5.When the
If using a filter pad, position the hold |
|
down ring on top of the pad. DO NOT |
|
use filter powder with the pad. | Figure 4 |
6.Replace the crumb tray in the filter pan, then push the filter pan back into the fryer, positioning it all the way to the back of the cabinet.
4.2.2Preparation for Use with the Magnasol Filter Assembly
1.Pull the filter pan out from the cabinet and remove the crumb tray and Magnasol filter assembly. (See Figure 5)
The filter pan is equipped with rollers in rails, much like a kitchen drawer. The pan may be removed for cleaning or to gain access to interior components by lifting the front of the pan to disengage the front rollers, then pulling it forward until the rear rollers clear the rails. The pan cover must not be removed except for cleaning, interior access, or to allow a shortening disposal unit (SDU) to be positioned under the drain.
NOTE: Refer to Section 4.4 for instructions on how to disassemble and reassemble the Magnasol filter screen assembly.
Figure 5
Inspect the filter screen
2.Inspect the fitting on the bottom of the Magnasol filter assembly to ensure that the
3.Inspect the filter pan connection fitting to ensure that both
Figure 6
Inspect the filter connection fitting
Figure 7