Frymaster 8195915 operation manual CM III frypot, Temperature is, Displayed constantly

Page 33

Problem

Probable Causes

Corrective Action

 

 

This display is normal if the fryer

 

 

setpoint has been changed to a

 

 

lower temperature. The display

 

 

should revert to the normal four

CM III display

Fryer is more than 21ºF (12ºC) above

dashes when the frypot

shows .

setpoint.

temperature cools to the setpoint.

If the setpoint has not been

 

 

 

 

changed, this indicates a problem

 

 

with the temperature control

 

 

circuitry. Turn the fryer off and

 

 

call FASC.

 

 

This in an indication of a

CM III display

Frypot temperature is more than

malfunction in the temperature

control circuitry, including a

410ºF (210ºC) or, in CE countries,

shows .

failure of the high limit thermostat.

395ºF (202ºC).

 

Shut the fryer down immediately

 

 

 

 

and call FASC.

 

 

This display is normal when the

 

 

fryer is first turned on and may

 

 

appear for a short while if a large

 

 

batch of frozen product is added to

 

 

the frypot. If the display never

 

 

goes out, the fryer is not heating.

CM III display

 

Look for a decimal in the LED

Frypot temperature is more than 21ºF

display between digits 1 and 2. If

shows .

(12ºC) below setpoint.

the decimal is present, the

 

 

computer is calling for heat and is

 

 

functioning properly. See Fryer

 

 

Does Not Heat in Control and

 

 

Heating Problems (Section 6.2.1).

 

 

If the decimal is not present, the

 

 

computer is not calling for heat and

 

 

may be malfunctioning

 

 

This indicates a problem within the

CM III display

Problem with the temperature

temperature measuring circuitry

measuring circuitry including the

that is beyond the scope of

shows .

probe.

operator troubleshooting. Shut the

 

 

 

fryer down and call FASC.

 

 

The CM III computer may be

 

 

programmed for constant

CM III frypot

 

temperature display or countdown

Computer is programmed for

timer display. Refer to the separate

temperature is

constant temperature display.

Frymaster Fryer Controllers

displayed constantly.

 

User's Manual for instructions on

 

 

 

 

toggling between these display

 

 

options.

6-5

Image 33
Contents PRO Series Electric Fryers Hour Service HotlineCanada Page Table of Contents Safety Information PRO Series Electric Fryers IntroductionGeneral European Community CE Specific Information Computer InformationService Information PRO Series Electric Fryers Installation Instructions AWG AustraliaPage Page Equipment Setup and Shutdown Procedures SetupPRO Series Electric Fryers Operating Instructions Controllers ShutdownPage PRO Series Electric Fryers Filtration Instructions Page Preparation for Use with Filter Paper or Filter Pad Use filter powder with the pad Preparation for Use with the Magnasol Filter AssemblyPage Snap the Power Shower into position Filter Pump Reset Switch Reassembly CleaningDraining and Disposing of Waste Oil PRO Series Electric Fryers Preventative Maintenance Gasket Page Annual/Periodic System Inspection FryerBuilt-In Filtration System Page Introduction PRO Series Electric Fryers Operator TroubleshootingController wont Troubleshooting Control and Heating ProblemsActivate Fryer does not heatHeat indicator on When first startedFryer repeatedly Cycles on and offError Messages and Display Problems Temperature is CM III frypotDisplayed constantly Heating mode light Temperature scaleDigital controller Display is in wrongFiltration Problems Basket Lift ProblemsPower Shower not Power ShowerBut oil return is very Slow and bubblingThis page Intentionally Left Blank Service Hotline