Frymaster 8195915 But oil return is very, Slow and bubbling, Oil comes out, Power Shower, From

Page 36

Problem

Probable Causes

Corrective Action

 

 

A. If using filter paper or pad

 

 

configuration, verify that filter

 

 

screen is in bottom of pan with

Filter pump runs,

 

paper or pad on top of screen.

 

 

but oil return is very

A. Improperly installed filter pan

Verify that o-rings are present

slow and bubbling

and in good condition on filter

components.

oil comes out of the

pan connection fitting.

 

Power Shower.

 

If using Magnasol filter

 

 

 

 

assembly, verify that o-ring is

 

 

present and in good condition on

 

 

filter screen fitting.

Problem

Probable Causes

Corrective Action

 

 

B. In order to properly filter, the

 

 

oil or shortening should be at

 

 

or near 350ºF (177ºC). At

 

 

temperatures lower than this,

(continued from

 

the oil/shortening becomes too

B. Attempting to filter with oil or

thick to pass through the filter

previous page)

medium easily, resulting in

shortening that is not hot enough.

 

much slower oil return and

 

 

 

 

eventual overheating of the

 

 

filter pump motor. Make sure

 

 

oil/shortening is at or near

 

 

frying temperature before

 

 

draining oil into filter pan.

 

A. Missing or worn Power Shower

A. Verify that the gasket is present

 

gasket.

and in good condition.

 

 

B. If the Power Shower is not

 

 

cleaned on a routine basis,

 

 

sediment will eventually block

 

 

the small holes around the edges

Power Shower not

 

of the frame. Also, when using

 

solid shortening, if the Power

spraying properly.

B. Clogged openings in Power

Shower is not allowed to drain

 

Shower frame.

completely, the shortening will

 

 

solidify in the holes and may fill

 

 

the frame. Completely drain the

 

 

Power Shower after each

 

 

filtering and clean regularly in

 

 

accordance with the instructions

 

 

in Chapter 5 of this manual.

6-8

Image 36
Contents Hour Service Hotline PRO Series Electric FryersCanada Page Table of Contents Safety Information PRO Series Electric Fryers IntroductionGeneral Computer Information European Community CE Specific InformationService Information PRO Series Electric Fryers Installation Instructions Australia AWGPage Page Equipment Setup and Shutdown Procedures SetupPRO Series Electric Fryers Operating Instructions Shutdown ControllersPage PRO Series Electric Fryers Filtration Instructions Page Preparation for Use with Filter Paper or Filter Pad Preparation for Use with the Magnasol Filter Assembly Use filter powder with the padPage Snap the Power Shower into position Filter Pump Reset Switch Cleaning ReassemblyDraining and Disposing of Waste Oil PRO Series Electric Fryers Preventative Maintenance Gasket Page Annual/Periodic System Inspection FryerBuilt-In Filtration System Page PRO Series Electric Fryers Operator Troubleshooting IntroductionTroubleshooting Control and Heating Problems Controller wontActivate Fryer does not heatWhen first started Heat indicator onFryer repeatedly Cycles on and offError Messages and Display Problems Temperature is CM III frypotDisplayed constantly Temperature scale Heating mode lightDigital controller Display is in wrongBasket Lift Problems Filtration ProblemsPower Shower Power Shower notBut oil return is very Slow and bubblingThis page Intentionally Left Blank Service Hotline