED followed |
| |
by the error. |
| |
|
| |
M3000 display is in |
| |
wrong temperature | Incorrect display option programmed. | |
scale (Fahrenheit or | ||
| ||
Celsius). |
| |
M3000 displays | Filter error has occurred, filter pad | |
clogged, 24 hour filter pad change prompt | ||
CHANGE FILTER | ||
PAD. | has occurred or change filter pad was | |
ignored on a prior prompt. | ||
| ||
|
| |
M3000 display shows | A. Filter pan is not fully inserted into fryer. | |
INSERT pan. | B. Missing filter pan magnet. | |
| C. Defective filter pan switch. | |
|
| |
M3000 display shows | Frypot temperature is more than 410ºF | |
(210ºC) or, in CE countries, 395ºF | ||
(202ºC). | ||
| ||
M3000 display shows | Computer in | |
|
| |
M3000 display shows |
| |
low temp | Frypot temperature is between 180°F | |
alternating with MLT- | (82°C). | |
CYCL. |
| |
|
| |
M3000 display shows | Defective SD Card | |
ERROR RM SDCRD |
Corrective Action
Press 1234 to enter setup and set energy type for electric.
Press 1234 to enter setup and reconfigure the computer.
Press YES to silence alarm. The error is displayed three times. See list of issues in section 1.14.3. Fix issue. The computer displays SYSTEM ERROR FIXED? YES/NO. Press YES. Computer displays ENTER CODE. Enter 1111 to clear error code. Pressing NO will allow the fryer to cook but the error will be redisplayed every 15 minutes.
See section 1.14.2 on page
Change the filter pad and ensure the filter pan has been removed from the fryer for a minimum of 30 seconds.
Do NOT ignore CHANGE FILTER PAD prompts.
A.Pull filter pan out and fully reinsert into fryer.
B.Ensure the filter pan magnet is in place and if missing replace.
C.If the filter pan magnet is fully against the switch and computer continues to display INSERT pan, switch is
possibly defective.
This in an indication of a malfunction in the temperature control circuitry, including a failure of the
This is displayed only during a test of the
This display is normal when the fryer is first turned on while in the melt cycle mode. To bypass the melt cycle press and hold either #1 or #2 cook button under the LCD display until a chirp is heard. The computer displays EXIT MELT alternating with YES NO. Press the #1 YES button to exit melt. If the display continues, the fryer is not heating.
Replace card with another card.