DANGER

Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over, and cause injury. The appliance area must be kept free and clear of combustible material at all times.

All installation and service on FRYMASTER equipment must be performed by qualified, certified, licensed, and/or authorized installation or service personnel.

Service may be obtained by contacting your local Factory Authorized Service Center.

In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the power switch OFF. Do not attempt to start the fryer(s) until power is restored.

This appliance must be kept free and clear of combustible material, except that it may be installed on combustible floors.

A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for servicing and proper operation.

In Australia

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations.

WARNING

Do not block the area around the base or under the fryers.

2.2Power Requirements

MODEL

VOLTAGE

PHASE

WIRE

MINIMUM WIRE

AMPS

 

SIZE

SERVICE

 

(per leg)

 

 

 

AWG

(mm)

 

 

 

 

 

FPPH14

208

Single

3

3

(5.83)

68

FPPH14

208

3

3

6

(4.11)

39

FPPH14

240

Single

3

4

(5.19)

59

FPPH14

240

3

3

6

(4.11)

34

FPPH14

480

Single

3

8

(3.26)

30

FPPH14

480

3

3

8

(2.59)

17

FPPH14

220/380

3

4

6

(4.11)

21

FPPH14

240/415

3

4

6

(4.11)

20

FPPH14

230/400

3

4

6

(4.11)

21

FPPH17

208

3

3

6

(4.11)

48

FPPH17

240

3

3

6

(4.11)

41

FPPH17

480

3

3

6

(4.11)

21

FPPH17

220/380

3

4

6

(4.11)

26

FPPH17

240/415

3

4

6

(4.11)

24

FPPH17

230/400

3

4

6

(4.11)

25

FPPH22

208

3

3

4

(5.19)

61

FPPH22

240

3

3

4

(5.19)

53

FPPH22

480

3

3

6

(4.11)

27

FPPH22

220/380

3

4

6

(4.11)

34

FPPH22

240/415

3

4

6

(4.11)

31

FPPH22

230/400

3

4

6

(4.11)

32

2-2

Image 9
Contents PRO Series Electric Fryers Hour Service HotlineCanada Page Table of Contents Safety Information PRO Series Electric Fryers IntroductionGeneral European Community CE Specific Information Computer InformationService Information PRO Series Electric Fryers Installation Instructions AWG AustraliaPage Page Equipment Setup and Shutdown Procedures SetupPRO Series Electric Fryers Operating Instructions Controllers ShutdownPage PRO Series Electric Fryers Filtration Instructions Page Preparation for Use with Filter Paper or Filter Pad Use filter powder with the pad Preparation for Use with the Magnasol Filter AssemblyPage Snap the Power Shower into position Filter Pump Reset Switch Reassembly CleaningDraining and Disposing of Waste Oil PRO Series Electric Fryers Preventative Maintenance Gasket Page Annual/Periodic System Inspection FryerBuilt-In Filtration System Page Introduction PRO Series Electric Fryers Operator TroubleshootingController wont Troubleshooting Control and Heating ProblemsActivate Fryer does not heatHeat indicator on When first startedFryer repeatedly Cycles on and offError Messages and Display Problems Temperature is CM III frypotDisplayed constantly Heating mode light Temperature scaleDigital controller Display is in wrongFiltration Problems Basket Lift ProblemsPower Shower not Power ShowerBut oil return is very Slow and bubblingThis page Intentionally Left Blank Service Hotline