Problem | Probable Causes | Corrective Action | |
Fryer heats until |
| Call FASC. | |
high limit trips | Contactor or controller has failed. |
| |
without heat |
| ||
|
| ||
indicator ON. |
|
| |
Fryer stops heating |
| Determining which component has | |
The high limit thermostat or | failed is beyond the scope of | ||
with heat indicator | |||
contactor has failed. | operator troubleshooting. Call | ||
ON. | |||
| FASC. | ||
|
| ||
6.2.2 Error Messages and Display Problems |
|
Problem
Probable Causes
Corrective Action
|
| Verify that the drain valve is fully | |
|
| closed. The fryer will not function | |
Basket lift timer |
| if the drain valve is not fully | |
Open drain valve or problem with | closed. If the drain valve is fully | ||
display shows | |||
latching circuits | closed, the problem is within the | ||
. | |||
| latching circuitry and is beyond the | ||
|
| ||
|
| scope of operator trouble shooting. | |
|
| Call FASC. | |
|
| This in an indication of a | |
Basket lift timer | Frypot temperature is more than | malfunction in the temperature | |
control circuitry, including a | |||
410ºF (210ºC) or, in CE countries, | |||
display shows . | failure of the high limit thermostat. | ||
395ºF (202ºC). | |||
| Shut the fryer down immediately | ||
|
| ||
|
| and call FASC. | |
Basket lift timer |
| This indicates a problem within the | |
Problem with the temperature | temperature measuring circuitry | ||
display shows | measuring circuitry including the | that is beyond the scope of | |
. | probe. | operator troubleshooting. Shut the | |
|
| fryer down and call FASC. | |
|
| CM III computers may be | |
CM III display is in |
| programmed to display in either | |
| Fahrenheit or Celsius. Refer to the | ||
wrong temperature |
| ||
Incorrect display option programmed. | separate Frymaster Fryer | ||
scale (Fahrenheit or | |||
| Controllers User's Manual for | ||
Celsius). |
| ||
| instructions on changing the | ||
|
| ||
|
| display. | |
|
| Verify that the drain valve is fully | |
|
| closed. The fryer will not function | |
CM III display |
| if the drain valve is not fully | |
Open drain valve or problem with | closed. If the drain valve is fully | ||
shows . | latching circuitry. | closed, the problem is within the | |
|
| latching circuitry and is beyond the | |
|
| scope of operator trouble shooting. | |
|
| Call FASC. |