Hoshizaki KM-630MRH, KM-630MWH, KM-630MAH service manual Problem Possible Cause Remedy

Page 43

PROBLEM

POSSIBLE CAUSE

 

REMEDY

[5] No water

a) Water Supply Line

1.

Water pressure too low and

1.

Check and get

comes from

 

 

 

water level in Water Tank

 

recommended pressure.

Spray Tubes.

 

 

 

too low.

 

 

Water Pump

 

 

 

 

 

 

b) Water Solenoid

1.

Dirty mesh filter or orifice

1.

Clean.

will not start, or

Valve

 

 

and water level in Water

 

 

freeze cycle

 

 

 

Tank too low.

 

 

time is too

c) Water System

1.

Water leaks.

1.

Check connections for

short.

 

 

 

 

 

water leaks, and replace.

 

 

 

2. Clogged.

2.

Clean.

 

d) Pump Motor

 

1. Motor winding opened.

1. Replace.

 

 

 

2.

Bearing worn out.

2. Replace.

 

 

3.

Wiring to Pump Motor.

3.

Check for loose

 

 

 

 

 

 

connection or open, and

 

 

 

 

 

 

replace.

 

 

 

 

 

 

 

 

4.

Defective Capacitor.

4.

Replace.

 

 

5.

Defective or bound impeller.

5. Replace and clean.

 

 

6.

Mechanical Seal worn out.

6.

Check and replace.

 

e) Controller Board

1.

Defective.

1.

See “II.2. [e] CHECKING

 

 

 

 

 

 

CONTROLLER BOARD.”

[6] Fan Motor will

a) Fan Motor

 

1. Motor winding opened.

1. Replace.

not start, or is

 

2.

Bearing worn out.

2.

Replace.

not operating.

 

 

 

 

 

 

 

3.

Wiring to Fan Motor.

3.

Check for loose

 

 

 

 

 

 

connection or open, and

 

 

 

 

 

 

replace.

 

 

4.

Defective Capacitor.

4.

Replace

 

 

 

5. Fan blade bound.

5.

Check and replace.

 

b) Controller Board

1.

Defective.

1.

See “II.2. [e] CHECKING

 

 

 

 

 

 

CONTROLLER BOARD.”

[7] All components

a) Refrigerant

 

1. Undercharged.

1. Check for leaks and

run but no ice

 

 

 

 

 

recharge.

is produced.

 

 

 

 

 

 

 

2.

Air or moisture trapped.

2.

Replace Drier, and

 

 

 

 

 

 

recharge.

 

b) Compressor

1.

Defective valve.

1. Replace.

 

c) Hot Gas Solenoid

1.

Continues to open in freeze

1.

Check and replace.

 

Valve

 

 

cycle.

 

 

 

d) Line Valve

1.

Continues to close in

1.

Check and replace

 

 

 

 

freeze cycle.

 

 

 

e) Water Supply Line

 

1. Condenser water pressure

1.

Check and get

 

[Water-cooled model

 

 

too low or off and Pressure

 

recommended pressure.

 

only]

 

 

Control opens and closes

 

 

 

 

 

 

frequently.

 

 

 

 

 

 

 

 

 

43

Image 43
Contents KM-630MAH KM-630MWH KM-630MRH Hoshizaki AMERICA, INC Contents Maintenance Water TEMP. F Specifications KM-630MAH2a. KM-630MWH Serial #L00001D M20270B 2b. KM-630MWH Serial #M20301E KM-630MRH URC-6F Condenser UnitSpecifications KM-630MAH II. General Information ConstructionKM-630MWH KM-630MRH Controller Board Features of Control Products E Controller BoardController Board SOLID-STATE ControlPage Freeze Cycle Beep every 3 sec. = High Evaporator Temperature 127 FMinute Fill Cycle Harvest CycleControl Products HOS-001A Board Important Water Valve opening is limited to 6 minutes Sequence 1st Cycle2nd Cycle and after with pump drain 2nd Cycle and after with no pump drain For Models with Thermostat Controls and AdjustmentsPage Setting Time Models with Thermostat Checking the Controller Board Models with Mechanical BIN ControlMechanical BIN Control Proximity SwitchExplanation of Operation Troubleshooting Mechanical BIN Control only KM-630MAH KM-630MWH KM-630MRH Wiring Diagrams Page B1 KM-630MRH with auxiliary codes L-0, M-0, M-1 B2 KM-630MRH with auxiliary codes M-2 and after Timing Chart Page 157 Performance DataPressure Drop of Cooling Water Line B1 KM-630MWH Serial #L00001D M20270BB2 KM-630MWH Serial #M20301E 603 Problem Possible Cause Remedy IV. Service Diagnosis 1. no ICE ProductionController Board Problem Possible Cause Remedy Thermistor Evaporator is Frozen UPAbnormal ICE LOW ICE ProductionOthers Evacuation and Recharge R-404A Removal and Replacement of ComponentsService for Refrigerant Lines Refrigerant RecoveryBrazing Removal and Replacement of Compressor Important Page Removal and Replacement of Expansion Valve Removal and Replacement of DrierRemoval and Replacement of HOT GAS Valve and Line Valve Page Removal and Replacement of Evaporator Important Page Adjustment of Water Regulating Valve WATER-COOLED Model only Page Removal and Replacement of Thermistor Caution Removal and Replacement of FAN Motor Removal and Replacement of Pump Motor Removal and Replacement of Water ValveRemoval and Replacement of Spray Tubes Preparing the Icemaker for Long Storage VI. Cleaning and Maintenance InstructionsPage Cleaning and Sanitizing Procedures Cleaning Procedure Page Sanitizing Procedure Maintenance