Check the cooktop serial plate to see if the cooktop is approved for installation in mobile homes and/or recreational park trailers. Serial plate is located on the bottom of the unit.

If approved, the following items are applicable:

Mobile Homes

The installation of a range designed for mobile home installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Standard for Mobile Home Construction and Safety, Title 24 HUD, (Part 280)] or, when such standard is not applicable, the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A, or with local codes.

In Canada the range must be installed in accordance with the current CSA Standard C22.1 -- Canadian Electrical Code Part 1 and Section Z240.4.1 -- Installation Requirements for Gas Burning Appliances in Mobile Homes (CSA Standard CAN/CSA -- Z240MH).

Recreational Park Trailers

The installation of a range designed for recreational park trailers must conform with state or other codes or, in the absence of such codes, with the Standard for Recreational Park Trailers, ANSI A119.5-latest edition.

In Canada the range must be installed in accordance with CAN/CSA -- Z240.6.2 -- Electrical Requirements for R.V.’s (CSA Standard CAN/CSA -- Z240 RV Series) and Section Z240.4.2 -- Installation Requirements for Propane Appliances and Equipment in R.V.’s (CSA Standard CAN/CSA -- Z240 RV Series).

Installation Of Appliance

The installation of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1--Latest Edition, or, in Canada, CAN/CGA-B149 Installation Code, Latest Edition.

This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA No. 70--Latest Edition, or, in Canada, current CSA Standard C22.1 Canadian Electrical Code, Part 1.

In The Commonwealth Of Massachusetts

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.

A “T” handle type manual gas valve must be installed in the gas supply line to this appliance.

A flexible gas connector, when used, must not exceed a length of three (3) feet / 36 inches.

All supply piping, except as noted, should use common National Pipe Thread (N.P.T.). For all pipe connections use an approved pipe joint compound resistant to the action of LP gas.

CAUTION: Warranty is void on Maytag equipment installed other than as recommended by manufacturer.

This appliance is designed for use with the appliance gas pressure regulator supplied with this appliance. It must be installed in the gas line ahead of the gas manifold entrance. It is preset for use with natural gas and must be converted, as described on pages 7 and 8, for use with LP gas. (See figures 6 -- 11).

This appliance is designed to operate at a pressure of 5 inches of water column (36″ models), 4 inches of water column (30″ models) on natural gas or, if converted for use with LP gas (propane or butane), 10 inches water column. Make sure this appliance is supplied with and adjusted for the type of gas for which it is designed.

This appliance was adjusted at the factory for use with natural gas. If, at any time, this appliance is to be used with a different type of gas, all of the conversion adjustments described on pages 7 and 8 must be made by a qualified service technician before attempting to operate the cooktop on that gas. Natural gas should be supplied to the appliance pressure regulator at a line pressure between 6 and 14 inches of water column or, if converted for LP gas, between 11 and 14 inches.

WARNING

If the line pressure supplying the appliance pressure regulator exceeds 14″ water column (any gas), an external regulator must be installed in the gas line ahead of the appliance regulator to reduce the pressure to no more than 14″ water column. Failure to do this can result in malfunction and damage to the appliance.

Insure this appliance is adjusted for the type of gas supplied to it and that the gas supply pressure to the appliance regulator is within the proper pressure range.

NOTE: In Canada, gas utilization codes prohibit use of street elbows. Use standard pipe elbows and make modifications to these instructions as necessary.

3

Image 3
Contents Inches Cutout Dimensions Are CriticalDimensions W10187822Preparation Of Countertop Required Adjustments At Time Of InstallationInstalling Cabinetry Over Your Cooktop Location Of Your ApplianceCommonwealth Of Massachusetts Installation Of ApplianceMobile Homes Recreational Park TrailersConnecting Appliance To Gas Supply If no Other Appliance is to be Installed below this CooktopIllustrative GAS Supply Piping Illustrative Alternative Piping Pressure TestingElectrical Grounding Instructions Electrical Wiring InformationReplace ALL Orifice Spuds Installation Of LP Orifice SpudConverting Appliance For Use With LP Gas Removal of Orifice SpudLOW Flame Adjustment See figure Conversion of Appliance Pressure RegulatorInvert CAP in Appliance Pressure Regulator See figure Burner Model 36″ Wide Burner Model 30″ Wide Installation Of Natural Gas Orifice SpudsReset the Valves for Natural GAS To Convert Appliance For Use With Natural Gas30″ Cooktop Burner PerformanceBurner Model 36″ Wide 36″ CooktopHow To Remove Cooktop For Servicing Service-Parts InformationHolding Unit Down To Countertop Dimensiones 30 yPulgadas Sugerencias importantes de preparación Ajustes necesarios al momento de la instalaciónUbicación de su electrodoméstico Preparación de la superficie para cocinarEn la Commonwealth de Massachusetts Casas móvilesRemolques de recreación Instalación del electrodomésticoIlustración DE LA Tubería DE Suministro DE GAS Conexión del electrodoméstico al suministro de gasIlustración DE LA Tubería Alternativa Pruebas de presiónInstrucciones eléctricas de conexión Tierra Información de alambrado eléctricoPara Quitar LA Copa DE Orificio Instalación de la copa de orificio LPReemplace Todas LAS Copas DE Orificio Ajuste DE LA Llama Baja Vea la figura Conversión DELRegulador DE Presión Inversión DE LA Tapa DEL Regulador DE Presión Vea la figuraInstalación de las copas de orificio de gas Natural Invierta LA Tapa DEL Regulador DE PRESIÓN. Vea la figuraReajuste LAS Válvulas Para GAS Natural Aviso de altitud Desempeño de los quemadores36″ Modelo 30″ ModeloPara sujetar la unidad al mostrador Cómo quitar la superficie para cocinar para darle servicioInformación de las piezas de servicio Pouces Po et 30 poSuggestions importantes pour la préparation Emplacement de votre appareil ménagerRéglages requis lors de la mise en service Préparation du comptoirDans le Commonwealth du Massachusetts Maisons mobilesRoulottes de parc Pose de l’appareilIllustration D’UNE Conduite DE GAZ Raccordement de l’appareil à l’alimentation en gazIllustration D’UNE Méthode Alternative Vérification de la pressionMise à la terre Câblage électriqueRemplacer Tous LES Raccords À Orifice Conversion de l’appareil au gaz GPLDépose DE L’ÉCROU À Orifice Pose de l’écrou à orifice pour gaz GPLRéglage DE LA Flamme À FEU Doux Voir figure Conversion DUDétendeur DE L’APPAREIL Inverser LE Capuchon Dans LE DétendeurInverser LE Capuchon Dans LE Détendeur voir la figure Régler LES Boutons DE Commande AU GAZ NaturelPour convertir l’appareil au gaz naturel Pose de raccords à orifice pour gaz naturelModèle À 30 PO 76,2 CM Débits DE GAZ GAZ NATUREL/GPL BTU/H Emplacement DU BrûleurFonctionnement des brûleurs Modèle À 36 PO 91,4 CMInformations sur les pièces de rechange Fixation de l’appareil au comptoir