Connecting Appliance To Gas Supply
A QUALIFIED SERVICE TECHNICIAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION. Leak testing of the appliance shall be conducted by the installer according to the instructions given.
Gas supply piping MUST conform to all local, municipal and state building codes and local utility regulations.
IF NO OTHER APPLIANCE IS TO BE INSTALLED BELOW THIS COOKTOP
Join the appliance pressure regulator supplied with this appliance to the entrance threads of the Gas Manifold. The appliance regulator is marked with a directional arrow indicating correct direction of gas flow. Ensure the appliance regulator is installed with the arrow pointing toward the gas manifold entrance. Tighten the appliance regulator to 20 to 30
I M P O R T A N T
Never tighten to more than 35
Install the appliance in its counter cutout.
Make the gas connection to the inlet of the appliance pressure regulator with 1/2″ NPT male pipe threads.
Install a manual
Make additional pipe connections as necessary ahead of the
I M P O R T A N T
Apply a
ILLUSTRATIVE GAS SUPPLY PIPING
(3/8″ N.P.T.)
ALL SUPPLY SIDE
PIPE JOINTS
1/2″ N.P.T.
FIGURE 3
WARNING
Gas leaks may occur in your system and result in a dangerous situation. Gas leaks may not be detected by smell alone. Gas suppliers recommend you purchase and install an UL approved gas detector. Install and use in accordance with the manufacturer’s instructions.