SETTING |
| FREQUENCY | |
Dip Switch | Dip Switch |
| |
No. 5 |
| No. 6 |
|
OFF |
| OFF | every cycle |
ON |
| OFF | every 2 cycles |
OFF |
| ON | every 5 cycles |
ON |
| ON | every 10 cycles |
5) Freeze Timer
CAUTION
Adjust to proper specification, or the unit may not operate correctly.
Two new dip switches numbered 9 and 10 have been added to the improved “E” board to better prevent possible freeze ups. These settings come factory set to the default setting of 60 min. (OFF, OFF). Check the adjustment chart published in the Tech Specs for proper settings. If the old board does not have these two dip switches, (only 8 instead of 10), leave setting as OFF, OFF.
SETTING |
| TIME | |
Dip Switch | Dip Switch |
| |
No. 9 |
| No. 10 |
|
OFF |
| OFF | 60 min. |
ON |
| OFF | 70 min. |
OFF |
| ON | 50 min. |
ON |
| ON | 60 min. |
6) Bin Control
MODELS WITH THERMOSTAT
CAUTION
When the ambient temperature is below 45°F, the Bin Control Thermostat operates to stop the icemaker even if the Ice Storage Bin is empty. When the Thermostat is set in the prohibited range, the icemaker operates con- tinuously even if the Ice Storage Bin is filled with ice. Setting in the prohib- ited range might cause severe damage to the icemaker resulting in failure.
No adjustment is required under normal use, as the Bin Control is
24