Frymaster 8195915 operation manual

Page 28

Verify that all O-rings and seals (including those on the Power Shower and on quick-disconnect fittings) are present and in good condition. Replace o-rings and seals if worn or damaged.

Check filtration system integrity as follows:

Verify that filter pan cover is present and properly installed.

With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the cooking oil/shortening (or that gurgling is heard from the Power Shower port) of the associated frypot..

Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot (or no gurgling should be heard from the Power Shower ports).

Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all cooking oil/shortening to return to the frypot (indicated by bubbles in the cooking oil/shortening or, on units with Power Showers, cessation of oil flow from the Power Shower). Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

5-5

Image 28
Contents Hour Service Hotline PRO Series Electric FryersCanada Page Table of Contents PRO Series Electric Fryers Introduction Safety InformationGeneral Computer Information European Community CE Specific InformationService Information PRO Series Electric Fryers Installation Instructions Australia AWGPage Page Setup Equipment Setup and Shutdown ProceduresPRO Series Electric Fryers Operating Instructions Shutdown ControllersPage PRO Series Electric Fryers Filtration Instructions Page Preparation for Use with Filter Paper or Filter Pad Preparation for Use with the Magnasol Filter Assembly Use filter powder with the padPage Snap the Power Shower into position Filter Pump Reset Switch Cleaning ReassemblyDraining and Disposing of Waste Oil PRO Series Electric Fryers Preventative Maintenance Gasket Page Fryer Annual/Periodic System InspectionBuilt-In Filtration System Page PRO Series Electric Fryers Operator Troubleshooting IntroductionTroubleshooting Control and Heating Problems Controller wontActivate Fryer does not heatWhen first started Heat indicator onFryer repeatedly Cycles on and offError Messages and Display Problems CM III frypot Temperature isDisplayed constantly Temperature scale Heating mode lightDigital controller Display is in wrongBasket Lift Problems Filtration ProblemsPower Shower Power Shower notBut oil return is very Slow and bubblingThis page Intentionally Left Blank Service Hotline