Magic Chef W10187822 installation manual To Convert Appliance For Use With Natural Gas

Page 9

To Convert Appliance For Use With Natural Gas

WARNING

Electrical power and gas must be turned off prior to conversion.

If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas.

A. REPLACE ALL ORIFICE SPUDS.

1.Perform Steps 1 and 2 on page 7.

2.Perform Step 3 on page 7.

3.For Step 4: Locate the brass natural gas orifice spuds that were originally installed in this appliance before its conversion for use with LP gas. Observe the number on each of the spuds and note the correct burner location for each spud as shown in figures 13 and 14.

Installation Of Natural Gas Orifice Spuds

5 BURNER MODEL (36WIDE)

4 BURNER MODEL (30WIDE)

1.55

1.55

 

1.55

1.85

FIGURE 14

 

4.Complete Steps 5, 6 and 7 on page 7 to complete the installation of natural gas main spuds in their correct locations.

5.Save the orifices removed from the appliance for future use. They will be needed if this appliance is again converted for use with LP gas.

1.55

1.42

1.42

FIGURE 13

1.42B. INVERT CAP IN APPLIANCE PRESSURE REGULATOR. (See figure 10).

With the appliance installed the appliance regulator should be located as shown in either figure 3 or 4 (pages 4 & 5). Identify the type of appliance regulator and follow the instructions in the appropriate illustration.

C. RESET THE VALVES FOR NATURAL GAS

1.Light one burner, and set on low.

2.Remove the knob.

3.Remove the rubber grommets.

4.Locate the valve adjustment screw. See figure 11.

1.615. Insert a slender, thin-blade screwdriver into knob hole and engage blade with slot in adjusting screw.

6.Starting from the LP position (see #5 on page 8, under C. LOW FLAME ADJUSTMENT), turn the screw counter clockwise until the flame stabilizes and matches the pictured “low” setting on figure 12. Proper adjustment will produce a stable, steady blue flame of minimum size. The final adjustment should be checked by turning the knob from high to low several times without extinguishing the flame.

After Steps A, B and C have been completed, check the appearance of each burner’s flame at the Hi and Lo settings against figure 12. If the flames appear too large or too small, make sure all steps were completed correctly.

9

Image 9
Contents Dimensions Cutout Dimensions Are CriticalW10187822 InchesInstalling Cabinetry Over Your Cooktop Required Adjustments At Time Of InstallationLocation Of Your Appliance Preparation Of CountertopMobile Homes Installation Of ApplianceRecreational Park Trailers Commonwealth Of MassachusettsConnecting Appliance To Gas Supply If no Other Appliance is to be Installed below this CooktopIllustrative GAS Supply Piping Illustrative Alternative Piping Pressure TestingElectrical Grounding Instructions Electrical Wiring InformationConverting Appliance For Use With LP Gas Installation Of LP Orifice SpudRemoval of Orifice Spud Replace ALL Orifice SpudsLOW Flame Adjustment See figure Conversion of Appliance Pressure RegulatorInvert CAP in Appliance Pressure Regulator See figure Reset the Valves for Natural GAS Installation Of Natural Gas Orifice SpudsTo Convert Appliance For Use With Natural Gas Burner Model 36″ Wide Burner Model 30″ WideBurner Model 36″ Wide Burner Performance36″ Cooktop 30″ CooktopHow To Remove Cooktop For Servicing Service-Parts InformationHolding Unit Down To Countertop Dimensiones 30 yPulgadas Ubicación de su electrodoméstico Ajustes necesarios al momento de la instalaciónPreparación de la superficie para cocinar Sugerencias importantes de preparaciónRemolques de recreación Casas móvilesInstalación del electrodoméstico En la Commonwealth de MassachusettsIlustración DE LA Tubería DE Suministro DE GAS Conexión del electrodoméstico al suministro de gasIlustración DE LA Tubería Alternativa Pruebas de presiónInstrucciones eléctricas de conexión Tierra Información de alambrado eléctricoPara Quitar LA Copa DE Orificio Instalación de la copa de orificio LPReemplace Todas LAS Copas DE Orificio Regulador DE Presión Conversión DELInversión DE LA Tapa DEL Regulador DE Presión Vea la figura Ajuste DE LA Llama Baja Vea la figuraInstalación de las copas de orificio de gas Natural Invierta LA Tapa DEL Regulador DE PRESIÓN. Vea la figuraReajuste LAS Válvulas Para GAS Natural 36″ Modelo Desempeño de los quemadores30″ Modelo Aviso de altitudPara sujetar la unidad al mostrador Cómo quitar la superficie para cocinar para darle servicioInformación de las piezas de servicio Pouces Po et 30 poRéglages requis lors de la mise en service Emplacement de votre appareil ménagerPréparation du comptoir Suggestions importantes pour la préparationRoulottes de parc Maisons mobilesPose de l’appareil Dans le Commonwealth du MassachusettsIllustration D’UNE Conduite DE GAZ Raccordement de l’appareil à l’alimentation en gazIllustration D’UNE Méthode Alternative Vérification de la pressionMise à la terre Câblage électriqueDépose DE L’ÉCROU À Orifice Conversion de l’appareil au gaz GPLPose de l’écrou à orifice pour gaz GPL Remplacer Tous LES Raccords À OrificeDétendeur DE L’APPAREIL Conversion DUInverser LE Capuchon Dans LE Détendeur Réglage DE LA Flamme À FEU Doux Voir figurePour convertir l’appareil au gaz naturel Régler LES Boutons DE Commande AU GAZ NaturelPose de raccords à orifice pour gaz naturel Inverser LE Capuchon Dans LE Détendeur voir la figureFonctionnement des brûleurs Débits DE GAZ GAZ NATUREL/GPL BTU/H Emplacement DU BrûleurModèle À 36 PO 91,4 CM Modèle À 30 PO 76,2 CMInformations sur les pièces de rechange Fixation de l’appareil au comptoir