Frymaster BIELA14 manual 1.14.6 M3000 Filter Error Flowchart NORMAL, Operation Resumes, System

Page 44
1.14.6 M3000 Filter Error Flowchart

1.14.6 M3000 Filter Error Flowchart

NORMAL

 OPERATIONSYSTEMERRORFIXED? YES NO is displayed. OPERATION

RESUMES

MESSAGE

DISPLAYED

Call an Authorized Repair Technician

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIXTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONSECUTIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FILTER ERROR

 

 

 

 

 

 

 

TECH

 

 

Fryer returns to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cook mode for 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change filter pad and

 

 

 

 

 

 

 

 

 

 

 

 

 

ensure filter pan is

 

 

 

 

 

 

 

 

Fryer returns to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pulled out for a

 

 

 

 

 

 

 

 

cook mode for 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minimum of 30

 

 

 

 

 

 

 

 

minutes or 15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

seconds.

 

 

 

 

 

 

 

 

minutes if pad

 

 

 

 

 

 

 

 

 

 

 

change expired.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the computer displays SERVICE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REQUIRED, the fryer can be used in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

most cases by answering NO when the

This chart follows the process of clearing a filtration

 

 

 

 

prompt

for

SYSTEM

ERROR

issue. The prompt is displayed when any of the

 

 

 

 

FIXED? YES NO is displayed.

The

following occur:

 

 

 

1.

a clogged filter pad,

 

 

 

message repeats every 15 minutes until

 

 

 

the issue is repaired and error cleared by

2.

a tripped or defective filter pump,

 

 

 

a technician.

To clear

the

error,

enter

3.

a leaky O-ring on the pick-up tube,

 

 

 

1111

after

answering

YES

when

4. a failed drain valve/actuator, or

 

 

 

SYSTEM ERROR FIXED? YES

5.

a failed return valve/actuator.

 

 

 

 

 

 

NO is displayed.

 

 

 

 

 

 

 

 

 

 

