Hoshizaki KM-630MAH, KM-630MWH, KM-630MRH service manual

Page 62

9)Attach compressed air or carbon dioxide supply to the Condenser Water Line Drain Valve.

10)Quickly blow the water-cooled Condenser out, using compressed air or carbon

[2]Remove the water from the potable water supply line:

1)Remove the Front Panel. (Except water-cooled model)

2)Move the Control Switch, on the Control Box, to the “OFF” position.

3)Wait 3 minutes.

4)Close the Potable Water Supply Line Shut-off Valve and open the Potable Water Supply Line Drain Valve.

5)Allow the line to drain by gravity.

6)Attach compressed air or carbon dioxide supply to the Potable Water Line Drain Valve.

7)Move the Control Switch to the “ICE” position.

8)Blow the potable water line out using compressed air or carbon dioxide.

[3]Drain the Potable Water Tank:

1)Turn off the power supply.

2)Move the Control Switch to the “OFF” position.

3)Drain the Water Tank by removing the base cover and one end of the pump tubing. See Fig. 4.

4)Replace the removed parts in their correct

positions.

Fig. 4

5)Remove all ice from the Storage Bin, and clean the Storage Bin.

6)Replace the Front Panel in its correct position.

7)Close the Drain Valve.

62

Image 62
Contents KM-630MAH KM-630MWH KM-630MRH Hoshizaki AMERICA, INC Contents Maintenance Specifications KM-630MAH Water TEMP. F2a. KM-630MWH Serial #L00001D M20270B 2b. KM-630MWH Serial #M20301E KM-630MRH Condenser Unit URC-6FSpecifications II. General Information Construction KM-630MAHKM-630MWH KM-630MRH SOLID-STATE Control Features of Control Products E Controller BoardController Board Controller BoardPage Harvest Cycle Beep every 3 sec. = High Evaporator Temperature 127 FMinute Fill Cycle Freeze CycleControl Products HOS-001A Board Sequence 1st Cycle Important Water Valve opening is limited to 6 minutes2nd Cycle and after with pump drain 2nd Cycle and after with no pump drain Controls and Adjustments For Models with ThermostatPage Setting Time Models with Thermostat Models with Mechanical BIN Control Checking the Controller BoardExplanation of Operation Proximity SwitchMechanical BIN Control Troubleshooting Mechanical BIN Control only KM-630MAH KM-630MWH KM-630MRH Wiring Diagrams Page B1 KM-630MRH with auxiliary codes L-0, M-0, M-1 B2 KM-630MRH with auxiliary codes M-2 and after Timing Chart Page Performance Data 157B1 KM-630MWH Serial #L00001D M20270B Pressure Drop of Cooling Water LineB2 KM-630MWH Serial #M20301E 603 IV. Service Diagnosis 1. no ICE Production Problem Possible Cause RemedyController Board Problem Possible Cause Remedy Evaporator is Frozen UP ThermistorOthers LOW ICE ProductionAbnormal ICE Refrigerant Recovery Removal and Replacement of ComponentsService for Refrigerant Lines Evacuation and Recharge R-404ABrazing Removal and Replacement of Compressor Important Page Removal and Replacement of Drier Removal and Replacement of Expansion ValveRemoval and Replacement of HOT GAS Valve and Line Valve Page Removal and Replacement of Evaporator Important Page Adjustment of Water Regulating Valve WATER-COOLED Model only Page Removal and Replacement of Thermistor Caution Removal and Replacement of FAN Motor Removal and Replacement of Water Valve Removal and Replacement of Pump MotorRemoval and Replacement of Spray Tubes VI. Cleaning and Maintenance Instructions Preparing the Icemaker for Long StoragePage Cleaning and Sanitizing Procedures Cleaning Procedure Page Sanitizing Procedure Maintenance