1-37

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 44
Contents SERVICE AND PARTS MANUAL FRYMASTER BIELA14 SERIES GEN LOV ELECTRIC FRYERemail: service@frymaster.com 8196446NOTICE NOTICENOTICE DANGERDo not use water jets to clean this equipment DANGERDANGERi DANGERA.WARRANTY PROVISIONS - FRYERS B.WARRANTY PROVISIONS - FRYPOTSD.WARRANTY EXCLUSIONS C.PARTS RETURNELECTRICAL POWER SPECIFICATIONS CHAPTER 1: Service Procedures TABLE OF CONTENTSBIELA14 SERIES GEN II LOV ELECTRIC FRYERS BIELA14 SERIES GEN II LOV ELECTRIC FRYERS TABLE OF CONTENTS contCHAPTER 2: Parts List CHAPTER 1: SERVICE PROCEDURES BIELA14 SERIES GEN II LOV ELECTRIC FRYERS1.1 General 1.2 Replacing a Computer3.Remove the two screws from the upper corners of the computer and allow the computer to swing down 1.5 Replacing a Temperature Probe 1.4 Replacing a High-LimitThermostatDANGER 4.Locate the red or yellow and white wires of the temperature probe to be replaced. Note where the leads are connected prior to removing them from the connector. Unplug the 12-pinconnector C-6and using a pin-pusherpush the pins of the temperature probe out of the connector 1.6Replacing a Heating Element Element grounding and wire routing Full vat element wire routingDual vat element wire routing 1.7Replacing Contactor Box Components 1.8 Replacing a Frypot DANGER17.Disconnect the oil return flexlines malfunction DANGER 1.9.3 Replacing the Transformer or Filter Relay 1.10 ATO Automatic Top-offService Procedures 1.10.1 ATO Automatic Top-offTroubleshootingProblem Probable CausesProblem SERVICEProbable Causes Corrective ActionWire 1.10.4 Replacing the ATO Pump Reset SwitchDrain Switch SwitchButtons and LED’s The following buttons are inoperable in auto modeConstant Illumination: Drain open No Illumination: Drain closed1.11.2 MIB Manual Interface Board Troubleshooting ProblemProbable Causes Corrective ActionProblem Probable CausesCorrective Action 1-19Connector Resetting DISPLAYEXPLANATION Drain1.11.7 Control Power Reset Switch 1.11.6 Replacing the MIB Board1.12RTI Service Issues 1.12.1 RTI MIB Tests TroubleshootingWaste full signal AC voltage measurements1.12.2 RTI LOV Wiring 1.12.4 RTI LOV TEST QUICK REFERENCE DISPOSE TO WASTE, REFILL VAT FROM BULKDISPOSE TO WASTE FILL VAT FROM BULKFILL JUG FROM BULK Problem 1.13.1 AIF TroubleshootingCorrective Action Probable CausesWire 1.13.4 Replacing a Linear Actuator 1.13.5 Replacing a Rotary Actuator ProblemRECOVERY FAULTProbable Causes ProblemMISCONFIGURED Corrective ActionCorrective Action ProblemProbable Causes PASSWORDS 1.14.2 M3000 Useful CodesProblem •0469 – Reset FILTER STAT DATA1.14.3 Service Required Errors ERROR MESSAGEEXPLANATION 1-341.14.4 Error Log Codes ERROR MESSAGEEXPLANATION 1-351.14.5 Tech Mode 1.14.6 M3000 Filter Error Flowchart NORMAL ERRORSYSTEM ERROR FIXED? YES OPERATION RESUMES1.14.7 M3000 Menu Summary Tree Adding New Menu ItemsStoring Menu Items in Product Buttons Draining, Refilling, and Disposing of Oil1.14.8 M3000 Board Pin Positions and Harnesses 1.15Loading and Updating Software Procedures SETUP COMPLETE is displayedUNTIL THE DISPLAY PROMPTS TO DO SO IN STEP 24.FILTER NOW YES/NO is displayed1.16 BIELA14 Series LOV Data Network Flowchart 1.17 Interface Board Diagnostic Chart Diagnostic LED LegendPN 826-2260 1-421.18 Probe Resistance Chart Probe Resistance ChartOHMS OHMS1.19 Wiring Diagrams 1.19.1 Component Wiring Domestic1.19.2 Component Wiring CE 1.19.3 Component Wiring CSA 1.19.4 Component Wiring Australia 1.19.5 Contactor Box – Delta Configuration 1.19.6 Contactor Box - WYE Configuration Page Page Page Page Page CHAPTER 2 PARTS LIST AccessoriesITEM PART #ITEM PART #COMPONENT Not illustrated2.3Drain System Components 2.3.1 Drain Tube Sections and Associated PartsPART# ITEM2.3.2.2 Rotary Actuator Drain Valves ITEMPART # COMPONENTPage 2.4.1 Component Boxes cont ITEM PART #boxes COMPONENT2.4.2Contactor Boxes 106-8658 PART #COMPONENT 2.4.3Heating Element Assemblies and Associated Parts 2.4.3.1 Element Assemblies and Hardware 2.4.3.1 Element Assemblies and Hardware cont WYE unitsITEM PART # COMPONENTDUAL-VATELEMENT ASSEMBLY 2.4.3.2 Element Tube AssembliesFULL-VATELEMENT ASSEMBLY 2.4.3.2 Element Tube Assemblies contd 2.4.4Computers ITEM2.4.5Wiring COMPONENT Contactor Box Harness Assembly Dual VatPART # ITEM PART #106-8744 14/17 kW Mechanical ContactorITEM PART #2.4.5.5 Main Wiring Harnesses Filter Pump C2 to Component Box Wiring Harness PART #COMPONENT Full Vat Control Harness J4 to J2 Standard2.4.5.8 M3000, MIB, AIF and ATO Wiring Harnesses Reset Switch 4-5Battery onlyonly ITEMPage 2.5.1 Filtration Components contCOMPONENT ITEM2.5.2.2 Manual Interface Board Assembly ITEM PART #COMPONENT ITEM PART #2.5.2.3 AIF Board Assembly 2.5.2.4 LOV PCB/Computer Board MatrixITEM PART # COMPONENTCOMPONENT See Page 2-5for Drain Valve AssembliesPART # 2.6.2 Frypots with Rotary Actuators ITEMPART # COMPONENT2.7 Oil Return Manifolds 2.8 Return Valves and Associated PartsITEM PART #2.9.2 JIB Cap and Pick Up Assembly 2.8.2 Return Valve Rotary Actuators2.9Auto Top Off Components 2.9.1 JIB Basket PART #2.9.2 JIB Cap and Pick Up Assembly cont 2.9.3 Automatic Top Off Board Assemblyshipping ITEM2.9.4ATO Pump Assembly Domestic UnitsInternational Units ITEMITEM PART #COMPONENT 108-30412.10RTI 2.10.1 RTI Manifold and Accessories 2.10.1 RTI Manifold and Accessories cont ITEMPART # COMPONENT2.10.2RTI Dispose Waste Valve 2.10.3 RTI Test BoxMicroswitch, Gold Sealed Valve, ½” Ball Cover, DV Safety Switch Cover, DV Safety SwitchConnectors and Tools 2.12Fasteners ITEMPART # COMPONENTTHIS PAGE INTENTIONALLY LEFT BLANK SERVICE HOTLINE FAX PartsTech Support 1-800-551-8633